• Title/Summary/Keyword: Water-vapour resistance

Search Result 9, Processing Time 0.027 seconds

A Study on the Textile for Protective Clothing of Fire Fighters (한국 소방대원 방수피복의 소재특성에 관한 비교 연구)

  • 정정숙;이연순
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.5
    • /
    • pp.15-24
    • /
    • 2002
  • The following research conclusions were made, relative to the experiments of the textiles of fire fighters Protective Clothing. 1. When the body protection efficiency such as the thickness, the strength and heat resistance are considered, Nomex(N) is tuned out the best outer shelf, Gore-tex(KG) the best moisture barrier, and Wool-felt(WC) the best thermal barrier. 2. In the hygienic and sanitary efficiency also, N is turned out the best outer shelf, KG the best moisture barrier, and WC the best thermal barrier in its degree of water resistance, water vapour permeability, and air permeability. 3. In the washing and maintenance efficiency, too. N is turned out the best outer shell, KG the best moisture barrier, and WC the best thermal barrier, being considered the material's rate of contraction, the changing rate of frame resistance, water resistance, and water vapour permeability. 4. When considered the frame resistance against the reflection tape and reflection efficiency, O is the best material for it marks the highest score in the frame resistance and reflective effect.

Water Vapour Permeable/Water Resistant and Heat Resistant Finishing of Footwear Fabric (신발용 직물의 투습방수 및 내열성 가공)

  • Lee, Jae Ho;Choi, Hae Wook
    • Journal of Adhesion and Interface
    • /
    • v.7 no.3
    • /
    • pp.16-25
    • /
    • 2006
  • Water vapour permeable and water resistant film was laminated to made footwear woven fabric and non-woven fabrics by screen type with thermosetting reactive hot melt adhesive. Optimum conditions of each process were investigated, and the properties of film laminated fabric with optimum conditions are evaluated. The results are as follows. Thermosetting reactive polyurethane hot melt is retain proper heat resistance differently thermoplastic hot melt. Optimum melting adhesive process conditions are as follows ; drum temperature $95^{\circ}C$, hose temperature $97^{\circ}C$, feeding pipe temperature $100^{\circ}C$, screen temperature $105^{\circ}C$, pressure of opposite roller $1kgf/cm^2$, pressure of laminating roller $3kgf/cm^2$, finishing speed 15 m/min, melting temperature $120^{\circ}C$, cooling time 20 s, pressing temperature $130^{\circ}C$, pressing time 30 s. As the thickness of film was increased, the water vapour permeability was decreased but water resistance was increased, and the effect of film is dominant over all the others in the air permeability.

  • PDF

The Textiles and the Performance Level in Developing the Pesticide Proof Clothing (기능성 농약방제복 개발을 위한 소재 및 성능에 관한 연구)

  • Hwang, Kyoung-Sook;Kim, Kyung-Ran;Lee, Kyung-Suk;Kim, Hyo-Cher;Kim, Kyung-Su;Baek, Yoon-Jeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1611-1620
    • /
    • 2007
  • The precaution to spray with agricultural chemicals is very important, in particular personal protective equipment against pesticide in order to protect farmers# pesticide poisoning. The Ministry of Agriculture and Forestry has proclaimed the announcement of pesticide proof clothing(PPC) in 1983, and revised it in 1987. The announcement had many performance items to achieve the high-quality protective clothing for pesticide including weight, density, force strength, dimensional change(in washing and drying), fastness(dyeing, washing, sweating and rubbing) and water resistance of clothes. Announcement of the PPC has better durability and penetration resistance function than former days, but the plenty of farmers didn#t wear it because of the intolerable heat. To increase wearing rates, the pesticide proof clothing must be estimated the water-vapour resistance. From the results, the developed PPC with polyester treated water-repellent showed the more excellent comfort than an existing PPC with nylon coated polyurethane. But the developed PPC appeared to have the low water-vapour resistance. Therefore, it is suggested that the property of pesticide penetration must be evaluated through the field test in the future study.

