• Title/Summary/Keyword: Water reuse system

Search Result 186, Processing Time 0.026 seconds

A Study on the Treatment of Wastewater from Ion Removal Process for Purifying Electrocoat Paint in the Bath by Use of Reverse Osmosis (역삼투압을 이용한 전착도료 정제공정폐수처리에 관한 연구)

  • 김진성
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 1998
  • To treat effectively EDIR (electrodeposition ion removal) wastewater in terms of CO$_{Mn}$ 1,500~2,000 ppm generated from aluminum painting process, a RO (reverse osmosis) process was designed and installed to recover and reuse the concentrated solvent sent back to the electrocodeposition tank while the permeate reused as rinse water. A RO system in which three polyamide-spiral wound modules ($102\Phi \times 1,016L$ mm) connnected in series had been running to treat 20 m$^3$ in waste volume in 3 days batch operation at the condition of system recovery of 30 %, applied pressure 11.5 $kg_f/cm^2$ and room temperature. During 42 hours continuous operation leading to 5-fold decrease in waste volume, nearly constant permeation flux of 390 l/m$^2$-hr was maintained and the permeate with average CO$_{Mn}$, 300 ppm was obtained which could be used for washing the remaining paint solution in ion-exchange tower instead of demineralized water. Also COD$_{Mn}$ rejection as a function of running time was observed to be in the range of 78~87 % and the observed solvent rejections for ethyl cellusolve, buthyl cellusolve and n-butanol were 79 %, 87 % and 70 %, respectively.

  • PDF

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF

Evaluation and Improvement Measures on collection and transportation System of Food Waste (음식물 쓰레기 수집운반체계 평가 및 개선 방안)

  • Lee, Hyun-Hee;Ryu, Ji-Young;Shin, Dae-Yewn;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.110-120
    • /
    • 2004
  • This research sought to analyze the food waste collection and transportation system in Korea's related public resource-making facilities, address related problems, and suggest a reasonable alternative measure. For the food waste sorting-out and discharging methods, apartments and similar housings use containers, and individual-style housings use 'quantity-proportional' bags. The sorting and discharging methods should be improved to boost the reuse of resource-made output. The analysis of collection and transportation costs by local governments indicates that they range from 30,000 won to 150,000 won per ton, varying greatly by characteristics of local governments, thus suggesting a need to establish costs calculation criteria to justify the costs. Charges imposed to each household were not greatly problematic in the case of quantity-proportional bags; however, in the case of apartments and similar housings, charges varied greatly, suggesting a need to impose differentiated charges calculated on the basis of collection and transportation costs according to regions. Many places used household-garbage collection vehicles to collect food waste, raising the possibility of causing complaints on leaching water and bad odors. Thus, exclusive food waste collection vehicles should be gradually introduced. Also, in certain places, vehicles should travel more than 20km to collect food waste, and in such cases, a cargo transferring system should be introduced to boost efficiency in carriage.

  • PDF

A Study on Green Library Construction Status and Awareness (녹색도서관 구축 현황 및 인식조사 연구)

  • Hong, Suji;Noh, Younghee
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.25 no.4
    • /
    • pp.79-108
    • /
    • 2014
  • The purpose of this study was to research instances of green library construction and recognition in order to increase awareness of green libraries. To this end, we investigated the green library's outline and green building, evaluated cases of G-SEED certified libraries, and surveyed the employees at the 16 different G-SEED certified libraries. Results showed that the employees' knowledge of green libraries and the green certification system was low, whereas their interest and needs regarding the green library concept were very high. Second, the respondents were able to recognize as a whole the factors of green library construction based on the evaluation items for G-SEED and place particular emphasis on 'recyclable resources & recycling bins.' However, only a few recognized 'water reclamation/reuse system establishment' as a green library factor. Third, the respondents largely agreed upon an evaluation of items on the suitability of G-SEED, and their ranked reasons for build a green library were preventing environmental pollution, energy-saving, environment, ecology, and indoor environmental factors. Fourth, a lack of 'awareness about the concept of the green library' was thought to most affect the awareness of difficulties in green library construction, and the respondents agreed with the need for 'library image enhancement' to better manage expectations of the green library.

