• 제목/요약/키워드: Water-tank experiment

검색결과 398건 처리시간 0.029초

중거리에서 대류경계층 연직방향 plume 확산의 일반화 (Generalization of Vertical Plume Despersion in the concective Boundary Layer at Long Distances on Mesoscale)

  • 서석진
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.141-150
    • /
    • 2000
  • In order to genralize the vertical dispersion of plume at long distances on mesoscale over complex terrain dispersion coefficients data have been obtained systematically according to lapsed time after release by using a composite turbulence water tank that simulates convective boundary layer. Dispersion experiments have been carried out for various combined conditions of thermal turbulence intensity mechanical turbulence intensity and plume release height at slightly to moderately unstable conditions. Results of tracer dispersion experiments conducted using water tank camera and image processing system have been converted into atmospheric dispersion data through the application of similarity law. The equation $\sigma$z/Zi=aX/(b+c X2)0.5 where $\sigma$2; vertical dispersion coefficient zi : mixing height X : dimen-sionaless downwind distance was confirmed to be an appropriate and general equation for expressing $\sigma$2 variation with turbulence intensity and plume release height, The value of "a" was found to be principally affected by mechanical turbulence intensity and that of "b" by mechanical turbulence intensity and release height. It was confirmed that the magnitude of "c" varies with release height. Results of water tank experiments on the relationship of $\sigma$2 vs downwind distance x have been compared with actual atmospheric dispersion data such as CONDORS data and Bowne's nomogram Operating conditions of a composite turbulence water tank for simulating the field turbulence situations of CONDORS experiments and Bowne's $\sigma$2(x) nomogram for suburban area have also been investigated in terms of water temperature difference between convection water tank and bottom plate heating tank grid plate stroke mixing water depth length scale and velocity scale. Moreover the effect of mechanical turbulence intensity on vertical dispersion has been discussed in the light of release height and downwind distance. height and downwind distance.

  • PDF

나선유로에 의한 태양열 축열조 성층화 촉진(제1보 실증실험) (Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 1:Verification Experiment))

  • 권재욱;홍희기
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.336-342
    • /
    • 2012
  • Large-scale active solar heat systems are generally using heat exchanger between collector and storage tank loops to prevent damage by freezing. It is difficult to maintain stratification in a storage tank in the system owing to greater flow rate enhancing heat transfer. In the previous study, we introduced a spiral-jacketed storage tank and obtained good results to keep system performance of general level without better stratification. We added a scroll-shaped heat exchanger coil on the upper part in the spiral-jacketed storage tank. As a result of the experiment, it was verified that degree of stratification of the new type storage tank is higher than that of the previous one with a possibility of better collector efficiency and solar fraction.

GPR 탐사방법을 이용한 유류오염물질(LNAPL) 탐지 (LNAPL Detection with GPR)

  • 김창렬
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2001년도 정기총회 및 제3회 특별지포지움
    • /
    • pp.94-103
    • /
    • 2001
  • 유기 석유화학 오염 물질인 휘발유가 지하 분포 시, 지하수면 위 토양 매질(vadose zone)내에 존재할 수 있는 기체 상태(vaporphase)와, 지하수면의 상승 또는 하강에 의해 분포 할 수 있는 residual phase의 유류 오염 물질이 GPR에 미치는 반응을 조사하기 위하여 모래와 자갈을 토양 매질로서 채운 탱크를 이용한 모델 실험이 수행되었다. 물만 사용하여 지하수면의 상승과 하강을 유도한 후, 석유 수송을 위하여 지하에 매장된 파이프 혹은 석유저장을 위한 지하 탱크로부터 지하수면으로의 유류 오염을 simulation하기 위하여 모델 탱크바닥을 통하여 휘발유가 주입되었다. 본 연구 결과, 수분 함량에 따른 GPR의 민감성과 지하수면의 변화 관측에의 GPR 효율성이 입증되었다. 또한, 휘발성 유류 오염 물질의 기체상태가 vadose zone에 분포 시 GPR를 이용하여 탐지할 수 있는 가능성과, 지하수면의 상승에 의해 지하수면 밑의 물로 포화된 토양(water saturated zone)에 분포할 수 있는 residual phase의 유류 오염 물질의 탐지 가능성이 모델 실험을 통하여 확립되었다 그리고, residual phase의 유류 오염 물질이 지하수면 아래에 분포하는 오염지역에서 GPR을 이용한 유류 오염물질을 탐지할 수 있는 새로운 탐사전략이 제시되었다.

  • PDF

고층건물 내진설계용 TLD의 유한요소 해석에 관한 연구 (Study of Finite Element Analysis of Tuned Liquid Damper for Seismic Design of High-Rise Building)

  • 박성우;조진래;이재훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.597-602
    • /
    • 2006
  • Many researches have been studied several vibration control device such as TMD and TLD to reduce the influence of wind or seismic waves for high-rise buildings. TLD provides some advantages such as easy installation and low maintenance cost. However, because of the difficulties in evaluating the characteristics of TLD, the dynamic characteristics of TLD must be investigated by experiment or analysis. In this study, the dynamic response analysis of structure with TLD was carried out to verify the vibration control ability of the proposed TLD for high-rise building with about 60 stories. A real seismic wave was used, and the parameter of interest was chosen by the height of water level in the same shape of water tank. From the numerical results, the responses of structure with water tank were confirmed to be safer than those of structure without water tank.

