• Title/Summary/Keyword: Water quality characteristic

Search Result 327, Processing Time 0.029 seconds

Sensory Characteristics of Korean Wheat Noodles With Pine pollen and Antioxidant activities of Pine pollen Extracts (송화를 첨가한 우리밀 국수의 관능특성 및 송화추출물의 항산화성)

  • Kim, Mi-Lim
    • Korean journal of food and cookery science
    • /
    • v.21 no.5
    • /
    • pp.717-724
    • /
    • 2005
  • Sensory characteristics and antimicrobial activity of Korean wheat noodle with pine pollen powder and antioxidant activity of pine pollen extracts were investigated to develop the health promoting product. Pine pollen powder was extracted with water and 70% ethanol and extracts were tested electron donating ability (EDA) and nitrite scavenging ability (NSA). Sensory characteristics were evaluated by its color, flavor, moisture, softness, texture and taste. Microbiological quality was tested by total viable cells. EDA was highest in 1,000 ppm for both water extract (67% of EDA) and ethanol extract (74% of EDA). NSA was highest in pH 1.2 for both water extract(46% of NSA) and ethanol extract (48% of NSA). Antimicrobial activity of Korean wheat noodle with 3% pine pollen powder were 0.5 log $cycle{\sim}1$ log cycle lower than that of control at 5days of storage in total vival cells and at 4days of storage in total fungus. From sensory evaluation, Korean wheat noodle with 3% pine pollen powder had significantly higher of all scores.

Analysis of Numerical Experiment for Field Application of Cylindrical Slit Type Block Breakwater (실린더 슬릿형 소파블록 방파제의 실해역 적용을 위한 수치실험분석)

  • Park, Sang-Gil;Lee, Joong-Woo;Nam, Ki-Dae;Kim, Pill-Sung
    • Journal of Navigation and Port Research
    • /
    • v.33 no.10
    • /
    • pp.703-707
    • /
    • 2009
  • In order to evaluate applicability of cylindrical slit type block breakwater to the field water, which was designed from the previous physical model study, it is analyzed the calmness of harbor area by the numerical model experiment. For a small fishery port in southern coast of Korea a SWAN model using the wave action balance equation was formulated. The reflection and transmission coefficients induced by the physical model test were introduced to the numerical model. The model response with cylindrical slit type breakwater was compared with the impermeable breakwater case and the possibility of water quality improvement through the water circulation by the new structure was investigated. For numerical simulation, parameters of deepwater design wave from the prediction report II for overall deepwater design wave by KORDI were used and wind parameters from the 50years return period observed for 37years(1970~2006) were adopted in the numerical model. The response of west breakwater in Mijo port applying the NE and NNE waves, which were dominant in this area, was analyzed. It was found that the transmission characteristic of designed cylindrical slit breakwater was well presented in the numerical model.

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

Spatial and Temporal Distribution of Zooplankton Communities in Lake Paldang (팔당호 동물플랑크톤 군집의 시공간적 분포)

  • Sim, Youn-Bo;Jeong, Hyun-Gi;Im, Jong-Kwon;Youn, Seok-Jea;Byun, Myeong-Seop;Yoo, Soon-Ju
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.4
    • /
    • pp.287-298
    • /
    • 2018
  • The zooplankton community and environmental factor were investigated on a weekly basis from March to November 2015 in Lake Paldang, Korea. The seasonal succession of zooplankton community structure was influenced by hydraulic and hydrological factors such as inflow, outflow and rainfall. However, the hydraulic retention time in 2015 (16.3 day) was affected by the periods of water shortage that had continued since 2014 and increased substantially compared to 2013 (7.3 day). Therefore, the inflow and outflow discharge were decreased, and the water quality (COD, BOD, TOC, TP, Chl-a) of Lake Paldang (St.1) was the same characteristics as the river type Bukhan river (St.3), compared with the lake type Namhan river (St.2) and Gyeongan stream (St.4). Zooplankton community dominated by rotifers (Keratella cochlearis, Synchaeta oblonga) in spring (March to May). However, Copepod (Nauplius) and Cladoceran (Bosmina longirostris) dominated in St.4. In summer (June to August), there was a few strong rainfall event and the highest number of individuals dominated by Keratella cochlearis (Rotifera) and Difflugia corona (Protozoa) were shown during the study period. In autumn (October to November), the water temperature was decreased with decrease in the total number of individuals showing Nauplius (Copepoda) as the dominant species. As a result of the statistical analysis about zooplankton variation in environmental factors, the continuous periods of water shortage increased the hydraulic retention time and showed different characteristic for each site. St.1, St.3 and St.2, St.4 are shown in the same group (p<0.05), showing the each characteristics of river type and lake type. Therefore, the water quality of catchment area and distribution of zooplankton community would be attributed to hydraulic and hydrological factors.