A Study on the Assessment of Source-term for PWR Primary System Using MonteCarlo Code (MonteCarlo 코드를 이용한 PWR 일차 계통 선원항 평가에 관한 연구)

  • Song, Jong Soon;Lee, Sang Heon;Shin, Seung Su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.331-337
    • /
    • 2018
  • The decommissioning of nuclear power plants is generally executed in five steps, including preparation, decontamination, cutting/demolition, waste disposal and environmental restoration. So, for efficient decommissioning of nuclear power plants, worker safety, effects compared to cost, minimization of waste, possibility of reuse, etc., shall be considered. Worker safety and measurement technology shall be secured to exert optimal efficiency of nuclear power plant decommissioning work, for which accurate measurement technology for systems and devices is necessary. Typical In-Situ methods for decommissioning of nuclear plants are CZT, Gamma Camera and ISOCS. This study used ISOCS, which can be applied during the decommissioning of a nuclear power plant site without collecting representative samples, to take measurements of the S/G Water Chamber. To validate the measurement values, Microshield and the GEANT4 code was used as the actual method were used for modeling, respectively. The comparison showed a difference of $1.0{\times}10^1Bq$, which indicates that it will be possible to reduce errors due to the influence of radiation in the natural environment and the precision of modeling. Based on the research results of this paper, accuracy and reliability of measurement values will be analyzed and the applicability of the direct measurement method during the decommissioning of NPPs will be assessed.

A basic study on development of high-pressure compact steam unit applied hybrid heat exchanger (하이브리드 열교환기 적용 고압 컴팩트 스팀 유닛 개발에 관한 기초 연구)

  • Kim, Jeung-Hoon;Lim, Gye-Hun;Kim, Seung-Hyun;Jin, Chul-Kyu;Park, Jae-Hong;Cho, Sung-Youl;Hong, In-Ki;Lee, Sang-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.453-457
    • /
    • 2016
  • In various industrial plants such as power generation plants, petrochemical plants, and unit factories, there is an increasing demand for a system that generates hot water using waste or surplus steam. Compact steam unit (CSU), which produces hot water by using steam, is a good solution considering energy reuse. In this study, as a basic study to develop a high-pressure CSU, heat transfer characteristics of a hybrid heat exchanger were investigated through experiments, in order to use the hybrid heat exchanger instead of a conventional plate heat exchanger as the core component of CSU. The experimental results are the followings. Heat balance between the hot side and cold side was satisfied within ${\pm}5%$. Overall heat transfer coefficient increased linearly as the Reynolds number increased and exceeded $5,524W/m^2K$ when the flow velocity was above 0.5 m/s. In addition, pressure drop also increased as the Reynolds number increased, and pressure drop per unit length was below 50 kPa/m.

Development of a reuse system for agricultural purpose with wastewater in Youljung, Jeju Island (제주 월정 농업용수재이용시스템 개발)

  • Lee, Kwang-Ya;Kim, Hae-Do;Joo, Jin-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.470-470
    • /
    • 2011
  • 환경부 하수재이용사업은 2007년도 하수도법 개정을 통해 공공하수처리시설 처리수의 재이용 의무화를 시작으로 2010년도 "물의 재이용 촉진 및 지원에 관한 법률"의 시행으로 전국적으로 사업이 확대되고 있다. 제주도 월정하수처리장은 2009년도 하수재이용사업지구로 선정이 되어 2010년도부터 농업용목적의 재이용으로 구체적인 설계와 시공이 추진되고 있는 사업지구이다. 제주도에서는 지하수보존을 위해 대체수자원 개발 방안을 시급히 마련중에 있다. 특히, 제주도 농업용수 종합계획수립(제주도, 2004)에는 하수처리수를 농업용수로 이용하기 위한 계획을 수립할 정도로 지하수 사용량을 줄이기 위한 노력을 진행중에 있으며, 그 일환으로 하수재이용사업을 지속적으로 추진하고 있다. 하수처리수의 농업용수 재이용은 사용된 물을 재이용함으로써 물과 에너지를 절약할 수 있고, 유역 또는 해양으로 배출되는 오염원을 억제하는 장점이 있는 반면에 농산물 생육에 직접 영향을 줄뿐만 아니라 주변의 수질 생태 토양 환경 및 영농인의 보건에도 영향을 주기 때문에 장기적인 관찰과 검증작업이 필요하다. 이 에 서울대와 한국농어촌공사는 안전한 농업용수 재이용기술을 개발하기 위해 장기간 현장시험을 통해 재이용 재배기술과 함께 보건환경에 미치는 영향을 검증하였고 그 개발기술을 월정사업지구에 적용하게 되었다. 월정하수처리장이 위치한 제주 동부의 월정지역은 농지면적이 밭(374ha)과 과수(12ha)등 제주도의 전형적인 농촌마을으로 주요 재배작물은 마늘과 당근, 쪽파, 콩 등으로서 농업기반시설의 미비로 영농에 어려움을 호소하고 있으며, 2006년도에 발생한 가뭄으로 그 해 평균 수학량의 30%가 감소된 바 있는 지역이다. 제주도 농업용수 종합계획수립(2004, 제주도)에서는 10년에 한발을 기준 으로 $43,000m^3$/일의 용수가 부족할 것으로 분석하였으며 최근 $35,000m^3$/day 규모의 상수도 확보사업 계획 수립하였으나 여전히 농업용수가 부족하다. 방류수의 수질은 방류수수질기준을 만족하지만 염분함량이 높아 직접 농업용으로 사용하기에는 적당하기 않고, 농업용재이용방류수 수질기준에 맞도록 재이용시스템을 통해 재처리하여 농업용수로 사용해야 한다. 제주도에서는 이미 제주 서부하수처리장 농업용수 재이용사업(이하 판포재이용사업)'이 완료되어 재이용수를 농업용수로 공급하고 있으며 향후 지속적으로 하수재이용사업이 확대될 것으로 판단된다.

