• Title/Summary/Keyword: Wear area

Search Result 540, Processing Time 0.03 seconds

A Comparative Study on the Evaluation of the Wear Resistance in Zr-xNb-xSn Alloys

  • Lee, Young-Ho;Kim, Hyung-Kyu;Jung, Youn-Ho
    • KSTLE International Journal
    • /
    • v.4 no.2
    • /
    • pp.47-51
    • /
    • 2003
  • Sliding wear tests have been carried out in room temperature air and water in order to compare the wear resistance of Zr-xNb-xSn alloys of various alloying elements (Nb and Sn). The main focus was to quantitatively compare the wear properties of the recently developed Zr-xNb-xSn alloys with the commercial ones using the evaluation parameters of the wear resistance with the consideration of the worn area. As a result, the recently developed alloys had a similar wear resistance compared with the commercial ones. The dominant factor governing the wear resistance was the protruded volume of the wear debris that was formed on the worn area in the air condition, but the accommodation of the plastic deformation on the contact area in water. In addition, the worn area size appeared to be very different depending on the tested alloys. To evaluate the wear resistance of each test specimen, the ratio of the wear volume or the protruded volume to the worn area ($D_e$ or $D_p$) is investigated and proposed as the evaluation parameters of the wear resistance.

A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns (교모면적과 교합접촉양태 간의 관계에 대한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

Relationship between Spring Shapes and the Ratio of wear Volume to the Worn Area in Nuclear Fuel Fretting

  • Lee, Young-Ho;Kim, Hyung-Kyu;Jung, Youn-Ho
    • KSTLE International Journal
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Sliding and impact/sliding wear test in room temperature air and water were performed to evaluate the effect of spring shapes on the wear mechanism of a fuel rod. The main focus was to quantitatively compare the wear behavior of a fuel rod with different support springs (i.e. two concaves, a convex and a flat shape) using a ratio of wear volume to worn area (De)-The results indicated that the wear volumes at each spring condition were varied with the change of test environment and loading type. However, the relationship between the wear volume and worn area was determined by only spring shape even though the wear tests were carried out at different test conditions. From the above results, the optimized spring shape which has more wear-resistant could be determined using the analysis results of the relation between the variation of De and worn surface observations in each test condition.

Effect of Different Golf Shoe treads on Wear and Ball Speed of Putting Green (퍼팅그린의 마모와 골프공의 구름에 미치는 골프화의 영향)

  • 심포룡;심규열
    • Asian Journal of Turfgrass Science
    • /
    • v.11 no.3
    • /
    • pp.205-210
    • /
    • 1997
  • The metal spikes evaluated in this study significantly affected more negative on the turf wear and ball speed of putting green than alternative plastic spikes. 1.The metal spikes caused the most amount of wear compared with plastic spikes, athletic shoes and mountain-climbing shoes. On the other hand, athletic shoes caused the least amount of wear. Plastic spikes caused wear more than athletic shoes, hut apparently wear less than metal spikes. The wear from metal spike repaired later than any other tread types. 2.The wear from all kinds of shoe treads in wetcondition green were higher than in dry-condition green and the wear from metal spikes was more severe compared with plastic spikes in both green condition. 3. Ball speed of heavy compaction area by metal spike was reduced about 9% compared with that of light compaction area, hecause metal spikes made many holes in the putting green surface. On the other hand, plastic spikes did not affect hall speed of heavy and light compaction area in the putting green. Key words: Metal spike, Plastic spike, Wear, Ball speed.

  • PDF

A Study on the Evaluation Parameter of Sliding/Impact Wear in a High Temperature and Pressure Water Condition (고온고압 미끄럼/충격조건에서 마멸평가 변수 연구)

  • Lee Young-Ho;Song Ju-Sun;Kim Hyung-Kyu;Jung Youn-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.37-40
    • /
    • 2004
  • The impact/sliding wear tests have been performed in high temperature high pressure water in order to evaluate the effect of spring shape on the wear behavior of a spring supported tube for nuclear fuel fretting study. The results indicate that the tube wear volume and the size of the wear scar are closely related to each spring shape. From the analysis of the wear scar, it is possible to extract the real worn area (Aw) from the size of the wear scar (At). In addition, we found that the wear volume has a linear relation with the real worm area rather than the size of wear scar and this was only determined by each spring shape in the high temperature and pressure water condition. From the above results, it is possible to evaluate the wear resistant spring using the correlation between the variation of the real worn area and the wear behavior at each spring.

