• Title/Summary/Keyword: Waveguide Measurement

Search Result 207, Processing Time 0.022 seconds

Oscillator Strength of Normal-incidence Intersubband Absorption in Conduction Bands of Si and Ge Quantum Wells Using Polarization

  • Lee, Chanho
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.80-85
    • /
    • 1998
  • A theoretical calculation and an optical measurement method of normal-incidence absorption are proposed. By using a waveguide structure, optical interference and the problem of low level signal can be avoided in the measurement of normal-incidence absorption. The oscillator strength of intersubband absorption for a waveguide structure is calculated in Si(001), Si(110), and Ge(001) quantum wells. The polarization angle dependence of the measured and the calculated absorption strength can be obtained with the same waveguide structure, and be compared after normalization. The normal-incidence absorption in Si(110) and Ge(001) quantum wells is shown theoretically, and can be observed in the optical measurement using waveguide structures at the polarization angle of 90$^{\circ}$.

  • PDF

Microwave Rectangular Waveguide Measurement of the Engine Oil Dielectric Constant (초고주파 구형도파로를 이용한 엔진 오일의 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • The rectangular waveguide technique can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents the analysis system of engine oil permittivity at which deterioration of engine oil is measured at the X-band(8-12.5 GHz). The middle of the rectangular waveguide has engine oil case and is connected with VNA(Vector Network Analyzer) for the measurement of the transmission$(S_{21})$ and reflection$(S_11)$ and then the permittivity is extracted. The deterioration of engine oil is proved by the comparison with both the extracted data and reference data. As the additional research, This paper suggest that an accurate permittivity is considered by not only the wave guide length but the air gap between oil case and the waveguide.

Low Coherence Interferometer for Measurement of Path Length Errors in Arrayed-Waveguide Grating (Arrayed-Waveguide Grating의 경로 오차 측정을 위한 저 간섭 광원 간섭계)

  • Song, Young-Ki;Heo, Nam-Chun;Chung, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.539-546
    • /
    • 2004
  • An improved low coherence interferometer system and a new analysis method for the accurate measurement of the optical path difference error of an AWG (Arrayed-Waveguide Grating) are described. The use of software simplifies the experimental setup by eliminating the hardware (clock generator). In addition, the actual distances between the peak positions of the adjacent interference signals are calculated using interpolation methods. The wavelength transmission characteristics of the AWG are calculated assuming the measured phase errors. The calculated AWG characteristic is quite similar to the actual measurement result, confirming accuracy of the proposed measurement setup.

Optical-Loss Measurement of a Silicon-Slab Waveguide

  • Tresna, Wildan Panji;Putra, Alexander William Setiawan;Maruyama, Takeo
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.551-557
    • /
    • 2020
  • A mirror-in-slab waveguide is fabricated on a slab waveguide by using the refractive-index contrast between two materials, with the reflection performance depending on the slab waveguide's design. In this research, a slab waveguide design consisting of silicon (Si) as the core and SiO2 as the substrate was designed and developed to determine the coupling, waveguide, and mirror losses. Based on experimental results, coupling loss is dominant and is affected by the design of the slab waveguide. Furthermore, the mirror loss is affected by the design of the mirror, such as the curvature radius and the size of the mirror. TE and TM polarizations of light are used in the measurements. The experimental results show that mirror losses due to reflection by mirrors are 0.011 dB/mirror and 0.007 dB/mirror for TE and TM polarizations respectively. A simulation was performed to confirm whether the size of mirror is sufficient to reflect the input light, and to check the quality of the surfaces of fabricated mirrors.

A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide (평행판 도파관을 이용한 유전율 측정 방법)

  • Cho, Gyo-Yeong;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.199-203
    • /
    • 2012
  • This paper introduces a simple new procedure approach to determine the permittivity of dielectric slabs. The method uses a parallel plate waveguide which supports a TEM mode. The presence of the dielectric slab placed at the bottom of the waveguide makes the speed of the TEM wave slower. The relationship between the change of the speed and the permittivity of the dielectric slab allows the determination of the permittivity. The relationship is analyzed electromagnetically, and the results of measurements are in good agreement with the analysis.

Analysis and Measurement of Effective Refractive Indices with Ion-exchanged Slab Waveguide (이온교환 평판도파로의 실효굴절율 측정 및 해석)

  • 천석표;박정일;박태성;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.73-76
    • /
    • 1995
  • In this study, the slab waveguide was fabricated using potassium-nitride(KNO$_3$) or silver-nitride (AgNO$_3$) molten sources by ion-exchange process. The effective refractive indices of waveguide were measured by Prism-Coupling method. and The characteristics of waveguide(mode dispersion, effective diffusion depth. surface refractive index, diffusion coefficient, and refractive index profile etc,) were investigated by WKB method, In the case of potassium ion-exchange, the computer calculation showed that the refractive index profile of waveguide followed Gaussian function, the surface refractive index increased with ion-exchange time and the effective diffusion depth increased a little as ion-exchange time increased, while the surface refractive index of silver ion-exchanged waveguide decreased with ion-exchange time because of the ion depletion on the surface of waveguide, and the effective diffusion depth seriously with ion-exchange tim. Double ion-exchanged waveguide was fabricated by performing silver ion-exchange after potassium ion-exchange. Double ion-exchanged waveguide had a tight mode binding force since the surface refractive index was larger than single step ion-exchanged waveguide.

  • PDF

Non-Resonant Waveguide Technique for Measurement of Microwave Complex Permittivity of Ferroelectrics and Related Materials

  • Jeong, Moongi;Kim, Beomjin;Poplavko, Yuriy;Kazmirenko Victor;Prokopenko Yuriy;Baik, Sunggi
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.7 s.278
    • /
    • pp.449-454
    • /
    • 2005
  • A waveguide method is developed to study the materials with relatively large dielectric constants at microwave range. Basically, the method is similar to the previous waveguide methods represented by short-circuit line and transmission/reflection measurement methods. However, the complex permittivity is not determined by the shift in resonance frequencies, but by numerical analysis of measured scattering parameters. In order to enhance microwave penetration into the specimen with relatively large permittivity, a dielectric plate with lower permittivity is employed for impedance matching. The influences of air gap between the specimen and waveguide wall are evaluated, and the corresponding errors are estimated. The propagation of higher order modes is also considered. Experimental results for several reference ceramics are presented.

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.

FM Reflectometric Measurement of Group Velocities of Microwave Transmission Lines

  • Park, Yong-Hyun;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.67-71
    • /
    • 2003
  • In this paper, frequency modulated(FM) reflectometry is proposed to measure group velocity of microwave transmission line Various microwave transmission lines such as periodically loaded conducting posts in a waveguide and nonradiative dielectric(NRD) guide are adopted to measure their group velocity The result compared with that from network analyzer shows good agreement, indicating the validity of our measurement method.

Development of an Optical Waveguide Loss Measuring System using an Rectangular Glass Probe

  • Choi, Young-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.71-79
    • /
    • 2001
  • The use of a glass-plate probe of rectangular shape is proposed for the measurement of transmission loss in optical waveguides. The light-collecting window is of a thin, rectangular shape and is perpendicular to the light streak, while the conventional fiberglass probe has a small circular face. This transversely elongated form results in a grate improvement of mechanical tolerance for the probe movement in the vortical as well as in the transverse direction. A theoretical investigation also presents a reasonable agreement with the experiments.

  • PDF