A study on the Treatment of Brewhouse Wastewater using Biological Film Process (생물막법에 의한 양조폐수 처리에 관한 연구)

  • Eun, Jong-Geuk;Lee, Tae-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.59-63
    • /
    • 2003
  • This study was carried out to get efficient of organic material removal and wastage sludge production minimized effects on the treatment of Brewhouse wastewater using aerobic RBC and curtain biological film contact process. As a results of biofilm attachment experiment aggravation of water quality due to excessive biofilm showed after every 13 days of operating times. The concentration of BOD at raw wastewater was 3800${\sim}$5300 mg/L and COD was 2300${\sim}$3100 mg/L. The average BOD of effluent was maintained 18 mg/L and average COD was 26 mg/L. The result of this experiment was wastage sludge did not almost generated.

A Study of Water Curtain Nozzles Installation for Wooden Cultural Asset Protection (목조문화재 보호를 위한 수막노즐의 개발에 관한 연구)

  • Kim, Kyong-Jin;Lee, Su-Jyung;Song, Dong-Woo;Yoon, Chuel-Jea;Kim, Ji-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.537-540
    • /
    • 2011
  • 중요 목조문화재를 산불이나 인접 건축물의 화재로부터 보호하기 위한 방안으로 수막노즐을 제시하였다. 바닥으로부터 일정압력 이상으로 상승하는 물줄기로 수막을 형성하여 복사열을 차단함으로써 $200^{\circ}C{\sim}250^{\circ}C$에서 발생하는 목재의 열분해를 막기 위한 것으로 기존에 설치되어 있는 강원도 낙산사와 전라남도 무위사의 수막노즐의 설치상태를 확인해 보았고 이를 보완 개량하기 위한 방안으로 평상시 덮개에 덮인 노즐을 설치하여 경관을 손상시키지 않게 하였고 사용 시 수직상승하여 물을 분사할 수 있는 상하승강식 노즐봉과 이를 효과적으로 설치하는 방법에 대하여 연구되었다.

  • PDF

An Analysis of the Smoke Control Characteristics of Water Curtain System for Underground Space (지하 공간의 워터커튼 시스템 화재제어 특성 분석)

  • You, Woo-Jun;Nam, Jun-Seok;Choi, Jin-Jong;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.298-301
    • /
    • 2011
  • 본 연구에서는 지하 방호공간에서 화재가 발생한 경우 워터커튼 시스템에 의한 연기의 차단효과와 화재제어 특성을 분석하였다. 이를 위해서 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐과 지하방호 공간용 실화재 실험 장치를 제작하였으며, 화재강도 1.5 MW 기준 A급 1단위 화재 실험으로부터 온도분포와 가시도를 측정하여 연기의 차단효과를 확인하였다. 화재제어 특성을 분석하기 위해서 NIST(National Institute of Standards and Technology)의 해석프로그램인 FDS(Fire Dynamic Simulator)를 사용하여 동일한 실험조건에서 온도분포를 비교하였으며 노즐의 설치개수 변화에 대한 화재해석 및 실험결과로부터 워터커튼 시스템은 노즐의 설치위치와 개수, 화원으로부터의 거리, 제연 등의 설비 조건과 분사 노즐의 특성, 공급 유량 등이 중요한 상관관계를 갖고 있음을 확인하였다.

  • PDF

The design of coffer dam utilized P.R.D. method (P.R.D. 공법을 활용한 가물막이 설계)

  • Park, Chal-Sook;Lee, Kyu-Tak;Yum, Kyung-Taek;Kim, Yoon-Ku;Kang, Bong-Gwon;Lee, Jae-Weon;Lim, Seok-San;Jeong, Ji-Yearl
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.869-887
    • /
    • 2008
  • Coffer dam for tunnel type spillway in inflow section of Dae-am dam was originally planned as 2 lines sheet piles with Water Zet method. But, the result of pilot test was caused of some problems that vibration during installation of pile could pollute water and water leakage could the lower part. So, sheet piles was not satisfactory for faculty of coffer dam. Structural instability of sheet pile system need to reinforcement. Characteristic of Dae-am dam was small reservoir capacity but wide drainage area, of which it was judgment that security of leakage and stability was difficult during excavation of inlet part. So, we consider that water curtain method utilized with in site pouring concrete pile method was designed at weir part of spillway. We were known about basement rock that geological boring was carried out in weir part. After taking a deep consideration, PRD method was accepted as a new method. Concrete pile by PRD was installed to below country rock. CJM method was carried out with PRD. After making concrete wall using Top-down method, earth anchors were installed for supporting it. According to the result of numerical analysis, as water level rises, wall is stable.

