• Title/Summary/Keyword: Water reuse system

Search Result 186, Processing Time 0.032 seconds

Rice Growth Response and Soil Quality by Domestic Wastewater Irrigation on Rice Paddy Field - Lysimeter experiment - (하수종말처리장 방류수를 논 관개용수로 처리시 벼 생육 및 토양환경 영향 조사 - 라이시미터 재배실험 -)

  • Cho, Jae-Young;Park, Seung-Woo;Son, Jae-Gwon;Park, Bong-Ju;Li, Long-Gen
    • Journal of Korean Society of Rural Planning
    • /
    • v.12 no.2 s.31
    • /
    • pp.49-56
    • /
    • 2006
  • The application of domestic wastewater on rice paddies results in the accumulation of sodium(Na$^+$) to the soil. Excessive concentration of sodium may cause the deterioration of the physical characteristics of the soil, change in the osmosis of the soil, destruction of soil aggregates as well as ion toxicity due to sodium accumulation. Using domestic wastewater as irrigation water should be preceded by measures to prevent or control the soil salinization caused by sodium. Agricultural reuse of domestic wastewater were found not to cause serious problems with food safety due to heavy metals. However, pre-treatment using ultraviolet or ozone is recommended to reduce the number of bacteria and gem and for public health reasons. Using domestic wastewater has shown that reducing the standard application of chemical fertilizers by as much as 50% reduced the harvesting index by only 10%. This study has shown that it is feasible to reuse domestic wastewater on rice paddies. In order to facilitate the application, it is deemed necessary to establish wastewater treatment technologies in the future, to review criteria for recycling domestic wastewater for agricultural purposes such as conditions of soil and cropping system and to resolve conflicts with farmers and public health issues.

Changes and Influences of Stream Water Quantity due to Urbanization: Focusing on Urban Streams in Gyeonggi-do (도시화에 따른 하천수량 변화 및 영향_경기도 도심하천을 중심으로)

  • Noh, Huiseong;Jo, Dongho;Kim, Yonsoo;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.19 no.4
    • /
    • pp.491-500
    • /
    • 2017
  • Stream water quantity is the most basic, fundamental and important element for stream water quality and for conservation of ecological environment. This study aims to analyze causes of changes in stream water quantity based on the percentage of impervious surface area (%ISA) in urban streams of Gyeonggi-do, and also to present a method to secure water quantity of urban streams in Gyeonggi-do and data to be applied to River Management Policy. For this purpose, the Anyangcheon watershed, the Tancheon watershed, and the Osancheon watershed were selected as samples of the urban streams. In addition, the stream water quantity and the changes in stream water quality which were based on the amount of ISA, and methods to directly and indirectly secure stream water quantity were investigated. The results are as follows. The amounts of ISA of the Anyangcheon watershed, of the Tancheon watershed, and of the Osancheon watershed showed a 5.32%, 6.32%, and 7.22% increase, respectively, from 2014 which was approximately 10 years ago. The runoff coefficient generally increased as the amount of ISA was increased. Water reuse quantity of stream in the Tanchon watershed had a positive effect on securing stream water quantity, but both in the Anyangcheon watershed and in the Osancheon watershed, it did not have a positive effect on that. However, water reuse quantity of stream improved the water quality of each stream.

Reusability of Surfactant-coated Candida rugosa Lipase Immobilized in Gelatin Microemulsion-based Organogels for Ethyl Isovalerate Synthesis

