• 제목/요약/키워드: Water resistance.

검색결과 3,386건 처리시간 0.032초

농산물 저온유통용 내수 골판지 상자의 제조(제2보) - 골판지의 내수 및 내습성 향상을 위한 약품 적용 방법 - (Manufacture of Water-Resistant Corrugated Board Boxes for Agricultural Products in the Cold Chain System(II) - Application Methods of Chemicals for Improving Water and Moisture Resistance of Corrugated Boards -)

  • 조중연;민춘기;신준섭
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2004년도 춘계학술발표논문집
    • /
    • pp.192-210
    • /
    • 2004
  • Application methods of chemicals were investigated tn minimize strength reduction of corrugated boards under the high humidity environment encountered in the cold chain system. Starch insolubilizers were introduced in the starch solution preparation of the Stain hall method and their insolubilization effect of starch binder were estimated. The performance of water repellent agents(WRA) and moisture proof agents(MPA) were evaluated in terms of water and moisture resistance. And effects of the combination of the chemicals and the coating method were also examined. Addition of the polyamine polyamide insolubilizer to the main part in the Stain hall process improved the binding force and water resistance of starch, which contributed to minimize the strength reduction of paper under the high humidity environment. AZC and Glyoxal type insolubilizers could not be used in the experiment due to an excessively increased viscosity of starch solution and the poor stability. Conventional WRA treatment to the base paper enhanced water and moisture resistance very slightly even though water repellency of the paper reached R10 by the treatment. MPA showed excellent performance than WRA not only in water and moisture resistance but in water repellency. Double coating on paper with MPA was more effective than the single coating at the same coating weight. A newly developed MPA showed excellent performance and runnability only by a single coating instead of a double coating.

  • PDF

농산물 저온유통용 내수 골판지 상자의 제조(제2보) - 골판지의 내수 및 내습성 향상을 위한 약품 적용 방법 - (Manufacture of Water-Resistant Corrugated Board Boxes for Agricultural Products in the Cold Chain System(II). -Application Methods of Chemicals for Improving Water and Moisture Resistance of Corrugated Boards-)

  • 조중연;민춘기;신준섭
    • 펄프종이기술
    • /
    • 제36권2호
    • /
    • pp.60-69
    • /
    • 2004
  • Application methods of chemicals were investigated to minimize strength reduction of corrugated boards under the high humidity environment encountered in the cold chain system. Starch insolubilizers were introduced in the starch solution preparation of the Stein hall method and their insolubilization effect of starch binder were estimated. The performance of water repellent agents(WRA) and moisture proof agents(MPA) were evaluated in terms of water and moisture resistance. And effects of the combination of the chemicals and the coating method were also examined. Addition of the polyamine polyamide insolubilizer to the main part in the Stein hall process improved the binding force and water resistance of starch, which contributed to minimize the strength reduction of paper under the high humidity environment. AZC and Glyoxal type insolubilizers could not be used in the experiment due to an excessively increased viscosity of starch solution and the poor stability. Conventional WRA treatment to the base paper enhanced water and moisture resistance very slightly even though water repellency of the paper reached R10 by the treatment. MPA showed excellent performance than WRA not only in water and moisture resistance but in water repellency. Double coating on paper with MPA was more effective than the single coating at the same coating weight. A newly developed MPA showed excellent performance and runnability only by a single coating instead of a double coating.

수용성 유황 첨가 콘크리트의 역학 특성 및 탄산화 저항성 (Mechanical Properties and Carbonation Resistance of Water-Soluble Sulfur Concrete)

  • 홍기남;지세영;박재규;정규산;한상훈
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.103-109
    • /
    • 2014
  • In this study, two types of water-soluble sulfur, LSA and LSB, were developed and the influence of the water-soluble sulfur on the mechanical properties and durability of concrete were experimentally evaluated. In order to evaluate mechanical properties and carbonation resistance of concrete with water-soluble sulfur, compressive strength test, flexural strength test, bonding strength test, and carbonation resistance test were performed. Compressive strength of only concrete with 1% LSA was increased while that of concrete with LSB was proportionally increased with the higher LSB dosage. On the other hand, flexural strength of concrete with LSA and LSB was increased by 12-41% and 36-74%, respectively. Carbonation resistance of concrete with water-soluble sulfur were increased by 25-66%. As a result, it should be noted that the water-soluble sulfur can not only solve the demerit of sulfur concrete but also offer the durability of sulfur concrete.

