• 제목/요약/키워드: Water temperature stress

검색결과 652건 처리시간 0.033초

소수력 터빈용 기계평면시일의 표면마찰형상에 따른 접촉특성 해석에관한 연구 (A Study on Contact Characteristics of Mechanical Face Seals for a Hydro-power Turbine Depending on the Rubbing Surface Geometry)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제22권3호
    • /
    • pp.119-126
    • /
    • 2006
  • In this paper, the contact behavior characteristics of a primary sealing components such as a seal ring and a seal seat has been presented for a small hydro-power turbine. Using the non-linear FEM analysis, the maximum temperature, the axial displacement, radial differences between a seal ring and a seal seat, and maximum contact normal stress have been analyzed for three optimized sealing profiles in which are designed based on the FEM analysis and Taguchi's experimental method. The three primary sealing profiles between a seal ring and a seal seat are strongly related to a leakage of a water for a hydro-power turbine and wear of a primary sealing component. The computed results show that the contact rubbing area between a seal ring and a seal seat is very important for reducing a friction heating and wear in a sealing gap, and increasing a contact normal stress in primary sealing components. Based on the FEM computation, models II and III in which have a small rubbing surface of seal rings show low dilatation of primary sealing components, and high normal contact stress between a seal ring and a seal seat. Thus, the FEM computed results recommend a short contacting width of a primary sealing component for reducing a leakage and thermal distortions, and expanding a seal life. This means that a conventional primary sealing component may be switched to a reduced sealing face of seal rings.

EFFECTS OF PROCESS INDUCED DEFECTS ON THERMAL PERFORMANCE OF FLIP CHIP PACKAGE

  • Park, Joohyuk;Sham, Man-Lung
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 추계기술심포지움논문집
    • /
    • pp.39-47
    • /
    • 2002
  • Heat is always the root of stress acting upon the electronic package, regardless of the heat due to the device itself during operation or working under the adverse environment. Due to the significant mismatch in coefficient of thermal expansion (CTE) and the thermal conductivity (K) of the packaging components, on one hand intensive research has been conducted in order to enhance the device reliability by minimizing the mechanical stressing and deformation within the package. On the other hand the effectiveness of different thermal enhancements are pursued to dissipate the heat to avoid the overheating of the device. However, the interactions between the thermal-mechanical loading has not yet been address fully. in articular when the temperature gradient is considered within the package. To address the interactions between the thermal loading upon the mechanical stressing condition. coupled-field analysis is performed to account the interaction between the thermal and mechanical stress distribution. Furthermore, process induced defects are also incorporated into the analysis to determine the effects on thermal conducting path as well as the mechanical stress distribution. It is concluded that it feasible to consider the thermal gradient within the package accompanied with the mechanical analysis, and the subsequent effects of the inherent defects on the overall structural integrity of the package are discussed.

  • PDF

Assessment of flow-accelerated corrosion-induced wall thinning in SA106 pipes with elbow sections

  • Seongin Moon;Jong Yeon Lee;Kyung-Mo Kim;Soon-Woo Han;Gyeong-Geun Lee;Wan-Young Maeng;Sebeom Oh;Dong-Jin Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1244-1249
    • /
    • 2024
  • A combination of flow-accelerated corrosion (FAC) tests and corresponding computational fluid dynamics (CFD) tests were performed to determine the hydrodynamic parameters that could help predict the highly susceptible location to FAC in the elbow section. The accelerated FAC tests were performed on a specimen containing elbow sections fabricated using commercial 2-inch carbon steel pipe. The tests were conducted at flow rates of 9 m/s under the following conditions: water temperature of 150 ℃, dissolved oxygen <5 ppb, and pH 7. Thickness reduction of the specimen pipe due to FAC was measured using ultrasonic testing. CFD was conducted on the FAC test specimen, and the turbulence intensity, and shear stress were analyzed. Notably, the location of the maximum hydrodynamic parameters, that is, the wall shear stress and turbulent intensity, is also the same location with maximum FAC rate. Therefore, the shear stress and turbulence intensity can be used as hydrodynamic parameters that help predict the FAC-induced wall-thinning rate. The results provide a method to identify locations susceptible to FAC and can be useful for determining inspection priority in piping systems.