  • Dandavate, Vrushali;Madamwar, Datta
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.735-741
    • /
    • 2008
  • In our previous study, a surfactant-coated Candida rugosa lipase immobilized in microemulsion-based organogels was exploited for the synthesis of ethyl isovalerate. In the present study, we are focusing on the effective reuse of lipase immobilized in microemulsion-based organogels (MBGs) in terms of retainment of the catalytic activity. As water is one of the co-products in esterification reactions, the removal of water becomes a priority to allow the reaction to work in the forward direction and to prevent back hydrolysis. Taking this fact into consideration, the lipase-containing microemulsion-based organogels were given pretreatment and/or several intermittent treatments with dry reverse micellar solution of AOT in organic solvent during repeated cycles of ester synthesis. The pretreated MBGs with dry reverse micellar solution exhibited lower water content and higher initial rates of esterification in comparison with untreated freshly prepared MBGs. The esterification efficiency of untreated MBGs started decreasing after 5 cycles of reuse and was almost completely lost by the end of the $8^{th}$ cycle. In contrast, pretreated MBGs exhibited a gradual decrease in esterification efficiency after 5 cycles and retained about 80% of the initial activity at the end of the $8^{th}$ cycle. The intermittent treatment of MBGs after every 3 cycles resulted in enhanced reusability of immobilized lipase for up to 9 cycles without significant loss in esterification activity, after which it resulted in a slow decrease in activity with about 27% lower activity at the end of the $12^{th}$ cycle. Furthermore, the treatment conditions such as concentration of AOT in liquid dessicant and time of treatment were optimized with respect to our system. The granulated MBGs proved to be better in terms of initial esterification rates (1.2-fold) as compared with the pelleted MBGs.

Characteristics of dissolved gases separated from water mixed with exhalation gases without using a compressor

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.10
    • /
    • pp.916-921
    • /
    • 2016
  • It is possible for humans to breathe underwater using dissolved oxygen. However, unlike fish, humans need large amounts of oxygen to breathe underwater. Water generally contains small amounts of dissolved oxygen. To get enough dissolved oxygen from water, great volumes of it should be supplied into a separation device. If exhalation gases are used, the amounts of water supplied into the membrane can be decreased. However, the characteristics of exhalation gases after passage through the separation device need to be investigated. To reuse the exhalation gases, the concentration of carbon dioxide should be decreased. A compressor is needed to supply the exhalation gases because of the high pressure generated in the membrane inlet. However, compressors require a lot of power and are heavy, so it is not proper to get the portable separation device. A system without the compressor is needed. If the pressure of the position mixed from the exhalation is less than atmosphere, the compressor is not needed. In this thesis, characteristics of the gases which are mixed with exhalation gases and separated from water after passing the membrane are investigated. The compositions of carbon dioxide, oxygen, and nitrogen are measured with the gas chromatography. The effects of water and exhalation gas flow rates on characteristics of gases separated from water after the membrane are showed.

The BNR-MBR(Biological Nutrient Removal-Membrane Bioreactor) for nutrient removal from high-rise building in hot climate region

  • Ratanatamskul, C.;Glingeysorn, N.;Yamamoto, K.
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.133-140
    • /
    • 2012
  • The overall performance of BNR-MBR, so-called Anoxic-Anaerobic-Aerobic Membrane Bioreactor ($A^3$-MBR), developed for nutrient removal was studied to determine the efficiencies and mechanisms under different solid retention time (SRT). The reactor was fed by synthetic high-rise building wastewater with a COD:N:P ratio of 100:10:2.5. The results showed that TKN, TN and phosphorus removal by the system was higher than 95%, 93% and 80%, respectively. Nitrogen removal in the system was related to the simultaneous nitrification-denitrification (SND) reaction which removed all nitrogen forms in aerobic condition. SND reaction in the system occurred because of the large floc size formation. Phosphorus removal in the system related to the high phosphorus content in bacterial cells and the little effects of nitrate nitrogen on phosphorus release in the anaerobic condition. Therefore, high quality of treated effluent could be achieved with the $A^3$-MBR system for various water reuse purposes.