막여과 정수처리 공정에서 온도보정차압 식의 파울링 지표로서의 활용성 검토 (Applicability of Temperature Correction Trans-membrane Pressure as a Fouling Index of Membrane Water Treatment Process)

  • 김민재;임재림;이경혁;이영주;김수한
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.1-8
    • /
    • 2016
  • Temperature correction trans-membrane pressure (TC-TMP) is frequently used as a fouling index in membrane water treatment plants. TC-TMP equation is derived based on an assumption that the total membrane resistance (i.e. the sum of the intrinsic membrane resistance and fouling resistance) is not affected by temperature. This work verified the validity of this assumption using microfiltration (MF) and ultrafiltration (UF) membranes with and without fouling. The foulants used in the work were kaolin (inorganic) and humic acid (organic). The intrinsic resistances of MF and UF membranes remains at constant values regardless of temperature change. When the same amount of foulants were accumulated on the membrane, inorganic fouling resistance with kaolin was constant regardless of temperature change while organic fouling resistance with humic acid decreased at higher temperatures, which means that TC-TMP cannot be used as a fouling index when organic fouling occurs in a real field application. Since TC-TMP underestimates the amount of fouling at higher temperatures, more attention should be necessary in the operation of membrane water treatment plant in a hotter season like summer.

세라믹 막여과 정수처리 공정에서 유입수질 및 막여과유속이 막오염 형성에 미치는 영향 (Effects of membrane fouling formation by feed water quality and membrane flux in water treatment process using ceramic membrane)

  • 강준석;박서경;이정준;김한승
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.77-87
    • /
    • 2018
  • In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than $5m^3/m^2{\cdot}day$. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.

Study of Cresol-Novolac Epoxy Systems on Fusion Bonded Epoxy Coatings for Pipeline Protection

  • Chung, Chi Wook;Lee, Sang Sun;Chai, Soo Gyum;Lim, Jong Chan
    • Corrosion Science and Technology
    • /
    • 제2권4호
    • /
    • pp.202-206
    • /
    • 2003
  • Fusion Bonded Epoxy(FBE) systems have been widely used to protect pipelines for over 30 years. Numerous attempts have so far been made to improve the properties of FBE coatings such as chemical resistance, adhesion, water resistance, cathodic disbondment resistance, impact resistance, and flexibility to protect pipelines at a wet and a high temperature condition. But these attempts have not been successful in reducing some weakness, for instance, in pipeline operating at high temperature due to poor hot water resistance and cathodic protection. The purpose here is to build a basis for getting better corrosion resistance of FBE systems. Cresol-novolac epoxy coating systems were studied compared to bisphenol A type epoxy systems. After the immersion of the film in water at a high temperature for a long period, good adhesion to metal substrate and excellent cathodic disbond resistance were observed in the cresol-novolac epoxy resin systems. It is well known that the adhesion of organic coatings to metal substrate might be decreased due to the disruption of a chemical bond across the film and metal interface induced by water molecules. A high crosslinking density might decrease water permeability and improve cathodic disbonding protection in the coatings. Other factors are studied to understand anti-corrosion mechanism of Cresol-novolac epoxy coatings. In addition, the water absorption rate and the effect of cure temperature on the adhesion and cathodic disbonding resistance ofthe films were studied in different epoxy coatings and the effect of substrate was evaluated. The results of field application are proved that the Cresol-novolac epoxy coating system developed recently is one of the most suitable coatings for protection of pipelines.

Bow hull-form optimization in waves of a 66,000 DWT bulk carrier

  • Yu, Jin-Won;Lee, Cheol-Min;Lee, Inwon;Choi, Jung-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.499-508
    • /
    • 2017
  • This paper uses optimization techniques to obtain bow hull form of a 66,000 DWT bulk carrier in calm water and in waves. Parametric modification functions of SAC and section shape of DLWL are used for hull form variation. Multi-objective functions are applied to minimize the wave-making resistance in calm water and added resistance in regular head wave of ${\lambda}/L=0.5$. WAVIS version 1.3 is used to obtain wave-making resistance. The modified Fujii and Takahashi's formula is applied to obtain the added resistance in short wave. The PSO algorithm is employed for the optimization technique. The resistance and motion characteristics in calm water and regular and irregular head waves of the three hull forms are compared. It has been shown that the optimal brings 13.2% reduction in the wave-making resistance and 13.8% reduction in the added resistance at ${\lambda}/L=0.5$; and the mean added resistance reduces by 9.5% at sea state 5.