  • PDF

Modeling the Effects of Curtain Weir on the Control of Algal Bloom in Daecheong Reservoir (대청호 녹조제어를 위한 수류 차단막 설치효과 수치모의)

  • Lee, Heung-Soo;Chung, Se-Woong;Jeong, Hee-Young;Min, Byeong-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.302-307
    • /
    • 2009
  • 물리적인 조류제어 기술에 해당하는 수류 차단막(이후 차단막)은 유입하천의 수류를 차단 또는 우회시켜 영양염류가 저수지의 유광층으로 공급되는 것을 차단하고 본류 수역으로의 조류 확산을 방지하는 기능이 있어 일본에서는 저수지 녹조제어 대책으로 자주 활용된 바 있다. 그러나 이러한 차단막은 국내 저수지와 같이 홍수시 유입 유속이 크고 수위변동이 심한 환경에서는 설치효과가 검증되지 않아 현장적용에 앞서 수치모의를 통한 효과 검증이 선행되어야 하며, 최적 규모와 위치 선정도 필요하다. 본 연구에서는 수위변동이 심한 국내 저수지 특성을 고려하여 차단막이 수위변화에 따라 상하로 이동할 수 있도록 기존 CE-QUAL-W2(이후W2) 모델의 알고리즘을 수정하고, 대청호에서 다양한 수리 수문조건에서 차단막의 기작과 효과를 예측하기 위해 가뭄년(2001년)과 평수년(2004, 2006년)을 대상으로 각각 모델을 적용하였다. 차단막 설치 예정지점은 소옥천 하류(7 m 깊이)와 댐으로부터 각각 14.9 km, 27.4 km 상류에 위치한 회남대교 아래 지점(10 m 깊이)과 대정리(10 m 깊이)로 가정하고, 모의 시나리오는 차단막을 설치하지 않은 경우(S-1), 소옥천 하류에 단독으로 설치한 경우(S-2), 소옥천과 대정리에 설치한 경우(S-3), 모든 지점에 설치한 경우(S-4)를 비교하였다. 차단막 설치에 따른 수문년 및 계절별 수질개선 효과(S-1에 대한 S-4 농도 저감 비)를 비교한 결과, 대청호에서 녹조문제가 가장 심각했던 2001년 6월$^{\sim}$8월 기간 동안 차단막은 봄-여름에 걸쳐 모든 비교 지점(회남, 댐, 추동, 문의수역)에서 Chl-a 농도를 최저(문의수역) 30%에서 최고(회남수역) 70% 정도 저감하는 효과를나타냈다. 평수년인 2004년과 2006년에는 강우사상에 따라 차단막 설치에 따른 Chl-a의 농도 저감 효과가 지점별로 다르게 나타났으며, 큰 강우사상이 6월, 7월, 8월에 걸쳐 골고루 발생한 2004년에 비해 7월 한 달 동안 집중된 2006년에 설치효과가 크게 나타났다. 수역별로 차단막의 설치효과를 비교해 보면, 유입수의 영향을 직접 받는 회남수역과 추동수역이 댐 앞과 문의수역에 비해 차단막 설치에 따른 Chl-a 농도의 저감 효과가 큰 것으로 나타났다. 그러나, 큰 홍수가 유입할 때 차단막 상류부에 집적된 조류의 일부가 수류의 포획(Entrainment) 기작에 의해 저수지 내부로 유입되는 것으로 확인되어 차단막 효과를 극대화하기 위해서는 홍수 전 차단막 상류부에 집적된 조류의 처리대책이 필요할 것으로 판단된다.