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

A Comparative Study Between High and Low Infiltration Soils as Filter Media in Low Impact Development Structures

  • Guerra, Heidi B.;Geronimo, Franz Kevin;Reyes, Nash Jett;Jeon, Minsu;Choi, Hyeseon;Kim, Youngchul;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.130-130
    • /
    • 2021
  • The increasing effect of urbanization has been more apparent through flooding and downstream water quality especially from heavy rainfalls. In response, stormwater runoff management solutions have focused on runoff volume reduction and treatment through infiltration. However, there are areas with low infiltration soils or are experiencing more dry days and even drought. In this study, a lab-scale infiltration system was used to compare the applicability of two types of soil as base layer in gravel-filled infiltration systems with emphasis on runoff capture and suspended solids removal. The two types of soils used were sandy soil representing a high infiltration system and clayey soil representing a low infiltration system. Findings showed that infiltration rates increased with the water depth above the gravel-soil interface indicating that the available depth for water storage affects this parameter. Runoff capture in the high infiltration system is more affected by rainfall depth and inflow rates as compared to that in the low infiltration system. Based on runoff capture and pollutant removal analysis, a media depth of at least 0.4 m for high infiltration systems and 1 m for low infiltration systems is required to capture and treat a 10-mm rainfall in Korea. A maximum infiltration rate of 200 mm/h was also found to be ideal to provide enough retention time for pollutant removal. Moreover, it was revealed that low infiltration systems are more susceptible to horizontal flows and that the length of the structure may be more critical that the depth in this condition.

  • PDF

Reuse and Remediation of Closed Landfill in Korea

  • Shin, Chan-ki
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.91-99
    • /
    • 2002
  • A recent survey investigated that there were over one thousand un-controlled closed landfills(1,072 sites) in Republic of Korea. Most of these landfills were constructed before 1986. Waste management act were not promulgated at that time, so they usually do not have dranage system and leachate treatment facility. Also, considerable attention has been received to landfill leachate pollution, leachate has an adverse impact on the surrounding environment such as soil, groundwater, and water supply source. According to the result of survey for closed landfill management, it was reported that 875 sites out of 1,072sites(81.6%) have no leachate treatment facility and 630 sites out of 1,072sites(58.7%) have been used for farm lands and residence. Consequently it is hard to do postclosure care continuously in most of cases and these uncontrolled landfills have contaminated farm lands and residence. The average age of these landfills are ranged mostly between 2 to 15 years. Much time and advanced technology are needed to remediate these uncontrolled landfills, therefore the survey for present status of closed landfill sites is required and suitable treatment processes should be prepared. With this point of view, We has been investigated to find out the present status of closed landfill, problems of post management and discussed plans for remediation and reuse. Remedial actions of un-controlled landfill have been carried out the many cities since 1997 upto now. Most frequently applied technology were reuse after excavation and there were several cases to capping in the surface of landfill and to construct subsurface barriers. It is considered that landfills in use have a possibility not to be controlled because of inadequate construction and improper management. Therefore remediation of uncontrolled landfills and recovery technology should be develop continuously Especially, it has been expected that resource technology of landfill gas as a energy has some advantages in controlling odors in the site area and accelerating stabilization of landfills with the energy.

  • PDF

Evaluation of operating performance of secondary effluents treatment membrane system adapted chemical backwashing (약품역세를 적용한 하수재이용 막여과 시스템의 운전성능 평가)

  • Kim, Young-Hoon;Lee, Chang-Ha;Jeon, Min-Jung;Lee, Yong-Soo;Lee, Eui-Jong;Nam, Jong-Woo;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.335-342
    • /
    • 2011
  • Secondary effluent contains particle compounds which are comprised of microorganisms that occurs membrane fouling when the water is reused. This study evaluates the characteristics of membrane fouling of secondary effluent reuse. Effects of chemical backwashing are analyzed to reduce membrane fouling by regular chemical backwashing. As the result, major membrane foulants are verified EPS materials which include protein and polysaccharide that cause biofilm cake layer on the membrane. Also, sodium hypochlorite is applied to chemical backwashing. The backwashing improves recover rate when injected chemical concentration is increased and chemical backwashing cycle is amplified. Chemical backwashing cycle affects more than injected chemical concentration yet idle time does not noticeably influence on reducing membrane fouling.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF