• Title/Summary/Keyword: Water sampling

Search Result 1,260, Processing Time 0.03 seconds

Modified Direct-Sampling GLC Method to Study Warmed-Over Flavor Related Volatiles (휘발성(揮發性) Warmed-Over Flavor의 연구(硏究)를 위한 변형(變形)된 Direct Sampling GLC법(法))

  • Shin-Lee, Seung-Yee;Rhee, Chong-Ouk
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.562-568
    • /
    • 1990
  • The modified direct GLC method was evaluated for analysis of volatile compounds associated with WOF of cooked meat. This modified method was pertaining to collection of volatiles from the samples that contain quantities of water. The modification was appropriate for the studies of low molecular weight saturated aldehydes (C5-C15), unsaturated aldehydes (C5-C9), and saturated alcohols (C5-C9).

  • PDF

Performance of a Passive Ranging by Using Dual Focused Beamformers (이중 초점 빔 형성기를 사용한 수동형 거리 추정 기법의 성능)

  • 김준환;양인식;김기만;오원천;김인익;천승용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.52-57
    • /
    • 2001
  • The passive ranging estimation techniques using a focused beamformer have been studied under the water. It is well known that the passive ranging estimation method using a focused beamformer is excellently evaluated. Among these, the passive ranging sonar is known to have a good performance under low signal-to-noise. ratio. However, its performance is degraded in multi-source environments. In this paper, we proposed the technique using dual focused beamformers to estimate the range. And when the sampling frequency is low, it is very difficult to steer the focused beam to the desired direction, as a result of this, the low performance occurs because of a distorted beam pattern. In this paper, we study the effect of sampling rate on passive ranging by using focused beamformer. And we verified the performance of the proposed method via computer simulation.

  • PDF

Long-Term Monitoring of Noxious Bacteria for Construction of Assurance Management System of Water Resources in Natural Status of the Republic of Korea

  • Bahk, Young Yil;Kim, Hyun Sook;Rhee, Ok-Jae;You, Kyung-A;Bae, Kyung Seon;Lee, Woojoo;Kim, Tong-Soo;Lee, Sang-Seob
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.10
    • /
    • pp.1516-1524
    • /
    • 2020
  • Climate change is expected to affect not only availability and quality of water, the valuable resource of human life on Earth, but also ultimately public health issue. A six-year monitoring (total 20 times) of Escherichia coli O157, Salmonella enterica, Legionella pneumophila, Shigella sonnei, Campylobacter jejuni, and Vibrio cholerae was conducted at five raw water sampling sites including two lakes, Hyundo region (Geum River) and two locations near Water Intake Plants of Han River (Guui region) and Nakdong River (Moolgeum region). A total 100 samples of 40 L water were tested. Most of the targeted bacteria were found in 77% of the samples and at least one of the target bacteria was detected (65%). Among all the detected bacteria, E. coli O157 were the most prevalent with a detection frequency of 22%, while S. sonnei was the least prevalent with a detection frequency of 2%. Nearly all the bacteria (except for S. sonnei) were present in samples from Lake Soyang, Lake Juam, and the Moolgeum region in Nakdong River, while C. jejuni was detected in those from the Guui region in Han River. During the six-year sampling period, individual targeted noxious bacteria in water samples exhibited seasonal patterns in their occurrence that were different from the indicator bacteria levels in the water samples. The fact that they were detected in the five Korea's representative water environments make it necessary to establish the chemical and biological analysis for noxious bacteria and sophisticated management systems in response to climate change.

