• Title/Summary/Keyword: Waveguide analysis

Search Result 398, Processing Time 0.025 seconds

The Two Dimensional Analysis of RF Passive Device using Stochastic Finite Element Method (확률유한요소법을 이용한 초고주파 수동소자의 2차원 해석)

  • Kim, Jun-Yeon;Jeong, Cheol-Yong;Lee, Seon-Yeong;Cheon, Chang-Ryeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.4
    • /
    • pp.249-257
    • /
    • 2000
  • In this paper, we propose the use of stochastic finite element method, that is popularly employed in mechanical structure analysis, for more practical designing purpose of RF device. The proposed method is formulated based on the vector finite element method cooperated by pertubation analysis. The method utilizes sensitivity analysis algorithm with covariance matrix of the random variables that represent for uncertain physical quantities such as length or various electrical constants to compute the probabilities of the measure of performance of the structure. For this computation one need to know the variance and covariance of the random variables that might be determined by practical experiences. The presenting algorithm has been verified by analyzing several device with different be determined by practical experiences. The presenting algorithm has been verified by analysis several device with different measure of performanes. For the convenience of formulation, two dimensional analysis has been performed to apply it into waveguide with dielectric slab. In the problem the dielectric constant of the dielectric slab is considered as random variable. Another example is matched waveguide and cavity problem. In the problem, the dimension of them are assumed to be as random variables and the expectations and variances of quality factor have been computed.

  • PDF

Analysis of Coplaner $LiNBO_3$ Waveguide Structures Applicable Electrooptic Modulator with FDTD method

  • Lee, Byung-Je;Byun, Joon-Ho;Kim, Nam-Young;Kim, Jong-Heon;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1211-1217
    • /
    • 2000
  • The three-dimensional finite-difference time-domain (FDTD) method and the two-dimensional quasi-static formulation have been used to calculate the characteristic impedance and the microwave effective index of coplanar waveguide structures on Lithium Niobate ($LiNBO_3$) single crystal substrates with a yttria-stabilized zirconia (YSZ) or $SiO_2$ buffer layer. The results shown can be a good source to predict the modulator characteristics. The effects of the thin buffer layer and anisotropy of the $LiNBO_3$ crystal (x-cut and z-cut) are discussed. The comparison between the FDTD and quasi-static results shows good agreement. In this paper, the efficient modeling technique of the FDTD method for the coplanar waveguide (CPW) structures based on an anisotropic substrate with a thin buffer layer is developed.

  • PDF

Analysis of Coupled Mode Theory for Design of Coupler Between Optical Fiber And Grating Assisted Waveguide (광섬유와 격자구조 도파로 결합기 설계를 위한 결합 모드 이론 분석)

  • Heo, Hyung-Jun;Kim, Sang-In
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.561-568
    • /
    • 2017
  • In order to effectively utilize the Coarse Wavelength Division Multiplexing(CWDM) technology in optical integrated devices, a design of a wavelength selective coupler structure between an optical fiber and an optical waveguide in a flat substrate is can be considered. In this paper, we consider the coupling between a silicon waveguide with an air trench and a single mode fiber. We investigated the tendency of coupling efficiency and its limitations according to the grating depth. For this purpose, the coupling efficiency of coupler structure designed through modeling based on coupled mode theory is predicted and quantitatively compared with simulation results using finite element method.

Transmission Characteristics on Swelling Tolerances of Rectangular Waveguides for Q-Band (Q-Band용 도파관의 내부 돌기가 전송 특성에 미치는 영향)

  • Park, Kyung-Sik;Cho, Byung-Ho;Kim, Ki-Chai;Kang, Jin-Seob;Kim, Jeong-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.108-113
    • /
    • 2014
  • This paper presents the influence on the transmission characteristics of swelling in rectangular waveguides for Q-band. We derived the Green's functions of the waveguide with eigenfunction expansion method. The reflection coefficient of the waveguide with a swelling is calculated by using internal impedance in order to investigate the influence of swelling in the waveguide. In order to check the validity of the theoretical analysis, the calculated reflection coefficients are compared with the measured results.

Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor (펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구)

  • Choi, Woo-Jin;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

Transmission Characteristics on Dimensional Tolerances of Millimeter-Wave Rectangular Waveguides (밀리미터파용 구형 도파관의 단면 치수 변화에 의한 전송 특성)

  • Park, Kyung-Sik;Kim, Ki-Chai;Kang, Jin-Seob;Kim, Jeong-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.722-729
    • /
    • 2013
  • This paper presents the influence on the transmission characteristics of dimensional tolerances of rectangular waveguides usually used as a low-loss transmission line in the millimeter-wave band. We derived the Green's functions of the waveguide with eigenfunction expansion method. The reflection coefficient of the waveguide with a post is calculated by using internal impedance in order to investigate the influence of dimensional tolerances of the waveguide. In order to check the validity of the theoretical analysis, the calculated reflection coefficients are compared with the measured results.

Design of Broadband Corrugated Waveguide Polarizer (광대역 커러게이트 도파관 편파기 설계)

  • 양두영;이민수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.89-96
    • /
    • 2000
  • In this paper, the design theory of the corrugated polarizer using square waveguide is proposed. In order to analysis the characteristic of square waveguide discontinuity as well as achievement of the low VSWR, we apply the modified $TE^\chi_mn$ mode matching method and the corrugated exponential function to the polarizer design. The results show a broadband characteristic that phase shift angle is nearly appeared $90^{\circ}$ in the range of 11.7-15.8GHz. Especially, we could be designed the Ku-band dual polarizer for the satellite broadcasting transponder with 300MHz bandwidth. Its phase shift angle and maximum VSWR, axial ratio are $90^{\circ},\pm1^{\circ}$, 1.03, and 1.0001 in the range of 11.7-12.0GHz and 14.5-14.8GHz, respectively.

  • PDF

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

Implementation of Bio-Sensor with Coupled Plasmon-Waveguide Resonance Profile (결합된 플라즈몬-도파관 공진 구조로 구성된 바이오센서의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.109-114
    • /
    • 2024
  • The bio-sensing properties of TE and TM guided modes in the coupled plasmon-waveguide resonance (PWR) configuration are investigated. The modal transmission-line theory (MTLT) is used for numerical analysis. The proposed PWR bio-sensor is composed of multi-layered configuration with N pairs of MgF2-Si3N4 layers to enhance the sensitivity of a conventional Ag-based surface plasmon resonance bio-sensor. The angular sensitivity of bio-sensor is numerically analyzed for a wide range of biological solutions (refractive index 1.33~1.37). Furthermore, the availability of sensor to detect cancer cells and blood plasma concentration is evaluated. Finally, the results indicate that the proposed bio-sensor is capable efficiently to detect various kinds of cancer cells and different glucose concentrations in urine.