RHEOLOGICAL PROPERTIES OF OIL/WATER EMULSION AND OIL/LIQUID CRYSTAL/WATER SYSTEMS AND THEIR CONSUMER PERCEPTION IN HAIR CARE PRODUCTS

  • Kim, Chong-Youp;Hong, Jong-Eoun;Kim, Su-Hyun;Kang, Hak-Hee
    • 대한화장품학회지
    • /
    • 제25권4호
    • /
    • pp.123-131
    • /
    • 1999
  • Liquid crystal known as a rheological barrier to coalescence of oil droplets, increases emulsion stability, water-holding capacity and promotes active material penetration to skin. Some investigation for its rheological characteristics have been reported but its relations to consumer perception have been rarely published. In this study, oil/water emulsion and oil/liquid crystal/water systems were manufactured using the same composition or Behenyltrimethylammonium chloride/Cetostearyl alcohol/Lanolin oil. and rheological properties or each system were investigated with Cone and Plate rheometer. The formation of liquid crystalline phase was observed with polarized microscope and Differential Scanning Calorimeter. Continuous shear experiment, creep, yield and water holding capacity were measured for oil/water and oil/liquid crystal/water systems. The results were compared with sensory evaluations. Oil/liquid crystal/water system showed higher,viscosity at the same shear rate. higher viscoelasticity and higher yield stress than oil/water system. These properties were expected to show good spreadability and excellent richness without waxiness in hair can: products of creme type. This expectation was consistent with the results of sensory experiments. Water-holding capacity was evaluated by measuring residual water of specimens at specific temperature and relative humidity. Oil/liquid crystal/water system was proved to have higher ability to hold water in comparison with oil/water system. The results indicated that oil/liquid crystal/water system was of benefit to rheological properties creme type hair care products.

  • PDF

PHEOLOGICAL PROPERTIES OF OIL/WATER EMULSION AND OIL/LIQUID CRYSTAL/WATER SYSTEMS AND THEIR CONSUMER PERCEPTION IN HAIR CARE PRODUCTS

  • Kim, Chongyoup;Jongeoun Hong;Kim, Suhyun;Hakhee Kang
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 1999년도 IFSCC . ASCS 학술대회 발표 논문
    • /
    • pp.123-131
    • /
    • 1999
  • Liquid crystal known as a rheological barrier to coaleseence of oil dorplets. increases. emulsion stability, water-holding capacity and promotes active material penetration to skin. Some investigation for its rheological characteristics have been reported but its relations to consumer perception have been rarely published. In this study oil/water emulsion and oil/liquid crystal/water systems were manufactured using the same composition of Behenyltrimethylammonium chloride/Cetostearyl alcohol/Lanolin oil. and rheological properties of each system were investigated with Cone and Plate rheometer. The formation of liquid crystalline phase was observed with polarized microscope and Differential Scanning Calorimeter. Continuous shear experiment, creep yield and water holding capacity were measured for oil/water and oil/liquid crystal/water systems. The results were compared with sensory evaluations. Oil/liquid crystal/water system showed higher viscosity at the same shear rate, higher viscoelasticity and higher yield stress than oil/water system. These properties were expected to show good spreadability and excellent richness without waxiness I hair care products of creme type. This expectation was consistent with the results of sensory experiments. Water-holding capacity was evaluated by measuring residual water of specimens at specific temperature and relative humidity, Oil/liquid crystal/water system was proved to have ability to hold water in comparison with oil/water system. The results indicated that oil/liquid crystal/water system was of benefit to rheological properties creme type hair care products.

  • PDF

Approximate estimation of soil moisture from NDVI and Land Surface Temperature over Andong region, Korea

  • Kim, Hyunji;Ryu, Jae-Hyun;Seo, Min Ji;Lee, Chang Suk;Han, Kyung-Soo
    • 대한원격탐사학회지
    • /
    • 제30권3호
    • /
    • pp.375-381
    • /
    • 2014
  • Soil moisture is an essential satellite-driven variable for understanding hydrologic, pedologic and geomorphic processes. The European Space Agency (ESA) has endorsed soil moisture as one of Climate Change Initiates (CCI) and had merged multi-satellites over 30 years. The $0.25^{\circ}$ coarse resolution soil moisture satellite data showed correlations with variables of a water stress index, Temperature-Vegetation Dryness Index (TVDI), from a stepwise regression analysis. The ancillary data from TVDI, Land Surface Temperature (LST) and Normalized Difference Vegetation Index (NDVI) from MODIS were inputted to a multi-regression analysis for estimating the surface soil moisture. The estimated soil moisture was validated with in-situ soil moisture data from April, 2012 to March, 2013 at Andong observation sites in South Korea. The soil moisture estimated using satellite-based LST and NDVI showed a good agreement with the observed ground data that this approach is plausible to define spatial distribution of surface soil moisture.

운전이력을 고려한 지역난방 열배관의 피로수명 평가 및 최적화 (Fatigue Life Evaluation and Optimization for District Heating Pipes Considering Operating Temperature Transition Data)

  • 안민용;정성욱;이상민;장윤석;최재붕;김영진;김상호;김연홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2005
  • A district heating(DH) system supplies environmentally-friend heat and is appropriate for reduction of energy consumption and/or air pollutions. The objectives of this paper are to systematize data processing of transition temperature, investigate its effects on fatigue life of DH pipes and optimization for size of DH pipes. A relational database management system as well as reliable fatigue life evaluation procedures is established for Korean DH pipes. Also, since the prototypal evaluation results satisfied both cycle-based and stress-based fatigue criteria. Through the optimum design process, the cross section diminished 18.64% and the CUF diminished 23.35%. So, it can be used as useful information in the future for optimal design, operation and energy saving via setting of efficient condition and stabilization of water temperature.