The Validation of Landsat TM Band Ratio Algorithm using In-water Optical Measurement (수중 광학측정을 이용한 Landsat TM 밴드비율 알고리듬 검증)

  • Jeong, Jong-Chul
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.4 no.1
    • /
    • pp.18-26
    • /
    • 2001
  • Landsat TM band ratio algorithms were made by in-water optical measurement data of each sampling points for water quality monitoring of coastal area using Landsat TM satellite data. The algorithm was derived from in-water optical reflectance data which was measuring by the PRR(profiling reflectance radiometer). And, in-water optical reflectance data were applied to Landsat TM bands. Relationship between in-water optical reflectance and pigments proposed by the ratio of TM band 1 and band 2 showed to as follows; $Y=3.8352{\times}(R(band\;1)/R(band\;2))^{-2.1978}$ ($R^2$=0.7069) and, relationship of the ratio of TM band 1 and band 3 as follows; $Y=23.288{\times}(R(band\;1)/R(band\;3))^{-1.5243}$ ($R^2$=0.8062). Calculated the upwelling radiance of water surface and radiance of TM showed the ratio of atmospheric effect. In the coastal area Rayleigh and Mie scattering of atmosphere is to make over 80% of normalized radiance of Landsat TM. In order to apply in-water algorithm obtained by PRR, we had to calculate the atmospheric effects at sampling site. And, the quantitative analysis of in-water components using Landsat TM data need the calibration of in-water algorithm and effective method of atmospheric correction.

  • PDF

Effect of ammonia nitrogen and microorganisms on the elevated nitrogenous biochemical oxygen demand (NBOD) levels in the Yeongsan river in Gwangju (광주지역 영산강의 NBOD 발생에 대한 암모니아성 질소 및 미생물 영향 연구)

  • Jang, Dong;Cho, Gwangwoon;Son, Gyeongrok;Kim, Haram;Kang, Yumi;Lee, Seunggi;Hwang, Soonhong;Bae, Seokjin;Kim, Yunhee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.2
    • /
    • pp.81-95
    • /
    • 2022
  • The present study was performed to investigate the effects of NH3-N and nitrifying microorganisms on the increased BOD of downstream of the Yeongsan river in Gwangju. Water samples were collected periodically from the 13 sampling sites of rivers from April to October 2021 to monitor water qualities. In addition, the trends of nitrogenous biochemical oxygen demand (NBOD) and microbial clusters were analyzed by adding different NH3-N concentrations to the water samples. The monitoring results showed that NH3-N concentration in the Yeongsan river was 22 times increased after the inflow of discharged water from the Gwangju 1st public sewage treatment plant (G-1-PSTP). Increased NH3-N elevated NBOD levels through the nitrification process in the river, consequently, it would attribute to the increase of BOD in the Yeongsan river. Meanwhile, there was no proportional relation between NBOD and NH3-N concentrations. However, there was a significant difference in NBOD occurrence by sampling sites. Specifically, when 5 mg/L NH3-N was added, NBOD of the river sample showed 2-4 times higher values after the inflow of discharged water from G-1-PSTP. Therefore, it could be thought other factors such as microorganisms influence the elevated NBOD levels. Through next-generation sequencing analysis, nitrifying microorganisms such as Nitrosomonas, Nitroga, and Nitrospira (Genus) were detected in rivers samples, especially, the proportion of them was the highest in river samples after the inflow of discharged water from G-1-PSTP. These results indicated the effects of nitrifying microorganisms and NH3-N concentrations as important limiting factors on the increased NBOD levels in the rivers. Taken together, comprehensive strategies are needed not only to reduce the NH3-N concentration of discharged water but also to control discharged nitrifying microorganisms to effectively reduce the NBOD levels in the downstream of the Yeongsan river where discharged water from G-1-PSTP flows.

Analysis of BOD Mean Concentration and Confidence Interval using Bootstrap Technique (Bootstrap 기법을 이용한 BOD 평균 농도 및 신뢰구간 분석)

  • Kim, Kyung Sub
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.297-302
    • /
    • 2010
  • It is very important to know mean and confidence interval of water-quality constituents such as BOD for water-quality control and management of rivers and reservoirs effectively. The mean and confidence interval of BOD at Anseong2 and Hwangguji3 sampling stations which are located at the border of local governments in Anseong Stream were estimated and analyzed in this paper using Bootstrap technique which is one of non-parametric statistics. The results of Bootstrap were compared with arithmetic mean, geometric mean, Biweight method mean as a point estimator and distribution mean came from the appropriate probability distribution of Log-normal. In Bootstrap technique 12 data set was randomly selected in each year and 1000 samples was produced to get parameter of population. Visual Basic for Applications (VBA) of Microsoft Excel was utilized in Bootstrap. It was revealed that the Bootstrap technique can be used to explain more rigorously and robustly the achievement or violation of BOD target concentration in Total Maximum Daily Load (TMDL).

