• Title/Summary/Keyword: Wavelength Swept Laser

Search Result 40, Processing Time 0.022 seconds

Frequency Swept Laser at 1300 nm Using a Wavelength Scanning Filter Based on a Rotating Slit Disk

  • Jeon, Man-Sik;Jung, Un-Sang;Song, Jae-Won;Kim, Jee-Hyun;Oh, Jung-Hwan;Eom, Jin-Seob;Kim, Chang-Seok;Park, Young-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.330-334
    • /
    • 2009
  • A simple and compact frequency swept laser is demonstrated at $1.3{\mu}m$ using a wavelength scanning filter based on a rotating slit disk. The laser is comprised of a pigtailed semiconductor optical amplifier, a circulator, and a wavelength scanning filter in an extended cavity configuration. The wavelength scanning filter is composed of a collimator, a diffraction grating, a rotating slit disk, and a mirror. The instantaneous laser output power is more than 5 mW. The scanning range of the laser is extended to 80 nm at the maximum level, and 55 nm in the full width at half maximum at a scanning rate of 2 kHz.

Sweeping Automatic Linearization for Wavelength Swept Laser Used in Structure Safety Monitoring (구조물 안전 모니터링용 파장 스위핑 레이저를 위한 스위핑 자동 선형화)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • In this study, a novel method for sweeping automatic linearization of wavelength swept laser is proposed. Through the test performed on the implemented laser, the linear sweeping is held up well with a 97% decrease in nonlinearity, and 60 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The proposed method uses fiber Bragg grating array, optical-electronic conversion circuit, FPGA embedded module, and a LabVIEW program to generate new compensated wave patterns which were applied to the fiber Fabry-Perot tunable filter. Linear sweeping can reduce the cumbersome and time-consuming recalibration process required for nonlinear sweeping. Additionally, the proposed method provides more accurate measurement results for the structure safety monitoring system.

Sweeping Linearization of Wavelength Swept Laser using PID Control (PID 제어를 이용한 파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a PID control method for sweeping automatic linearization of a wavelength swept laser is proposed. First, the closedloop transfer function embodying the PID control is derived. Through the simulation of the function, Kp = 0.022, Ki = 0.008, Kd = 0.002 were obtained as the best PID coefficients for fast linear sweeping. The performance test using the PID coefficients showed that linear sweeping was held up well with a 98.7% decrement in nonlinearity after the 10th feedback, and 45 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The equipment consists of a fiber Bragg grating array, an optical-electronic conversion circuit, and a LabVIEW FPGA program. Every 5s, automatic feedback and PID control generate a new compensated waveform and produce a better linear sweeping than before. Compared with nonlinear sweeping, linear sweeping can reduce the cumbersome and time-consuming recalibration processes and produce more accurate measurement results.

Flat Sweeping Automatic Hold of Wavelength Swept Laser (파장 스위핑 레이저의 평탄 스위핑 자동 유지)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.606-613
    • /
    • 2019
  • In this paper, a new method for flat sweeping automatic hold of wavelength swept laser has proposed. Through the performance test on the implemented laser, even 5 hours passed, the flat sweeping has held up well, and 56nm flat sweeping range, 1kHz sweeping frequency, and 8.8mW average optical power were obtained. This showes that the proposed can eliminate the necessity of hand-operated polarization control required for previous swept lasers in case of long time operation and also optical spectrum analyzer needed to monitor the sweeping spectrum status.

Automatic Sweep Flattening for Wavelength Sweeping Laser of SS-OCT (SS-OCT용 파장 스위핑 레이저를 위한 자동 스위프 평탄화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • In this paper, the automatic sweep flattening for wavelength swept laser of SS-OCT has implemented. Through its performance test applied to the laser, 50 nm flat sweeping range, ${\pm}0.5dB$ fluctuation range, 22 sec the time required, and 10 mW average optical power were obtained. This shows that the realized automatic process can replace the inconvenient manual operation used for polarization control of current sweeping laser. Additionally it cuts costs for optical spectrum analyzer necessary to sweep monitoring.

