• Title/Summary/Keyword: Water sensitive paper

Search Result 134, Processing Time 0.031 seconds

Transmission Performance of MANET on 3D Underwater Communication Environments (3D 수중통신환경에서 MANET의 전송성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.997-1002
    • /
    • 2017
  • Underwater communication, which is used acoustic channel of 1500[m/s] speed being different of wireless electric wave in terrestrial communication, is sensitive on water temperature and salinity and also affected from 3D underwater space. 3D underwater communication is sensitive on propagation loss of acoustic wave and underwater noise with complexity of communication space. In this paper, transmission performance with consideration of these characteristics of 3D underwater communication environments is measured and analyzed on MANET operated on 3D underwater communication environments. Some underwater MANET operation conditions will be suggested. Computer simulation with underwater simulator based on NS-2 will be used for performance measure, performance parameter like as throughput, transmission delay, packet loss rate and consumed energy will be used in simulation for performance measure.

Electrochemical Monitoring of NADH Redox with NPQD-modified Electrodes for Cell Viability Assessment

  • JuKyung Lee;Hye Bin Park;Chae Won Seo;Chae Won Seo;SangHee Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.412-417
    • /
    • 2023
  • There is increasing interest in the rapid and highly sensitive monitoring of cell viability in biological and toxicological research. Conventional methods depend on optical assays using Water Soluble Tetrazolium-8 (WST-8) or 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide (MTT) assay, which requires a large volume of samples and special instruments, necessitating shipment of clinical samples to laboratories. This paper reports on the development of a rapid and sensitive electrochemical (EC) sensor using screen printed electrode (SPE) and surface modification using 4'-mercapto-N-phenylquinone diamine (4'-NPQD), as double electron mediators, for monitoring cell viability via the measurement of nicotinamide adenine dinucleotide (NADH). We used the sensor to observe the viability of MCF-7 and doxorubicin (Dox)-treated cells. The oxidation current of NADH was measured via chronoamperometry (CA), and the EC results showed a good linear relationship when compared with NADH quantification using WST-8 assay. The analysis time was only 10 s and limit of detection (LOD) of NADH was 1.78 µM. Our EC method has the potential to replace conventional WST assays for cell viability and cytotoxicity experiments.

A Study on the Variation of Optical Fiber Splicing Loss due to Environment (광섬유 접속부의 환경 변화에 따른 손실변화 연구)

  • Kim Young-Ho;Yoo Kang-Hee
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.105-110
    • /
    • 2006
  • The most sensitive part of the installed optical cable is the optical loss variation of the splicing point according to the environmental changes. This paper presents the details of the experimental results of the external environmental changes on optical loss, such as bending, temperature variation, temperature variation after water osmosis and variation. Through the bending test of optical fiber, rapid increase of optical loss was measured within the diameter of 30mm. The result of optical loss variation within the temperature range of $-30^{\circ}C{\sim}60^{\circ}C$ is less than 0.02dB. It was confirmed that the maximum optical loss increased up to 0.2dB in case of water osmosis within the temperature range of $-40^{\circ}C{\sim}80^{\circ}C$. There is small optical loss variation of 0.01dB under the 1mm vibration test. The experimental results of this paper can be used as the reference data for the design of the optical fiber cable splicing enclosure to protect the optical loss variation due to environmental changes.

  • PDF

Heat transport characteristics by heat generation of electrochemical reactions in proton exchange membrane fuel cell (고분자전해질 연료전지에서 전기화학반응 열생성에 의한 열전달특성)

  • Cho, Son-Ah;Lee, Pil-Hyong;Han, Sang-Seok;Hwang, Sang-Soon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3377-3382
    • /
    • 2007
  • In proton exchange membrane fuel cell, the heat is generated at the catalyst layer as result of exothermic electrochemical reaction. This heat increases temperature of gas diffusion layer and membrane whose conductivity is very sensitive to humidity, function of temperature. So it is very important to analysis heat transfer through fuel cell to maintain temperature at specified range. In this paper numerical simulation was done including reversible, irreversible, ionic resistance, water formation loss to source term of energy equation. Results show that irreversible and water formation loss contributes mainly to energy source term and as current density increases, all of energy source terms become increased and Nusselt number is increased as results of more heat generation. Particularly irreversible loss is found to be predominant among the all energy source and water formation at cathode channel influences the temperature distribution of fuel cell greatly.