  • PDF

Application in Membrane Hybrid System with Acrylic Wastewater Pretreated by $TiO_2$ ($TiO_2$로 전처리한 아크릴 폐수의 Membrane Hybrid System에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek;Lee, Gang-Choon
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.183-188
    • /
    • 2009
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with $TiO_2$, it was utilized in MF/UF/RO process. After composing of ultrafiltration/reverse osmosis or microfiltration/reverseosmosiss module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. The permeate of ultrafiltration or microfiltration module was sent to reverse osmosis module. It was found that final permeate flux of reverse osmosis module in module set 2 (MWCO 200,000 UF+RO) was excellent. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in UF and MF modules. From the above result, the removal efficiency of TDS, T-N and COD was very excellent in RO module. The removal efficiency of turbidity in UF and MF module was very high (> 99% removal efficiency). Final water quality of acrylic wastewater treated by the membrane module set was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Recovery of phosphoric acid from the waste acids in semiconductor manufacturing process (반도체 제조공정에서 발생하는 혼산폐액으로부터 고순도 인산 회수)

  • Park, Sung-Kook;Roh, Yu-Mi;Lee, Sang-Gil;Kim, Ju-Yup;Shin, Chang-Hoon;Ahn, Jae-Woo
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2006.05a
    • /
    • pp.90-94
    • /
    • 2006
  • The waste solution discharged from the LCD manufacturing process contains acids like nitric, acetic and phosphoric acid and metal ions such as Al, Mo and other impurities. It is important to removal of impurities to tess than 1ppm in phosphoric acid to reuse as an etchant because the residual impurities even in sub-ppm concentration in semiconductor materials play a major role on the electronic properties. In this study, we have been clearly established that a mixed system of solvent extraction, diffusion dialysis and ion-exchange technique, which made individually the most of characteristics is developed to commercialize in an efficient system for recovering the high-purity phosphoric acid. By applying vacuum evaporation, the yield of the process are almost 99% removal of nitric acid and acetic acid was achieved. And by applying the solvent extraction method with tri-octyl phosphate(TOP) as an extractant, the removal of acetic and nitric acid from the acid mixture was achieved effectively at the ratio O/A=1/3 with four stages and the stripping of nitric acid from organic phase is attained at a ration of O/A=1 with six stages by distilled water. About 97% and 76% removal of Al and Mo were achieved by diffusion dialysis. Essentially complete less than 1ppm removal of Al, Mo by using ion exchange ion resin and purification of the phosphoric acid was obtain.

  • PDF

Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture (생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발)

  • LEE Ki-Wan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.4
    • /
    • pp.380-391
    • /
    • 1993
  • The experimental study was made to propose the treatment method of wastewater in the high-density fish culture system. The BOD to COD ratios of effluents were almost same to 0.65 in the eel-farm, but were various in the farm rearing together with tilapia etc. A BOD rate curve of the eel-farm effluent could be described mathematically by the equation, $BODu=14.1(1-10^{-0.222t})+30.9(1-10^{-0.035(t-8)})$. Nitrification in Biological Fluidized Bed(BFB) system to treat the fish-farm wastewater could be reduce ammonium level up to $65{\sim}79\%$ when ammonium loading rates were between 0.014 and 0.075g $NH_4/g$ BVS-day. Nitrification efficiency was decreased by organic matters in the wastewater when ammonium loading was low(0.014 g $NH_4/g$ BVS-day). T-N removal ratios were decreased to increase loading in denitrification process, because of low C/N ratio. Based on much higher biological mass concentrations, BFB system takes many advantages of a practical viewpoint, such as stability of treatment efficiency and reduction of necessary site area for the facility, as compared with conventional treatment systems.

  • PDF