• Title/Summary/Keyword: Water supply pipelines

Search Result 48, Processing Time 0.023 seconds

A Numerical Method to Calculate Drainage Time in Large Transmission Pipelines Filter (대구경 관로의 배수시간 산정을 위한 수치해석 기법)

  • Shin, Byoung-Ho;Choi, Doo-Yong;Jeong, Kwansue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.511-519
    • /
    • 2017
  • Multi-regional water supply system, which installed for supplying multiple water demands, is characterized by large-sized, long-distance, tree-type layout. This system is vulnerable to long-standing service interruption when a pipe breaks is occurred. In this study, a numerical method is proposed to calculate drainage time that directly affects time of service interruption. To begin with, governing equations are formulated to embed the delayed drainage effect by the friction loss, and to resolve complicated connection of pipelines, which are derived from the continuity and energy equations. The nonlinear hydraulic equations are solved by using explicit time integration method and the Newton-Raphson method. The developed model is verified by comparing the result with analytical solution. Furthermore, the model's applicability is validated by the examples of pipelines in serial, in parallel, and complex layout. Finally, the model is utilized to suggest an appropriate actions to reduce the deviation of draining time in the C transmission line of the B multi-regional water supply system.

A Study on the Development and Applicative Estimation of Safety Evaluation Model for Water Supply Pipelines using Quantification Theory Type II (수량화II류이론을 활용한 상수도관로의 안전성 평가 모델 개발 및 적용성 평가 연구)

  • Kim, Kibum;Shin, Hwisu;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • Owing to time and cost constraints, new methods that would make it possible to evaluate the safety of the water supply pipeline in a less time- and cost-consuming manner are urgently needed. In response to this exigency, the present study developed a new statistical model to assess the safety of the water supply pipeline using the quantification theory type II. In this research, the safety of the water supply pipeline was defined as 'a possibility of the pipeline failure'. Quantification analysis was conducted on the qualitative data, such as pipe material, coating, and buried condition. The results of analyses demonstrate that the hit ratio of the quantification function amounted to 77.8% of hit ratio, which was a fair value. In addition, all variables that were included in the quantification function were logically valid and demonstrated statistically significant. According to the results derived from the application of the safety evaluation model, the coefficient of determination ($R^2$) between K-region's water supply pipeline safety and the safety inspection amounted to 0.80. Therefore, these findings provide meaningful insight for the measured values in real applications of the model. The results of the present study can also be meaningfully used in further research on safety evaluation of pipelines, establishing of renewal prioritization, as well as asset management planning of the water supply infrastructure.

Behavior Characteristics of Water Supply Pipeline Due to Freezing Temperature (동결온도가 상수도관의 거동에 미치는 영향)

  • Shin, Eun Chul;Ryu, Byung Hyun;Kang, Hyoun Hoi;Hwnag, Soon Gab
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.1-10
    • /
    • 2014
  • This paper presents the results of a field pilot test about deformation of water supply pipelines due to freezing temperature. There is a difference between for frost heaving load to act on the water supply pipelines. If the Marston-Spangler theory is only considered for the frost heaving load to act on the water supply pipeline, it is likely to deviate from the safety of the water supply pipeline, strains of the water supply pipeline show a tendency of smaller value than the value of numerical analysis.

A research on the design parameters for a double-transmission main system for sustainable water supply (이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구)

  • Hyun, Inhwan;Hong, Juneui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Automatic control problems of VVVF converter-based variable-frequency type air (VVVF기를 기초한 가변식기압급수설비의 자동제어 문제)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF

Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation (주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.44-52
    • /
    • 2014
  • Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ~ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.

A review on vibration-based structural pipeline health monitoring method for seismic response (지진 재해 대응을 위한 진동 기반 구조적 관로 상태 감시 시스템에 대한 고찰)

  • Shin, Dong-Hyup;Lee, Jeung-Hoon;Jang, Yongsun;Jung, Donghwi;Park, Hee-Deung;Ahn, Chang-Hoon;Byun, Yuck-Kun;Kim, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.335-349
    • /
    • 2021
  • As the frequency of seismic disasters in Korea has increased rapidly since 2016, interest in systematic maintenance and crisis response technologies for structures has been increasing. A data-based leading management system of Lifeline facilities is important for rapid disaster response. In particular, the water supply network, one of the major Lifeline facilities, must be operated by a systematic maintenance and emergency response system for stable water supply. As one of the methods for this, the importance of the structural health monitoring(SHM) technology has emerged as the recent continuous development of sensor and signal processing technology. Among the various types of SHM, because all machines generate vibration, research and application on the efficiency of a vibration-based SHM are expanding. This paper reviews a vibration-based pipeline SHM system for seismic disaster response of water supply pipelines including types of vibration sensors, the current status of vibration signal processing technology and domestic major research on structural pipeline health monitoring, additionally with application plan for existing pipeline operation system.

A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems (송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

Buckling of Buriend Pipelines due to Seismic Waves (지진파에 의한 매설관로의 좌굴)

  • 이종세
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.109-118
    • /
    • 1999
  • Lifeline system such as oil or gas pipelines and water supply facilities are vulneratble to seismic damages because they are widely exposed to ground failures. Most seismic design criteria of buried pipelines are based on the notion that the longitudinal compressive strain and therefore buckling controls the design. Buckling analysis of buried pipelines subjected to seismic loading is performed by considering the seismic load as the sinusoidally distributed compressive load on the beam on elastic foundation in contrast to existing studies where the buckling load is treated as an end load on the beam column, An approximated analytical solution is obtained by the energy method and its validity is confirmed by the linearized finite element buckling analysis. The results show the beam mode buckling because longitudinal strains at the buckling loads are substantially lower than the strain at the onset of local buckling.

  • PDF