Build-Up a Kinematic Wave Routing System for the Catchment-Stream Complex (사면 및 하도 복합유출장의 단기 유출해석 시스템 개발)

  • Ha, Sung Ryong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.875-886
    • /
    • 1994
  • This study is to develop an advanced storm runoff analysis program which takes geomorphological characteristics of watershed into consideration in determining model parameters. Basic concept of storm runoff modelling is based upon the kinematic wave theory. And numerical solution is obtained by the characteristic curve method. The storm runoff analysis program developed by this study is composed of multiple equivalent roughness sub-basins, each of which has two equivalent catchments on both side of a stream. Because it is based upon the stream-order of the Strahler system, the equivalent catchment-stream network reflects the stochastic geomorphological characteristics in the model parameter. Applicability and reliability of the storm runoff analysis program is evidenced by model calibration and verification process utilizing geographical and hydrological data of the Bocheong-river area which is a representative watershed of IHP projects in Korea. This study will hopefully contribute to hydrological calculation essentially required to understand water quality effect caused by regional development.

  • PDF

Characteristic of Cementitious Mortar Using High Volume of Recycled Fine Aggregate (순환잔골재의 다량 사용에 따른 모르타르의 특성)

  • Kim, Sang-Chel;Park, Do-Kuk;Yoog, Keun-Chang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • As for a possibility of using high volume of recycled aggregate in concrete mixture, recycled fine one which is known to be worse in quality and hard to control was selected and investigated in terms of performance of mortar as the replacement ratio to natural fine aggregate was changed. As a result of test, it is found that grade of recycled fine aggregate was beyond standard one and fineness modulus of that itself was increased in compare to natural one. In case of making mortar with recycled fine aggregate, disadvantageous results such as less fluidity and air content including the increase of dry shrinkage were shown but strengths of mortar were comparable to the one making with natural aggregate, which means that planned strength of common concrete structure can be achieved by controlling W/C and the amount of chemical admixture, and also that large amount of recycled fine aggregate is applicable to the precast concrete products generally free to the amount of water.

Monitoring the Hydrologic Water Quality Characteristics of Discharge from a Flat Upland Field (평지 전작 유출수의 수문·수질 특성 모니터링)

  • Park, Chanwoo;Oh, Chansung;Choi, Soon-Kun;Na, Chae-in;Hwang, Syewoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.3
    • /
    • pp.109-121
    • /
    • 2020
  • Converting the agricultural land-use of rice field to upland has been increasingly conducted as farmers encourages themselves to grow higher value-added crops on rice fields under the policy support. Comparing to rice field, Upland shows different characteristic of discharge due to the slope, scale, and shape of field and characteristics of rainfall event. In this study, we designed the experiment fields reflecting flat-upland characteristics with different land scale, and tried to collect the discharge and load data. Soybeans and corn were selected as target crops considering the possibility of large-scale cultivation and crop demand. The cultivation was conducted during the growth period in 2019 with 3 different field scales. Hence, we have collected the discharge data from 17 rainfall events and the load data for 8 rainfall events. As a result, the magnitude of rainfall events and the discharge duration were found to have a strong positive correlation and field discharge occurred during the period by 55% to 83% of rainfall duration. Besides we found other relationships and characteristics of rainfall event, discharge, and pollutant load and also pointed out that continuous monitoring and more data are required to derive statistically significant results. Compared with slope-field monitoring data obtained from the precedent research, the runoff ratio of the flat-fields was significantly lower than slope-fields. Overall the discharge in the slop and flat-fields shows appreciably different characteristics so that the related researches need to be further conducted to reasonably assess environmental impact of agricultural activities at flat-field.