  • PDF

Characteristics of Seepage Water and Groundwater in Incheon Coastal LPG Storage Cavern (인천 해안 저장공동 유출수 및 주변 지하수의 수질특성)

  • Jo, Yun-Ju;Lee, Jin-Yong;Choi, Mi-Jung;Cho, Byung-Wook
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • The objective of this study was to examine the hydrogeochemical and microbiological characteristics for stable maintenance of coastal LPG storage cavern. Cavern seepage water and groundwater in the vicinity of the LPG storage cavern were sampled and analyzed (February, May, August and October 2007). Groundwater samples of propane cavern showed high pHs of 8.1~12.4 due to dissolution of cement grouting materials that had been applied during the well and cavern construction. The EC values showed distinctive seasonal variation. The negative ORP indicated reduced condition. The seepage and surrounding groundwater are classified as Na-Cl type, which represents seawater effects. All of aerobic bacteria, anaerobic bacteria, slime forming bacteria and sulfate reducing bacteria were less than 500 CFU/mL, which indicated that there was no abrupt increase of bacteria in the cavern. Therefore there exist no hydrochemical symptoms to indicate unstable conditions of the cavern operation. However, regular and continuous monitoring is essentially required.

Numerical Investigation on the Applicability of Wave-Induced Swirl Water Chamber for Wave Power Generation in Coastal Water of Korea (파력발전을 위한 파유기 회전수류 유수실의 국내 연안 적용 가능성에 대한 수치해석적 조사)

  • Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.32-42
    • /
    • 2013
  • In this paper, a wave-induced swirl water chamber (SWC) for breakwater and wave power generation is introduced and its applicability to wave power generation in the coastal waters of Korea is investigated. The SWC type of wave power generation is a way to drive a turbine using the unidirectional swirl flow that is induced in the back of a curtain wall of a breakwater due to incident waves. The typical wave characteristics are obtained by analyzing the annual statistical wave data from KHOA (Korea Hydrographic and Oceanographic Administration). A numerical analysis is carried out on the variations in the SWC entrance height, wave height, and different installation conditions. For the numerical analysis, a commercial code, Fluent based on FVM, is used. As the entrance height decreases, the mass flow rate through the entrance is rarely changed, whereas the magnitude of the flow velocity of the smaller entrance height is greater than the other ones, which is better for the formation of an SWC swirl flow inside and the flow kinetic energy at the entrance. In cases of installation conditions where a wall is place behind and under SWC, it has been shown that the mass flow rate through the entrance is greater than that in the open condition, and sufficient flow kinetic energy is generated in the entrance for wave power generation. However, the swirl flow kinetic energy is relatively small. Thus, in the future, it is necessary to study the swirl flow generation, which is affected by the SWC shape.

Water droplet generation technique for 3D water drop sculptures (3차원 물방울 조각 생성장치의 구현을 위한 물방울 생성기법)

  • Lin, Long-Chun;Park, Yeon-yong;Jung, Moon Ryul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.143-152
    • /
    • 2019
  • This paper presents two new techniques for solving the two problems of the water curtain: 'shape distortion' caused by gravity and 'resolution degradation' caused by fine satellite droplets around the shape. In the first method, when the user converts a three-dimensional model to a vertical sequence of slices, the slices are evenly spaced. The method is to adjust the time points at which the equi-distance slices are created by the nozzle array. In this method, even if the velocity of a water drop increases with time by gravity, the water drop slices maintain the equal interval at the moment of forming the whole shape, thereby preventing distortion. The second method is called the minimum time interval technique. The minimum time interval is the time between the open command of a nozzle and the next open command of the nozzle, so that consecutive water drops are clearly created without satellite drops. When the user converts a three-dimensional model to a sequence of slices, the slices are defined as close as possible, not evenly spaced, considering the minimum time interval of consecutive drops. The slices are arranged in short intervals in the top area of the shape, and the slices are arranged in long intervals in the bottom area of the shape. The minimum time interval is pre-determined by an experiment, and consists of the time from the open command of the nozzle to the time at which the nozzle is fully open, and the time in which the fully open state is maintained, and the time from the close command to the time at which the nozzle is fully closed. The second method produces water drop sculptures with higher resolution than does the first method.