  • PDF

Life-cycle Cost Analysis of Using Rainwater Harvesting Systems in Hong Kong Residential Buildings (홍콩 주거건물에서 우수활용시스템의 생애주기비용분석)

  • Gao, Xing;Kim, Youngchul;Lee, Hyun Woo
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.53-62
    • /
    • 2014
  • This paper investigates whether the use of Rainwater Harvesting Systems (RWHSs) to provide water for washing machines in Hong Kong residential buildings would be financially attractive. In such systems, rainwater is accumulated and reused for doing laundry, garden irrigation, flushing toilets, and even drinking. Thus, the analysis of RWHSs' financial feasibility is essential for construction projects. RainCycle is used to validate financial feasibility, considering particular circumstances and data relevant to the Hong Kong context. A range of different scenarios by adjusting three factors are evaluated: catchment area, water demand, and discount rate. It is suggested that $2,000m^2$ would be a suitable catchment area in a typical Hong Kong residential building and it is demonstrated how water demand and discount rate influence the financial performance of RWHSs. In particular, the financial performance of RWHSs is sensitive to discount rates. The results suggest that the RWH system would be worthwhile for buildings with a lower number of floors, but would barely achieve financial validation in Hong Kong's super high-rise residential buildings.

Growth Inhibition of Food-borne Bacteria by Juice and Extract of Ginger and Garlic (생강과 마늘 즙 및 추출물의 식중독 세균에 대한 증식저해작용)

  • 김미림;최경호;박찬성
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.10 no.2
    • /
    • pp.160-169
    • /
    • 2000
  • This study was conducted to understand the inhibitory garlic and ginger against the growth of food born pathogenic bacteria. Juice was prepared from the raw spices by using an electric homogenizer and membrane filter. Dry-powdered spices were treated with double distilled water and 70% ethanol to extract the antibacterial substances, respectively. Growth inhibitory effects of juice and extracts of the spices were monitored by using bacterial strains such as B. subtilis, L. moncytogenes, S. aureus,E. coli O157 : H7, P. aeruginosa, and S. typhimurium. On a solid medium where E. coli and S. aureus cells were grown, ginger juice formed inhibitory zone at the concentrations of 2-10% by paper disc test. The Bone formed by ginger juice was wider and more transparent than that formed by garlic juice on the same concentration.1. monocytogenes and B. subtilis were more sensitive to garlic juice than others, and stopped growing at 2% garlic juice. Ginger juice showed the growth inhibition by 30-50% at 1.0% concentration. On the contrast, P. aeruginosa which resisted to the garlic juice was the most sensitive to ginger juice. Water extract of garlic was not effective to inhibit the bacterial growth, while 2% ginger extract completely inhibited the growth of E. coli and S. aureus. Alcohol extract of ginger inhibited the growth of bacteria at the concentration of 0.3%. This growth inhibition is almost 10 times lower than that of the garlic extract. It was clear that ginger had more potential than garlic as an inhibitor to control the growth of the indicator organisms.

  • PDF

Analysis of Behavior Characteristics of Instantaneous Input of Pollutant in River (하천에 순간 유입된 오염물질의 거동 특성 분석)

  • Yoon, Sei-Eui;Ko, Jae-Hyung;Kim, Soo-Youl
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.4
    • /
    • pp.575-586
    • /
    • 2003
  • In case of continuous input of a pollutant, dispersion characteristics do not change much with changing dispersion coefficient, but that of an instantaneous input is very sensitive to the changes of dispersion coefficient. The characteristics of behavior of instantaneous input of a pollutant at the downstream of Han river were analyzed in this paper Field measurement of hydraulic and water quality factors at the downstream of Han river were conducted at low flow condition. The hydraulic factors were used to estimate the longitudinal dispersion coefficient, and the reasonable empirical equations for longitudinal dispersion coefficient at the downstream of Han river were suggested. The measured concentrations of BOD were closely matched with the calculated ones from RMA-4 model. In case of instantaneous input, range of dispersion, transport pathway and the traveltimes of the first and maximum concentration with variation of the longitudinal dispersion coefficients and water levels of downstream boundary were evaluated in this paper.