Realization of Swept Source-Optical Coherence Tomography using FDML Laser (FDML 방식 스위핑 광원을 사용한 SS-OCT 구현)

  • Eom, Jin-Seob
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • In this paper, the swept source-optical coherence tomography system using frequency domain mode locked(FDML) laser has realized. The FDML swept source laser showed 55.03 kHz sweeping speed, 125 nm sweeping range, and 9 mW output optical power, which are the superiority of FDML laser compared to previous swept source lasers. Also, through the cross-sectional image captured at 5 frames per second for a mirror, a 1 mm-thickness glass plate, and a thumb bottom, the performance of the system has demonstrated.

Measurement of Hysteresis in PZT-Type Tunable Filters Utilizing OFDR (OFDR을 이용한 PZT형 파장가변 필터의 이력 측정)

  • Park, Do-Hyun;Yeh, Yun-Hae
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2008
  • Implementation of a wavelength-swept source with constant tuning rate adopting a PZT-type tunable filter, requires the knowledge of hysteresis of the filter used. The hysteresis must be considered to avoid any degradation in resolution of the optical frequency domain reflectometry (OFDR) system. An optical spectrum analyzer (OSA) could be used to do the hysteresis measurement, but its measurement time is too long for the high-speed driving conditions for the filter. We proposed a new hysteresis measurement method based on OFDR, which could measure the hysteresis in a real driving condition. A hysteresis measurement apparatus consisted of wavelength-swept source, interferometer, signal processing unit, and PC program is built and used to do the measurement. It is concluded that the new method is useful in the measurement of hysteresis at real driving conditions by successfully implementing a swept-wavelength source whose wavelength change is linear in time.

Characteristics of a Wavelength-swept Laser with a Polygon-based Wavelength Scanning Filter (다면체 거울 스캐닝 파장 필터를 이용한 파장 훑음 레이저의 출력 특성)

  • Ko, Myeong Ock;Kim, Namje;Han, Sang-Pil;Park, Kyung Hyun;Lee, Bong Wan;Jeon, Min Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.61-66
    • /
    • 2014
  • We report the characterization of a wavelength-swept laser (WSL) using a polygon-based wavelength scanning filter and two semiconductor optical amplifiers (SOAs). The output intensity and scanning bandwidth of the WSL depend on the position of the two SOAs in the laser cavity and the coupling ratio of the output fiber coupler. The outputs of the WSL are characterized for coupling ratios of 10%, 30%, 50%, 70%, and 90% for the output fiber coupler. In the setup in which the output fiber coupler is located between the two SOAs, high output power and wide scanning bandwidth can be achieved with an optimized configuration. Using the optimized configuration of the WSL, the intensity increases with the coupling ratio. These results can be used to construct an optimized WSL using the polygon-based wavelength scanning filter.

Acquirement of in vivo epidermal cross-sectional image by using swept source optical coherence tomography (SS-OCT 방식을 이용한 생체의 표피단면 영상 획득)

  • Kim, Hoon-Sup;Lim, Hae-Jin;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.163-166
    • /
    • 2008
  • In this paper, the swept source optical coherence tomography system has realized using a free-space interferometer based on a beam splitter. Personal computer has completed the control for tunable wavelength laser digitally and the B-scan motor as well. From each experiment for an onion and a salmon egg, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

Implementation of the Wavelength-Swept-Source and Signal Processing for the Frequency Domain Optical Coherence Tomography (주파수영역 광 간섭 단층촬영 시스템을 위한 파장가변 광원 및 신호처리계의 구현)

  • Lee, Eung-Je;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.309-316
    • /
    • 2007
  • We demonstrate the wavelength swept source and signal processing for the frequency domain optical coherence tomography. The laser output performance is improved by using a semiconductor optical amplifier with a booster amplifier. The laser generates 14 mW of average power of which wavelength shift in the lasing spectral shape is compensated. Adopting a Fabry-Perot etalon and digital signal processing, the broadening of the beat frequency due to the variance of wavelength-sweep-velocity is calibrated. The optical coherence tomography system shows 154.4 kHz of axial scanning speed, 0.95mm of depth range, and $12{\pm}0.37{\mu}m$ of axial resolution.