  • PDF

12Cr 합금강의 부식특성 및 인공열화된 12Cr합금강의 피로특성 (Corrosive Characterisics of 12Cr Alloy Steel and Fatigue Characteristics of the Artificially Degraded 12Cr Alloy Steel)

  • 조선영;김철한;배동호
    • 대한기계학회논문집A
    • /
    • 제25권6호
    • /
    • pp.965-971
    • /
    • 2001
  • To estimate the reliability of 12Cr alloy steel, the material of turbine blade in the steam power plant, Its corrosion susceptibility and fatigue characteristics in NaCl and Na$_2$SO$_4$solution with the difference of concentration and temperature was investigated. The polarization tests recommended in ASTM G5 standard for corrosion susceptibility in the various corrosive solutions was estimated. It showed that the higher temperature, the faster corrosion rates and corrosion rates were the fastest in 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution. From these results, the degradation conditions were determined in distilled water, 3.5 wt.% NaCl and 1M Na$_2$SO$_4$solution at room temperature, 60$\^{C}$ and 90$\^{C}$ during 3, 6 and 9 months. Its surface had a few pits for long duration. But, it was not susceptible in sulfide and chloride condition of several temperatures. If the degraded 12Cr alloy steel and non-degraded one were compared with fatigue characteristics, Any differences were not found regardless of temperature and degradation period.

LARGE SCALE FINITE ELEMENT THERMAL ANALYSIS OF THE BOLTS OF A FRENCH PWR CORE INTERNAL BAFFLE STRUCTURE

  • Rupp, Isabelle;Peniguel, Christophe;Tommy-Martin, Michel
    • Nuclear Engineering and Technology
    • /
    • 제41권9호
    • /
    • pp.1171-1180
    • /
    • 2009
  • The internal core baffle structure of a French Pressurized Water Reactor (PWR) consists of a collection of baffles and formers that are attached to the barrel. The connections are done thanks to a large number of bolts (about 1500). After inspection, some of the bolts have been found cracked. This has been attributed to the Irradiation Assisted Stress Corrosion Cracking (IASCC). The $Electricit\acute{e}$ De France (EDF) has set up a research program to gain better knowledge of the temperature distribution, which may affect the bolts and the whole structure. The temperature distribution in the structure was calculated thanks to the thermal code SYRTHES that used a finite element approach. The heat transfer between the by-pass flow inside the cavities of the core baffle and the structure was accounted for thanks to a strong thermal coupling between the thermal code SYRTHES and the CFD code named Code_Saturne. The results for the CP0 plant design show that both the high temperature and strong temperature gradients could potentially induce mechanical stresses. The CPY design, where each bolt is individually cooled, had led to a reduction of temperatures inside the structures. A new parallel version of SYRTHES, for calculations on very large meshes and based on MPI, has been developed. A demonstration test on the complete structure that has led to about 1.1 billion linear tetraedra has been calculated on 2048 processors of the EDF Blue Gene computer.

매듭풀 ( Kummerowia striata ( Thunb. ) Schindl. ) 개체군의 질소고정활성과 생육특성의 계절변화 (Seasonal changes of nitrogen fixation and growth characteristics of kummerowia striata(thunb)schindl. populations)

  • Song, Seung-Dal;Bae, Sang-Mee
    • The Korean Journal of Ecology
    • /
    • 제15권4호
    • /
    • pp.377-386
    • /
    • 1992
  • Seasonal changes of symbiotic nitrogen-fixation activity and growth characteristics of four different natural populations of kummerowia striata were quantitatively analyzed during the growing period. the nitrogen-fixation activity of root nodules attained the maximum rates of 148, 132, 102 and 100$\muM\;C_2H_4\;\cdot\;g\;fw\;nodule^{-1}\;\cdot\;hr^{-1}$, respectively for sunny, multibranched, shade and unibranched populations at the optimum growth conditions. and the seasonal changes showed fluctuations by environmental conditions such as light, temperature, nutrient contents, water stress and plant ages, etc. The multibranched plant showed the greater amount of leaf and root nodule biomass, and the higher nitrogenase activity than the unibranched plant. the optimum conditions of leaf chloropht11 and water content of each organ indicated the active growth and the maximum fresh biomass of 4 different populations were 1.92, 1.85, 0.97 and 0.56 g $fw\cdotplant^{-1}$ for shade multibranched, sunny and unibranched populations, respectively.

  • PDF