Characterization of Extended Spectrum Beta-Lactamases (ESBL) Producing Escherichia coli Isolates from Surface Water Adjacent to Pharmaceutical Industries in Bangladesh: Antimicrobial Resistance and Virulence Pattern

  • Taslin Jahan Mou;Nasrin Akter Nupur;Farhana Haque;Md Fokhrul Islam;Md. Shahedur Rahman;Md. Amdadul Huq;Anowar Khasru Parvez
    • 한국미생물·생명공학회지
    • /
    • 제51권3호
    • /
    • pp.268-279
    • /
    • 2023
  • The pharmaceutical industry in Bangladesh produces a diverse range of antibiotics for human and animal use, however, waste disposal management is inadequate. This results in substantial quantities of antibiotics being discharged into water bodies, which provide suitable environment for the growth of antibiotic-resistant bacteria, capable of spreading resistance genes. This study intended for exploring the bacterial antibiotic resistance profile in adjoining aquatic environmental sources of pharmaceutical manufacturing facilities in Bangladesh. Seven surface water samples were collected from the vicinity of two pharmaceutical industries located in the Savar area and 51 Escherichia coli isolates were identified using both phenotypic and genotypic methods. Antibiotic susceptibility tests revealed the highest percentage of resistance against ampicillin, azithromycin, and nalidixic acid (100%) and the lowest resistance against meropenem (1.96%) out of sixteen different antibiotics tested. 100% of the study E. coli isolates were observed with Multidrug resistance phenotypes, with the Multiple Antibiotic Resistance (MAR) value ranging from 0.6-1.0. Furthermore, 69% of the isolates were Extended Spectrum Beta-Lactamases (ESBL) positive as per the Double Disk Diffusion Synergy Test (DDST). ESBL resistance genes blaTEM, blaCTX-M-13, blaCTX-M-15, and blaSHV were detected in 70.6% (n = 36), 60.8% (n = 32), 54.9% (n = 28), and 1.96% (n = 1) of the isolates, respectively, by Polymerase Chain Reaction (PCR). Additionally, 15.68% (n = 8) of the isolates were positive for E. coli specific virulence genes in PCR. These findings suggest that pharmaceutical wastewater, if not properly treated, could be a formidable source of antibiotic resistance spread in the surrounding aquatic environment. Therefore, continued surveillance for drug resistance among bacterial populations around drug manufacturing facilities in Bangladesh is necessary, along with proper waste disposal management.

겨울용 쾌적 보온성 의복의 온열특성에 관한 연구 - 무풍환경하에서 - (A Study on the Thermal Characteristics of Comfortable Heat-Retaining Winter Clothing)

  • 송민규;권명숙
    • 복식
    • /
    • 제58권6호
    • /
    • pp.24-34
    • /
    • 2008
  • The purpose of this study was to create a database of information on fabric factors(i.e., fabric insulation, fabric weight, clothing weight, fabric thickness, air permeability, and water vapor resistance) of clothing used for insulations, to compare them according to clothing types, and to estimate thermal resistance of clothing using these factors. A total of 25 kinds of clothing were selected(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal insulation of clothing showed the highest positive correlation(0.85, p>0.01) with thermal insulation of fabric and very high positive correlation with water vapor resistance, fabric thickness, fabric weight, and clothing weight, respectively, 0.77, 0.77, 0.73, 0.71(p>0.01). Fabric weight of jacket was higher than that of shirts and trousers. Air permeability of shirts was the highest of clothing types. Clothing insulation of jacket was higher than that of shirts and trousers and its fabric insulation was also the highest of clothing types. Regression analysis showed that fabric thickness, water vapor resistance, and fabric weight would be useful factors for estimating the thermal resistance of clothing.

전기화학적 부동태화에 의한 동관의 내식성 개선 연구 (Improvement of Corrosion Resistance for Copper Tube by Electrochemical Passivation)

  • 민성기;김경태;황운석
    • Corrosion Science and Technology
    • /
    • 제10권4호
    • /
    • pp.125-130
    • /
    • 2011
  • This study was performed to improve the corrosion resistance and the stability of passive film on copper tube by potentiostatic polarization method in synthetic tap water. Formation of passive film was carried out by anodic potentiostatic polarization at various passivation potentials and passivation times in 0.1 M NaOH solution. Stability of passive film and corrosion resistance was evaluated by self-activation time, ${\tau}_0$ from passive state to active state on open-circuit state in 0.1 M NaOH solution. Addition of polyphosphate in NaOH solution prolonged the self-activation time and improved the corrosion resistance, and the addition of 5 ppm polyphosphate was most effective. It was also observed that better corrosion resistance was obtained by potentiostatic polarization at 1.0 V (vs. SCE) than at any other passivation potentials. Passivated copper tube showed perfect corrosion resistance for the immersion test in synthetic tap water showing that the anodic potentiostatic polarization treatment in 0.1 M NaOH with 5 ppm polyphosphate solution would be effective in improving the corrosion resistance and preventing the blue water problem.