농업용 저수지의 수질특성과 수질개선 -왕궁저수지를 대상으로 - (Characteristics and Improvement of the Water Quality in Wangkung Reservoir)

  • 윤경섭;이광식;김형중;황길순
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.365-368
    • /
    • 2002
  • In spite of considerable advances in water quality control measures within lake, many basic questions concerning an eutrophication still remains unanswered and it becomes obvious that an extensive limnological database is needed for the inter-comparison between bodies of water and for the assessment of the status of lake water quality. In order to diagnose the water environment and assess the changes of the water quality, Wangkung irrigation reservoir was investigated by a long-term monitoring program for the physical, chemical and biological water quality parameters. In addition, these data was used to determine the design elements of natural purification facilities.

  • PDF

Strain Identification and Comparative Analysis of Toxigenic Cyanobacteria Determined by PCR

  • Jung Jong-Mun;Jung Eun-Young;LEE You-Jung;Park Hong-Ki;Jung Mi-Eun;Ji Ki-Won;Joo Gea-Jae
    • 한국환경과학회지
    • /
    • 제14권7호
    • /
    • pp.649-655
    • /
    • 2005
  • Microcystis aeruginosa is common form of cyanobacteria (blue-green algae) capable of producing toxic heptapeptide (microcystin) that cause illness or death. The comparison of molecular genetic method with the morphological characteristics of cyanobacteria was conducted. We have designed PCR primers (JJM98F, JJM1141R) for cyanobacterial 16S rRNA and phycocyanin intergenic spacer (PC-IGS) gene domain. To confirm the production of microcystins, PCR primers for the N-methyltransferase (NMT) domain of microcystin synthetase gene mcyA were designed using 21 cyanobacteria strains Most of isolated strains from the Nakdong River was classified as Microcystis aeruginosa and the similarities were $99\%$ with M. aeruginosa AF 139292. $38.1\%$ of isolated strains contained microcystin synthesis gene. NMT (N-methyltransferase) were not detected in isolated strain in several strains, which means non-toxic. However, the NMTs of the strains were detected during the cultivation.

1차원 수질 예측 모형의 검보정 자동화 시스템 개발 및 낙동강에서의 적용 (Development of 1-Dimensional Water Quality Model Automatizing Calibration-Correction and Application in Nakdong River)

  • 손아롱;한건연;박경옥;김병현
    • 환경영향평가
    • /
    • 제20권5호
    • /
    • pp.765-777
    • /
    • 2011
  • According to the total pollution load management system, exact prediction and analysis of water quality and discharge has been required in order to allocate the amount of pollution load to each local government. In this study, QUAL2E model was used for comparison with other water quality models and improve the inadequate to forecast future water quality. And Various calibration and verification methods were applied to deal with existing uncertainties of parameter during modeling water quality. For user convenience, A GUI(Graphical User Interface) system named "QL2-XP" model is developed by object-oriented language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis, water quality analysis, optimized model calibration processes, and postprocessing the simulation results. Therefore this model will be effectively utilized to manage practical and efficient water quality.

공간모형을 이용한 수질오염물질의 공간적 예측 및 평가에 대한 연구 (A Study on Spatial Prediction of Water Quality Constituents Using Spatial Model)

  • 강태구;이혁;강일석;허태영
    • 한국물환경학회지
    • /
    • 제30권4호
    • /
    • pp.409-417
    • /
    • 2014
  • Spatial prediction methods have been useful to determine the variability of water quality in space and time due to difficulties in collecting spatial data across extensive spaces such as watershed. This study compares two kriging methods in predicting BOD concentration on the unmonitored sites in the Geum River Watershed and to assess its predictive performance by leave-one-out cross validation. This study has shown that cokriging method can make better predictions of BOD concentration than ordinary kriging method across the Geum River Watershed. Challenges for the application of cokriging on the spatial prediction of surface water quality involve the comparison of network-distance-based relationship and euclidean-distance-based relationship for the improvement in the predictive performance.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • 제24권4호
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

한국과 중국의 콘크리트용 화학 혼화제 품질 규정 비교 (Comparison of Quality Standards of Chemical Admixtures for Concrete between Korea and China)

  • 후윈야오;임군수;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.97-98
    • /
    • 2023
  • In this study, comparison of the quality standard of chemical admixtures between Korea and China is conducted. It is classified into three types of water reducing agents: standard, delayed, and accelerated according to the sensitivity and strength improvement of the sensitivity and strength of the agent. However, Chinese standards classify reducing agents only as standard, high efficiency, and high performance, and do not add AE agents into water reducing agent. On the other hand, that of Korea has a classification regulation for reducing agents added with AE agents.