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF

Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board (가속수명시험을 이용한 은도통홀 인쇄회로기판의 신뢰성연구)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.2
    • /
    • pp.15-27
    • /
    • 1997
  • This paper describes a highly accelerated life test (HALT, USPCBT) method for rapid qualification testing of STH PWB(Silver Through Hole Printed Wiring Boards). This method was carried out to be an alternative to the present time-consuming standard 1344 hours life testing(THB). The accelerated life test conditions were $121^{\circ}C$/95%R.H. at 50V bias and without bias. Their results are compared with those observed in the standard 1344 hours life test at $40^{\circ}C$/95%R.H. at 50V bias and without bias. The studies were focused on the samples time-to-failure as well as the associated conduction and failure mechanisms. The abrupt drop of insulation resistance is due to the absorption of water vapour. And the continuous drop of insulation resistance is due to the Ag migration. The ratios of time-to-failure of HALT(USPCBT) to THB were 25 and 11 at 50V bias and without bias respectively.

  • PDF

A Study on Standardization of Test Method for Water Vapour Permeability of Textiles Fabrics (군용 피복류의 투습도 시험방법 표준화 연구)

  • Lee, Min-Hee;Hong, Seong-Don;Chung, Il-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.27-33
    • /
    • 2016
  • Military textiles with breathable waterproof materials are expanding as form of winter clothes. Waterproof moisture-permeable clothes are very important for soldiers to survive in cold weather operations because they prevent loss of body heat from the penetration of water into the human body. Korea military uses the water resistance and moisture permeability to test the performance of waterproof moisture-permeable materials. Moisture permeability is measured according to the amount of evaporated water vapor passing through a fabric under specified temperature and humidity by using acetic acid potassium presented in KS K 0594. However, the test procedure for measuring the moisture permeability in the standard is presented only briefly and the preparation procedures for the test in accredited testing institutions are applied differently, leading to significant deviation of the results. This paper compares the procedures of testing institutions and examines the factors that affect moisture permeability. Finally, we propose a procedure to reduce the deviation of results and apply the proposed procedure in testing institutions. Our analysis results with one-way ANOVA under significant level (0.05) confirm that the deviation of results is reduced.

Change of the Protection Efficiency in Each Part of Developed Pesticide-Proof Clothes by Repeated Washings (개발 과수용 농약방제복의 반복세탁에 따른 부위별 농약 방호성능의 변화)

  • Shin, Jeoung-Hwa;Hwang, Kyoung-Sook;Lee, Hyo-Hyeon
    • The Korean Journal of Community Living Science
    • /
    • v.22 no.4
    • /
    • pp.615-621
    • /
    • 2011
  • This study was conducted to evaluate of the protection efficiency in each part of developed pesticide-proof clothes by repeated washings. We investigated the effect of repeated laundering on mechanical properties of pesticide-proof clothes (not washed vs 5 times washed). We also examined pesticide infiltration rate into the pesticide-proof clothes by repeated laundering. The patches(TCL paper, surface area 50cm2)were attached to the inside of pesticide-proof clothes(head, chest, right upper-arm, right forearm, left thigh, left calf, back) which subjects had dressed in during pesticide spraying. The patches were detached from working clothes after work. For the extraction of pesticide in pesticide-proof clothes, sonication was applied for 30 min with methanol. The gas chromatography/mass spectrometry (GC/MS) was applied to identify the pesticide component. The results of this study are as follows: The force strength, water-vapour resistance and surface wetting resistance of pesticide-proof clothes decreased 5 times more in washed clothes. The concentration of pesticide was the highest in the head area of pesticide-proof clothes. In seven parts of TLC paper attached to the pesticide proof clothes, the concentration of pesticide was higher in the left thigh. The penetration part and concentration of pesticide increased as washing was repeated. Therefore the conclusion which can be drawn from this study is this: protection efficiency of pesticide-proof clothes decrease by repeated washings.

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

Study on the High Temperature Properties of Fireproof Mortar Using Various Types of Fine Aggregate (잔골재 종류에 따른 내화피복용 모르타르의 고온 성상에 관한 연구)

  • Lim, Seo-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.100-106
    • /
    • 2014
  • High strength concrete has a structural advantage as well as superior usability and durability, so that its application in building is being steadily augmented. However, in the high temperature like in a fire, the high strength concrete has extreme danger named explosive spalling. It is known that the major cause of explosive spalling is water vapour pressure inside concrete. General solution for preventing concrete from spalling include applying fire protection coats to concrete in order to control the rising temperature of members in case of fire. The purpose of this study is to investigate the high temperature properties of fireproof mortar using organic fiber and various types of fine aggregate for fire protection covering material. The results showed that addition of perlite and polypropylene fiber to mortar modifies its pore structure and reduces its density. This causes the internal temperature to rise. As a results, it is found that a new fireproof mortar can be used in the fire protection covering material in high strength concrete.