  • PDF

트롤 모니터링 시스템의 개발에 관한 연구 ( 1 ) - 트롤 전개판의 전개 간격 계측 시스템 - (Development of Trawl Monitoring System ( 1 ) - Distance Measuring System between Trawl Doors -)

  • 신현옥;이춘우
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.189-193
    • /
    • 1997
  • We make an ultrasonic system as a trial to measure the distance between trawl doors, and carried out a water tank ($24{\times} 24$m, water depth 1 m) experiment for confirming the practical use of the system in October 1996. This system calculates the distance between the pinger (50 kHz) and the transponder (50 kHz/70 kHz) attached each one on the trawl door by measuring the time-difference of receiving with two channels receiver on the trawler. This paper assums that both the length of the warp from the stern to the trawl door is same. At results the system shows a good relation between the distance and the time-difference of receiving while the location of the pinger is moved in variously in the water tank, and it was found that the method of measuring techniques on the prototype system could be applied to the measurement of the trawl door opening in the field experiment.

  • PDF

수조모델 실험에 의한 접지저항 추정 (presumption of Earth Resistance by Water Tank Model)

  • 고희석;최종규;김주찬;이충식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.125-131
    • /
    • 2002
  • It is very important to assume potential distribution to be generated in electrode environs and grounding resistance by current beforehand, when incoming at grounding electrode to plan efficient grounding facilities In this paper, we analyzed grounding resistance through a simulation experiment by a water tank scaled model electrode of the rectangular earth plate, a theoretical Calculation result of the rectangular earth plate and measurement of grounding resistance buried rectangular earth plate analysing earth surface potential.

  • PDF

수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험 (Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water)

  • 최인수;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

메쉬접지극의 접지저항에 관한 실증연구 (An experimental research about the grounding resistance of the mesh electrode in the model of water tank)

  • 김주찬;최종규;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.349-354
    • /
    • 2005
  • Recently, there are many equipment of electricity, electronics, and communication which need to grounding in the building. When the electric current flows into a certain grounding system in the same building, the potential rise of other grounding system is possible to be affected by its potential rise. This potential interference was affected by the surface potential, it is deeply related whit the electrode shape. In this paper, basic formula is deduced on the basis of both electrodes surface potential of grounding electrode in a source of the potential interference and groundidng electrode which receive the potential interference. Therefore the degree of potential interference as multiple groundidng electrode can be verified the simulated results by means of the simple model in advance. This is for investigating the grounding resistance of grounding electrodes, the experiment was performed with model-scale of the grounding system and the scaled model grounding system was to this experiment using a water tank of a stainless steel-hemisphere shape. since mesh electrodes have been widely in the general building, we're tried to analyze that this water tank model and it's simulation as well.

  • PDF

주꾸미의 색에 대한 선택성과 단지의 개량 (Color Preference of Webfoot Octopus and Improvement of Fishing Pots)

  • 임성호;고관서;권병국
    • 수산해양기술연구
    • /
    • 제26권3호
    • /
    • pp.237-243
    • /
    • 1990
  • 본 연구는 수조실험을 통하여 주꾸미, Octopus Ocellatus GRAY의 단지색에 대한 선택성을 조사하고, 전통적인 주꾸미 단지의 재질을 고둥껍질에서 PVC로 대체할 경우 그 가능성을 규명하기 위하여 PVC 시험 단지를 제작하여 1989년부터 1990년까지 해상실험을 실시하여 어획율을 조사하였다. 실험에서 얻은 결과를 요약하면 다음과 같다. 1. 수중실험에서 적색, 녹색, 황색, 백색, 회색중에서 주꾸미가 선호하는 색은 회색, 적색, 녹색, 황색, 백색순으로 나타났다. 2. 해상실험에서 주꾸미의 선호색은 회색, 홍색, 녹색순으로 나타났고, 이것은 수조실험의 결과와 일치한다. 3. 어획성능면에서 고둥껍질과 회색 PVC 단지의 차이는 거의 없었다. 4. 직경별 어획율은 40mm PVC 단지가 1.00, 50mm가 0.19로 나타났다.

  • PDF

소형수조에서 음향재료의 반향음감소와 투과손실 측정시스템 구성 (Measurement System for Performance Evaluation of Acoustic Materials in a Small Water Tank)

  • 신미루;조정홍;이경택;김재수;전재진;함일배;강창기
    • 한국음향학회지
    • /
    • 제30권2호
    • /
    • pp.63-72
    • /
    • 2011
  • 본 논문은 반향음과 투과음을 감소시키기 위한 평판형 음향재료의 성능평가 장치를 제작하고 측정시스템을 구성하며 표준표적을 이용한 검증을 통해 신뢰성을 확보하는 데 목적이 있다. 반향음감소와 투과손실 측정은 신호간섭이 없도록 대형수조에서 실시되는 것이 일반적이지만, 본 논문에서는 신호간섭을 고려해야 하는 소형수조에서 최저 30 kHz까지 측정이 가능한 측정시스템을 구성하였다. 이를 위해 신호모의를 통해 신호간섭이 없는 최적의 기하학적 배치를 도출하였으며, 획득한 신호를 시간영역과 주파수영역의 총 네 가지 방법으로 ER과 TL을 도출하는 신호처리 알고리즘을 확립하였다. 마지막으로 대형수조에서의 전파손실 실측실험을 통해 측정시스템을 보정하고 알루미늄 판과 스티로폼을 표준표적으로 사용한 측정결과를 Brekhovskikh Layer Model과 비교하여 측정시스템 검증을 수행하였다.