• Title/Summary/Keyword: Water quality comparison

Search Result 664, Processing Time 0.036 seconds

Comparison of the Quality of Frozen Skipjack Tuna Katsuwonus pelamis Thawed by Vacuum and Water Immersion (진공 해동과 침수 해동에 의한 냉동 가다랑어(Katsuwonus pelamis)의 품질 차이에 관한 연구)

  • Lee, Tae-Hun;Koo, Jae-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.6
    • /
    • pp.635-639
    • /
    • 2012
  • Thawing is very important in tuna canning because it affects the yield and quality of the canned tuna, and productivity. The effects of vacuum thawing on the quality, yield, and thawing times of frozen skipjack were compared with conventional water immersion thawing. The time required to thaw frozen skipjack tuna (weight 2.5-3.0 kg) from $-10^{\circ}C$ to $-2^{\circ}C$ was 75, 60, and 37 min at a pressure of 17, 23, and 31 mmHg, respectively, corresponding to temperatures of 20, 25, and $30^{\circ}C$. The thawing time decreased with increasing pressure. Vacuum thawing shorten the thawing time by 58-80% compared with water immersion thawing at $20^{\circ}C$, and there was less difference between the core and skin temperatures than with water immersion thawing. No significant change in pH or histamine was observed according to thawing method, while the volatile basic nitrogen (VBN), trimethylamine (TMA), and K value were lower with vacuum thawing than water immersion thawing. Based on these results, we believe that vacuum thawing minimizes the biochemical and microbial changes that occur while thawing frozen skipjack tuna.

Development of Method for Deciding Automatically Parameters of Water Quality Simulation Models (수질모형의 매개변수 자동보정 프로그램 개발에 관한 연구)

  • Song, Kwang-Duck;Paik, Do Hyeon;Lee, Yong Woon
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2006
  • Water quality simulation models include the difference between the measured and estimated values as an inevitable consequence because they represent the complicated natural phenomena as simplified mathematical equations. The major reason of the difference occurrence is due to the use of the imprecise values of the model parameters, but the parameter values are currently determined by the try and error method directly performed by humans. However, the use of this method requires many time and endeavor of humans, and generally does not obtain the most suitable parameter values. A method for deciding model parameter values is, therefore, developed in this study. The method minimizes the difference between the measured and estimated values and also distributes uniformly the measured values on the upper and lower sides of the line representing the estimated values. A user interface based on this method is also developed by using the Visual Basic 6.0 of Microsoft, and it can be operated in the environment of Windows 98/2000. In this study, the method for deciding model parameter values is applied for estimating the water quality of the stream Ko-heung. The results of the application show that the method, including its computer program, can effectively obtain the most suitable parameter values and also save many working time in comparison with the existing method directly performed by humans.

The Comparision of the Characteristics of Water Quality in Alternative Aerobic-Anoxic and Aerobic Sludge Digestion (선택적인 Aerobic-Anoxic과 Aerobic 슬러지소화에서의 수질특성 비교)

  • Lim, Bong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.74-80
    • /
    • 1997
  • The objectives of this study were to compare the characteristics of water quality in alternative Aerobic-Anoxic(A/A) and Aerobic(Control) sludge digestion. The A/A process control parameter as the pH signal(dpH/dt) was used. Comparison of the result of A/A digestion with those of Aerobic digestion indicated a 54% saving in aeration compared to Aerobic digestion. TN removal efficiency rates of A/A and Aerobic digestion were 45% and 4%, respectively. The concentration of COD(64 mg/l and 268 mg/l for the A/A and Aerobic digestion, respectively) and Ortho-P in the supernatant were also less with A/A digestion. MLVSS and Coliform destructions were noticed similar for both digestion, but better dewatering charateristics were noted for the A/A digestion.

  • PDF

Performance Evaluation of Water Vapour Adsorption/Desorption Property for a Building Material by Mock up Test (실물시험을 통한 흡방습 건축자재의 성능평가)

  • Kim, Hea Jeong;Song, Kyoo Dong;Lee, Yun Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.53-58
    • /
    • 2009
  • There are increasing developments and uses of functional building materials are recently developed and introduced to the test method for the materials. Especially, moisture problem has a major role are also being established in indoor air quality problems. The purpose of this study is to evaluate the water vapour adsorption/desorption property of a ceiling material. The variation of the temperature and moisture were measured with the application materials by mock up test based on JIS 1470-1. The result shows that water vapour adsorption/desorption property of ceiling material is appeared in changes of moisture adsorption and desorption in comparison with that of a general ceiling material. Therefore, in case of decreasing and increasing in humidity, these materials can be used as an finishing material to sustain comfort condition.