Analysis of Water Quality Characteristics in a Small-Scale Livestock Watershed (축산유역 수질특성 분석)

  • Choi, Yoon-Sun;Hong, Seong-Gu
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.465-468
    • /
    • 2002
  • Land application is one of the desirable management practices for animal wastes. Majority of livestock farms adopt composting and land applications for the management of animal waste in this country. Meanwhile, there are only a few studies related with the effects of land application on pollutant loading. This study investigates the water quality characteristics in a rural watershed with intensive livestock farming. The results indicate that major constituents of water quality are substantially increased at the sites near livestock farms and compost incorporated fields during the rainfall-runoff periods. There are no significant differences of water quality parameters among the sampling sites during no rain periods.

  • PDF

Loading characteristics of Total Phosphorus and Total Nitrogen from the Juam Lake Watershed (주암호 유역의 총인과 총질소 부하 특성)

  • Yoon, Kwang-Sik;Han, Kuk-Heon;Choi, Soo-Myung;Jung, Jae-Woon;Cho, Jae-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.631-634
    • /
    • 2003
  • A subwatershed within the Lake Juam was monitored to identify hydrologic and water quality characteristics. Rainfall record was collected and flow rate measurement and water quality sampling were conducted periodically at the watershed outlet. Water quality of storm period was worse than that of base flow period. Nutrient loading from the watershed was governed by only a few storms during study period. Nonpoint source pollution was identified major problem for water quality management in Juam Lake.

  • PDF

Studies on the Mineral Water in Seoul Area (서울시 일원 약수의 수질에 관한 조사연구)

  • Choi Han-Young
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.1 s.4
    • /
    • pp.69-74
    • /
    • 1988
  • This study was carried out to investigate water quality and pollution in the mineral water located in Seoul area. 15 sites were pointed out by random sampling and tested monthly for 14 items from July to December in 1986. 1. 14 sites were suitable for the drinking water standards but 1 site was not suitable for its pH (5.4). 2. The range of mineral element and concentration were as follows: $$K\;(1.1\pm0.19\~2.38\pm0.45ppm)$$ $$Na\;(5.14\pm0.32\~11.2\pm0.58ppm)$$ $$Ca\;(4.36\pm0.53\~14.44\pm0.53ppm)$$ $$Mg(1.58\pm0.32\~6.34\pm0.77ppm)$$ 3. Among the heavy metals, Fe, Zn, Mn, Cu, were detected small amount but Pb was not detected in all sample. 4. Fluoride concentrations were the range of $0.13\pm0.03\~0.42\pm0.03ppm$.

  • PDF

Monitoring water injection with borehole ERT: preliminary results of an experiment carried out in Sindos (N. Greece)

  • Tsourlos, Panagiotis;Kim, Jung-Ho;Vargemezis, George;Yi, Myeong-Jong
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.87-92
    • /
    • 2007
  • This work describes the installation and preliminary measurements of an electrical resistivity tomography (ERT) system to monitor the injection of recycled water into a confined aquifer in the area of Sindos (Thessaloniki N. Greece). The aim is to provide, through time-lapse ERT measurements and processing, geoelectrical images of rather increased volumetric sampling around and between the holes and to obtain improved understanding of the flow and transport of the injected water. The details about the general setting, the construction and installation of the ERT cables into the boreholes are explained in full. Preliminary measurements involving single and cross-hole ERT measurements were obtained and processed with a 2D inversion algorithm to produce images of the subsurface. Results depict a very good correlation between ERT images and the lithology and resistivity logs; an indication of the reliability of the approach.

  • PDF