  • PDF

단순회귀모형을 이용한 인구와 도시적 토지이용이 팔당호 수질에 미치는 영향 분석 (Analysis for the Effect of Population and Urban Land use on the Water Quality in Paldang Lake Using Simple Regression Model)

  • 김상단;송미영;이기영;이성룡
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.703-707
    • /
    • 2004
  • In this study, a simple regression model is proposed in order to analyse the effect of population and urban land use on the water quality of Paldang lake, Gyeonggi. As a comparison result with Qua12E water quality model, the proposed model shows very good predicting performance in simulating several alternative scenarios. In order to accomplish BOD 1ppm of Paldang lake, various model applications show that the population incoming and urban land use management should be afoot in addition to stricter outflow water quality from sewer treatmement systems.

부산지역 3개 하천의 수질 특성 비교 (Water Quality Comparison in the Three Streams of Pusan Area)

  • 황선출;이봉헌
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.165-170
    • /
    • 1998
  • The purpose of thins study was to investigate the pollutions of water Qualities in 30 water samples from Nakdong River Western Nakdong River, and Suyoung Stream. COB, BOD. T-N and negative ion(F, Cl+, NO3-, SO42-) of water samples were analysed and the correlationships between water qualities were examined. The mean concentrations of COD(20.26ppm), BOD(25.36ppm), and T-N(18.05ppm) were the highest in the water sample of Suyoung Stream among the three streams and those of F-(0.25ppm), Cl+(2770ppm), and SO42-(37.66ppm) In Western Nakdong River, that of NO3-(10.8 ppm) in Nakdong River. The water quality of Suyoung Stream was the worst among the three streams in hsn area. The correlationships between water qualities were as follows , BOD and COD showed very high correlationship(correlation cofficient, r=0.97),50,2- and NO3'did high one(0.75), and NOa'and COD, BOD did relatively high ones(0.56 and 0.48, respectively).

  • PDF

공동주택 지하저수조의 수질변화 및 부식성 특성 (Water Quality Variation and Corrosion Index Characteristics of Underground Reservoir in Apartment)

  • 장준영;김주원;황유훈;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제38권6호
    • /
    • pp.275-281
    • /
    • 2022
  • To maintain water quality after water treatment, monitoring whether the quality of treated tap water quality changes is essential. However, current investigations are insufficient to prevent secondary contamination in drinking water supply systems. This study investigated Gyeonggi's e apartment where a red water problem occurred and monitored the water quality and corrosiveness of the overall water supply system to the apartment from June 2021 to April 2022. In a comparison of drinking water quality after water treatment and the influent of the reservoir, turbidity and heavy metal concentrations were increased and residual chlorine was decreased due to increases in temperature. Correlation analysis and principal component analysis (PCA) indicated that a low level of residual chlorine may cause the abscission of Mn2+ and Fe2+ through microorganism activation, which also causes a high level of turbidity. The corrosion index (LI) in the influent of the reservoir tank was increased due to Ca2+ and temperature. These results indicate that the corrosiveness of drinking water and the deterioration of drinking water quality were mainly increased between the drinking water treatment plant and the reservoir tank's influent. The findings provide clear evidence that it is essential to manage water supply systems and reservoir tanks to prevent the secondary contamination of drinking water.

하천수질오염이 농업용수에 미치는 영향 (Effect of Water Pollution on the Irrigation Water)

  • 나규환;이장훈;김치년
    • Environmental Analysis Health and Toxicology
    • /
    • 제6권3_4호
    • /
    • pp.155-161
    • /
    • 1991
  • The water quality in Wonju stream, Seom river in Kangwon province and Bokha, Shindun stream in Kyeonggi province was investigated between the season of irrigation on July, 1990 and of non-irrigation on September in 1989. The results of water quality obtained from this study were as follows; As for water quality of the Wonju stream and the Seom river, the concentration of COD, T-N, SS and Cu, and for the Bokha, Shindun stream, the concentration of T-N, SS and Cu were exceeded standard levels of quality guideline of agricultural water use in the season of irrigation. However, in the water quality of Wonju and Bokha stream, the concentration of T-N , SS and Cu, and in the Seom river, the concentration of T-N, SS, Cu and Zn were exceeded standard levels of agricultural water quality in the season of non-irrigation. And the average water quality of the 4 streams were not suitable for agricultural water use. The comparison of the annual average water quality of the 4 streams for pH, DO, T-N and SS were in statistics significantly different with p values less than 0.01. When the average water quality between the season of irrigation and non-irrigation in each stream was compared, DO and COD in the Wonju stream, COD in the Seom river, pH, DO, T-N, SS and Cu in the Shindun stream showed a significant difference with p<0.01. The average in the sediment were; COD, 5.65∼26.53 ppm; Cu, 0.26∼0.49 ppm and Zn 0.95∼2.97 ppm. The concentration of three contaminants were markedly higher than the water quality. And the concentration of COD, Zn in the sediment showed a significant difference with p<0.01, and Cu showed a considerably significant difference with p<0.05.

  • PDF