  • PDF

Analysis of Worn Area Characteristic in the Fretting Wear of Nuclear Fuel Rod (핵연료 피복관 프레팅 마멸에서 나타난 마멸면 특성 분석)

  • Lee, Young-Ho;Kim, Hyung-Kyu;Jung, Youn-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.256-261
    • /
    • 2004
  • To evaluate the effect of spring shape on the fretting wear of nuclear fuel rod, sliding wear tests were performed using three kinds of space grid springs in room temperature air and water. With increasing slip amplitude, wear volume of each spring gradually increased. It is apparently shown that spring with convex shape had a relatively high wear resistance compared with concave shape springs. It is suggested that the ratio of the wear volume to the worn area can be suggested as an efficient and valid parameter to evaluate the wear resistibility of a fuel grid spring.

  • PDF

Effects of Combination of the Load and the Apparent Area of Contact on Sliding Wear behavior of Mild Steel in a Pin-on-disc Type Apparatus (Pin-on-Disc식 미끄럼마모시험 시 마모 거동에 미치는 접촉면적 및 하중 조합의 영향)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.29 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • The effects of contact pressure on the sliding wear behavior of mild steel in a pin-on-disc type apparatus were investigated. Sliding wear tests were conducted with various combinations of the load and apparent area of contact. The wear behavior of mild steel as a function of sliding speed was independent of contact pressure. However, the wear rate at different sliding speeds was influenced by the load regardless of the apparent area of contact. This was attributed to the fact that there may be no difference in the real area of contact for any combination of the load and apparent area of contact.

Fracture Mechanics Study on Wear Mechanism of Ceramics -Discussions on Experimental Results of Wear Test- (세라믹의 마멸기구에 관한 파괴역학적 연구 -마멸실험 결과의 고찰-)

  • 김석삼;김재호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.636-645
    • /
    • 1990
  • Analytically induced wear mechanism of elastic body under Hertzian contact is applied in acutual wear test of ceramics. There are two types of wear in ceramics, a large scale wear and a small scale wear. The large scale wear is commensurable with Hertzian contact area and the small scale wear with real contact area. Nondimensional parameter, S$_{c}$, is introduced and fully examined to estimate or predict wear rate of ceramics. Ceramic wear for S$_{c}$.leq.0.8 is in small scale wear and for S$_{c}$;geq.1.6 in large scale wear. wear.

A STUDY ON THE FACTORS AFFECTING TO TOOTH WEAR (치아교모에 영향을 미치는 요인에 관한 연구)

  • Park, Hyun-Bae;Han, Kyung-Soo;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.328-342
    • /
    • 1999
  • This study was performed to investigate the factors related to tooth wear. For this study, 78 patients with temporomandibular disorders and 76 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the normal group, respectively. Preferred chewing side, Angle's classification, lateral guidance pattern, head and shoulder posture were observed clinically. Electromyographic activity of anterior temporalis and masseter muscle were recorded with $BioEMG^{(R)}$ and occlusal status were recorded with $T-Scan^{(R)}$. Wear facet area of each tooth was measured from working model of upper arch corresponding to the occlusal status from T-Scan. Wear facet area were measured with planimeter in $mm^2$. Total area were divided into incisal, canine, posterior tooth area. Anterior wearfacet area was incisor area plus canine area, and unilateral area was anterior area plus posterior area. The data collected were analyzed by SAS statistical program and the results of this study were as follows: 1. There was no significant difference between the two groups in total werafacet area, and male subjects showed tendency to have larger area in the normal group but female subjects showed tendency vice versa. 2. There was no significant difference related to preferred chewing side and Angle's classification, however some difference was observed by lateral guidance pattern. Anterior wear facet area in subjects of canine guidance was the largest in the three subgroups. 3. Subjects with head tilting to right side had larger posterior and total area, and subjects with higher shoulder in right side had larger canine and anterior area than any other subgrous. 4. Electromyographic activity of masseter muscle was more correlated with wear facet area than anterior temporalis muscle, and tooth contact number and force were significantly correlated with wear facet area, but the most important factor affecting tooth attrition was age.

  • PDF

Effect of Contact Area on Friction and Wear Behavior in Atomic Force Microscope (원자 현미경을 이용한 접촉 면적에 따른 마찰 및 마멸 특성 분석)

  • Choi Dukhyun;Hwang Woonbong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.167-173
    • /
    • 2004
  • Recently, it has been reported that frictional behavior at nanometer scale can be different from that at macro scale. In this article, friction and wear tests were conducted using an AFM to investigate the effect of real contact area on the coefficient of friction and wear property. SiO$_2$, Hica, and SiGe were used in friction test and the AFM tip was Si$_3$N$_4$. The real contact area between an AFM tip and flat surface was calculated by the Johnson-Kendall-Roberts (JKR) theory. Wear specimen was Mica, and the diamond tip was used. We found that the coefficient of friction is constant below a critical area, but it is degraded over the area. Moreover, it is found that wear depth increased rapidly from a certain load and was degraded as a function of the number of the scanning cycles. Also, the range of scanning velocity used in this study had little effect on the wear depth.