Evaluation of Effluent Toxicity which were Exempted from Applying of Ecotoxicity Criteria (생태독성기준 미적용 업종 사업장 배출수 생태독성 수준 평가)

  • Kim, Jongmin;Shin, Kisik;Lee, Soohyung;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.197-202
    • /
    • 2017
  • This paper aimed to evaluate the test results of acute toxicity on effluent samples which were exempted from applying of ecotoxicity criteria. Total 316 effluent samples which were free from controlling of ecotoxicity regulation, were tested. Ratio of effluent samples which were exceeded the ecotoxicity criteria (TU > 1) indicated 23.7%. This ratio was a little bit higher than previous study (22.7%) on effluent samples which were controlled under ecotoxicity criteria. These results mean that our ecotoxicity management system is not appropriate and applying of ecotoxicity criteria to all effluent samples (82 industry categories) were needed in order to improve our ecotoxicity system. In addition, the same numeric criteria (TU 1 or 2) for all industry categories were proposed in consideration of these results. Ratio of effluent samples which exceeded the ecotoxicity criteria (TU > 1) with D. magna indicated 23.7%. However V. fischeri showed 14.6%. As a acute toxicity test organism, D. magna seemed to be more sensitive than V. fischeri. Ratio of samples which were exceeded TU 1 with D. magna by 24 h exposure period test indicated 35 %, whereas 48 h showed 41%.

An Evaluation of Snowmelt Effects Using SWAT in Chungju Dam Basin (SWAT을 활용한 충주댐 유역의 융설 영향 평가)

  • Kim, Nam-Won;Lee, Byong-Ju;Lee, Jeong-Eun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.10 s.171
    • /
    • pp.833-844
    • /
    • 2006
  • The objective of this study is to evaluate the snowmelt effects on the hydrological components, especially on the runoff, by using the soil water assessment tool(SWAT) which is a continuous semi-distributed long term rainfall-runoff model. The model was applied to the basin located in the upstream of the Chungju Dam. Some parameters in the snowmelt algorithm were estimated for the Chungju basin in order to reflect the snowmelt effects. The snowmelt effects were assessed by comparing the simulated runoff with the observed runoff data at the outlet of the basin. It was found out that the simulated runoff with considering the snowmelt component matches more satisfactorily to the observed one than without considering snowmelt effect. The simulation results revealed that the snowmelt effects were noticeable on March and April. Similar results were obtained at other two upstream gauging points. The effect of the elevation bands which distribute temperature and precipitation with elevation was analyzed. This study also showed that the snowmelt effect significantly affects the temporal distribution as well as quantity of the hydrological components. The simulated runoff was very sensitive to the change of temperature near the threshold temperature which the snowmelt can occur. However, the reason was not accounted for this paper, Therefore, further analyses related to this feature are needed.

Researched and Analyzed Variables for Pollution Waters around the "Kosova B" Thermal Power Plant

  • Musliu, Adem;Musliu, Arber;Baftiu, Naim
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.9
    • /
    • pp.109-116
    • /
    • 2022
  • The energy corporation of Kosovo continuously monitors and analyzes the impact of its own activities on the environment. Regarding the environmental situation, energy corporation of Kosovo- ECK regularly informs and reports objectively to the competent state institutions, local municipal institutions and interested parties. ECK, through numerous contacts with the competent authorities, firstly with different ministers, harmonizes the positions regarding environmental issues in the direction of achieving certain environmental standards or legal requirements in order to gradually be in accordance with them, based on the real possibilities, especially the financial ones. From this point of view, the environmental issue is very sensitive, quite complex and represents one of the biggest challenges of society currently and in the future. The researched variables show a continuous increase in the need for electricity production in Kosovo and this increase in production conditions a wide range of environmental impacts both at the local, regional and global levels. The aim of the work is to reduce the emission of pollutants through the main variables without inhibiting the economic development of the country, i.e. to bring the pollution as a result of the activities of the ECK operation into compliance with the permitted environmental norms. As a result of ECK's operational activities, the following follows: Air pollution mainly as a result of emissions from TCs in the air, transport, etc. Water pollution - as a result of technological water discharges, Land degradation - as a result of surface mining activities of the entire mining area. The purpose of the paper is to research and analyze the main water variables in the area of the Kosova B power plant, which is to determine the degree of their pollution from the activities of the power plants, as well as to assess the real state of surface water quality and control the degree of pollution of these waters. Methodology of the work: The analyzes of the water samples were done in the company Institute "INKOS" JSC by simultaneous methods using different reagents.