Comparison of Water Quality Models for Prediction of Nutrients in Lake Paldang (팔당호의 영양염류 예측을 위한 수질관리모형의 비교)

  • Park, Kyung-Chul;Ahn, Kyu-Hong;Yeon, Ick-Tae;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.2
    • /
    • pp.174-180
    • /
    • 2000
  • In this study two water quality models, widely used in Korea, WASP5 and SWRRB were applied to Lake Paldang. The simulated results were compared with the measured data. The simulation results using WASP5 showed that this model could reasonably predict the concentrations of $NO_3$-N, Organic N, and Organic P. In order to investigate the effect of pollution by non-point source SWRRB was simulated and the concentrations of nutrients were predicted. The results from WASP5 and SWRRB are not directly comparable because their input data are different and output values are differently presented. Therefore, if these two simulation models were applied simultaneously, many valuable data and information could be obtained due to their own applicabilities and advantages.

  • PDF

CALIBRATION AND VALIDATION OF THE HSPF MODEL ON AN URBANIZING WATERSHED IN VIRGINIA, USA

  • Im, Sang-Jun;Brannan, Kevin-M.;Mostaghimi, Saied
    • Water Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.141-154
    • /
    • 2003
  • Nonpoint source pollutants from agriculture are identified as one of the main causes of water quality degradation in the United States. The Hydrological Simulation Program-Fortran (HSPF) was used to simulate runoff, nitrogen, and sediment loads from an urbanizing watershed; the Polecat Creek watershed located in Virginia. Model parameters related to hydrology and water quality were calibrated and validated using observed hydrologic and water quality data collected at the watershed outlet and at several sub-watershed outlets. A comparison of measured and simulated monthly runoff at the outlet of the watershed resulted in a correlation coefficient of 0.94 for the calibration period and 0.74 for the validation period. The annual observed and simulated sediment loads for the calibration period were 220.9 kg/ha and 201.5 kg/ha, respectively. The differences for annual nitrate nitrogen ($NO_3$) loads between the observed and simulated values at the outlet of the watershed were 5.1% and 42.1% for the calibration and validation periods, respectively. The corresponding values for total Kjeldahl nitrogen (TKN) were 60.9% and 40.7%, respectively. Based on the simulation results, the calibrated HSPF input parameters were considered to adequately represent the Polecat Creek watershed.

  • PDF

Effect of Artificial Aeration System on Water Quality of Yeoncho Lake (연초호의 인공 순환 장치 운영에 의한 수질 개선 효과 분석)

  • Seo, Dong-Il;Hwang, Hyun-Dong;Lee, Eun-Hyoung;Heo, Woo-Myung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.357-365
    • /
    • 2004
  • Effect of artificial circulation on amelioration of water quality in Yeoncho Lake was analyzed using summer data between 1991-2002. Two sites, intake tower area where aeration systems are concentrated in and near the inlet of reservoir were selected for comparison in this study. Summer averages between may and september Showed that aeration system might be beneficial in the improvement of water quality of BOD5, COD, and TN while Chl-a concentration and transparency did show opposite pattems. Wilcoxon's singed rank test for matched pair indicated slight increase of BOD5 and COD concentrations in the vicinity of intake tower while other variables did not show any significant differences from data of inlet of reservoir. During the study, it was found that the following subjects need to be investigated for more detailed analysis. 1) Dynamic pollutant loading from outside and inside the lake, 2) Biological, Chemical and Physical lake data when aeration systems are in and not in operation and 3) Radius of influence of aeration system.

Estimating Chlorophyll-a Concentration using Spectral Mixture Analysis from RapidEye Imagery in Nak-dong River Basin (RapidEye영상과 선형분광혼합화소분석 기법을 이용한 낙동강 유역의 클로로필-a 농도 추정)

  • Lee, Hyuk;Nam, Gibeom;Kang, Taegu;Yoon, Seungjoon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.329-339
    • /
    • 2014
  • This study aims to estimate chlorophyll-a concentration in rivers using multi-spectral RapidEye imagery and Spectral Mixture Analysis (SMA) and assess the applicability of SMA for multi-temporal imagery analysis. Comparison between images (acquired on Oct. and Nov., 2013) predicted and ground reference chlorophyll-a concentration showed significant performance statistically with determination coefficients of 0.49 and 0.51, respectively. Two band (Red-RE) model for the October and November 2013 RapidEye images showed low performance with coefficient of determinations ($R^2$) of 0.26 and 0.16, respectively. Also Three band (Red-RE-NIR) model showed different performance with $R^2$ of 0.016 and 0.304, respectively. SMA derived Chlorophyll-a concentrations showed relatively higher accuracy than band ratio models based values. SMA was the most appropriate method to calculate Chlorophyll-a concentration using images which were acquired on period of low Chlorophyll-a concentrations. The results of SMA for multi-temporal imagery showed low performance because of the spatio-temporal variation of each end members. This approach provides the potential of providing a cost effective method of monitoring river water quality and management using multi-spectral imagery. In addition, the calculated Chlorophyll-a concentrations using multi-spectral RapidEye imagery can be applied to water quality modeling, enhancing the predicting accuracy.

Determining chlorine injection intensity in water distribution networks: a comparison of backtracking and water age approaches

  • Flavia D. Frederick;Malvin S. Marlim;Doosun Kang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.170-170
    • /
    • 2023
  • Providing safe and readily available water is vital to maintain public health. One of the most prevalent methods to prevent the spread of waterborne diseases is applying chlorine injection to the treated water before distribution. During the water transmission and distribution, the chlorine will experience a reduction, which can imply potential risks for human health if it falls below the minimum threshold. The ability to determine the appropriate initial intensity of chlorine at the source would be significant to prevent such problems. This study proposes two methods that integrate hydraulic and water quality modeling to determine the suitable intensity of chlorine to be injected into the source water to maintain the minimum chlorine concentration (e.g., 0.2 mg/l) at each demand node. The water quality modeling employs the first-order decay to estimate the rate of chlorine reduction in the water. The first method utilizes a backtracking algorithm to trace the path of water from the demand node to the source during each time step, which helps to accurately determine the travel time through each pipe and node and facilitate the computation of time-dependent chlorine decay in the water delivery process. However, as a backtracking algorithm is computationally intensive, this study also explores an alternative approach using a water age. This approach estimates the elapsed time of water delivery from the source to the demand node and calculate the time-dependent reduction of chlorine in the water. Finally, this study compares the outcomes of two approaches and determines the suitable and effective method for calculating the chlorine intensity at the source to maintain the minimum chlorine level at demand nodes.

  • PDF

A study on improvement of painting quality through a de-painting phenomenon of KUH-1 tail blade (한국형 기동헬기 꼬리 날개 디페인팅 현상을 통한 도장 품질 향상에 관한 연구)

  • Chang, In-Ki;Kim, Young-Jin;Seo, Hyun-Soo;Jeon, Boo-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.325-338
    • /
    • 2014
  • Purpose: The purpose of this study was to explain de-painting phenomenon of KUH-1 tail blade and to propose useful solution of it by test. The proposed solution was evaluated by real flight, and then it applied to mass product to improve the paint qual ity of KUH-1 tail blade. Methods: This study investigated an adhesive ability of primer following surface sanding condition. The cross cut and scratch test were conducted to evaluate the adhesive strength. And the water flow test was designed to simulate a real flight condition under rain. Through water flow test, an optimal condition of tail blade to prevent a de-painting phenomenon was deduced. Finally, the improvement method was evaluated by real flight under rain. Results: The results of this study are as follows; The sequential polishing was most excellent method in primer painting quality. The results of test including cross cut, scratch and water flow showed that MIL-DTL-53039 paint with epoxy primer has excellent adhesive ability. To proof the effect of improvement, a real flight during a rain condition was conducted. Finally, the comparison between original and improved configuration was conducted. Conclusion: The painting quality of KUH-1 tail blade was improved through deriving an optimal painting condition. In detail, a condition of optimal sanding and a sort of primer and paint was showed. Finally, the reliability of tail blade was guaranteed through improving the quality of painting.