Quality Improvement of Oil Palm Trunk Properties by Close System Compression Method

  • Hartono, Rudi;Wahyudi, Imam;Febrianto, Fauzi;Dwianto, Wahyu;Hidayat, Wahyu;Jang, Jae-Hyuk;Lee, Seung-Hwan;Park, Se-Hwi;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.172-183
    • /
    • 2016
  • Densification of the inner part of oil palm trunk (OPT) by the close system compression (CSC) method was performed in this study. The effects of the compression temperature and time on the anatomical, physical and mechanical properties of OPT were evaluated. The inner part of OPT with an initial average density of $0.3g/cm^3$ was used as samples. Oven-dried samples were immersed in water and vacuumed until fully saturated and then compressed by CSC at 120, 140, 160 or $180^{\circ}C$ for 10, 20, 30 or 40 min. The anatomical characteristics of transverse and radial sections before and after compression were compared by optical microscopy. The physical and mechanical properties, including the density, recovery of set (RS), modulus of elasticity (MOE), modulus of rupture (MOR), and compression parallel to grain were examined. It was observed that the anatomical characteristic of the inner part of OPT (i.e., vascular bundles, vessels, and parenchyma tissue) became flattened, fractured, and collapsed after compression by CSC. The RS decreased with increasing compression temperature and time. The lower RS indicated high dimensional stability. The physical and mechanical properties (i.e., density, MOR, MOE, and compressive strength) of the inner part of OPT increased with increasing compression temperature and time. Compression by the CSC method at $160^{\circ}C$ for 40 min was the optimum treatment.

Effects of Zn-L-Selenomethionine on Carcass Composition, Meat Characteristics, Fatty Acid Composition, Glutathione Peroxidase Activity, and Ribonucleotide Content in Broiler Chickens

  • Chaosap, Chanporn;Sivapirunthep, Panneepa;Takeungwongtrakul, Sirima;Zulkifli, Razauden Mohamed;Sazili, Awis Qurni
    • Food Science of Animal Resources
    • /
    • v.40 no.3
    • /
    • pp.338-349
    • /
    • 2020
  • The effects of organic Zn-L-selenomethionine (Zn-L-SeMet) at 0.3 ppm on carcass composition, meat characteristics, fatty acid composition, glutathione peroxidase activity, and ribonucleotide content were compared against the commercial inorganic sodium selenite (Na-Se) and the combination of the two, in commercial broilers. A total of 540 one day-old chicks were assigned at random to 3 dietary treatments : i) commercial inorganic selenium as control or T1, ii) a 1:1 ratio of inorganic and organic selenium as T2, and iii) organic selenium as T3. Carcass composition, meat characteristics, cholesterol content, fatty acid composition, and ribonucleotide content were generally unaffected by treatments. However, discrepancy were significantly observed in glutathione peroxidase activity (GSH-Px) and water holding capacity, with organic selenium showing higher glutathione peroxidase activity (p<0.01) and lower shrinkage loss (p<0.05), respectively. These findings could be explained by the contribution of organic selenium in bioavailability of GSH-Px. However, having conducted in a commercial close house system with sufficient amount of nutritional supplementation, the present study demonstrated little or no effects of organic Zn-L-SeMet on meat characteristics, fatty acid composition, and ribonucleotide content (flavor characteristic) in broiler chickens.

Studies on the Improvement of Butt Welding Characteristic of Polyethylene Pipes (PE 이중벽관의 맞대기 융착 용접 강도 향상에 관한 연구)

  • An, Ju-Seon;Lee, Kyng-Won;Kim, Jae-Sung;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.85-89
    • /
    • 2011
  • Waste water is disposed to sewage disposal plant by underground PE double wall pipes. Various processes have been introduced to join PE pipes, but most of these methods have many disadvantages such as costs, lack of reliability and difficulties in joining, etc. Recently butt welding has been paid much attention to joint PE pipes as this process has many advantages such as cost, safety and reliability. In this study, newly developed heat plate, a patent-pending heat plate with a groove, was used to butt-weld PE double wall pipes with different misalignment gaps to simulate real underground conditions, and the butt welding temperature of PE pipe was determined by thermal analysis (Thermal Gravimetric Analysis, Differential Scanning Calorimetry and Dynamic Mechanical Analysis). The resulting joining characteristics of double wall pipes were compared with those from a conventional heat plate, in terms of stiffness, flattening and leakage tests. The results from the stiffness and flattening test showed that there were no big differences between the butt-welded joints made from these two plates. From the leakage test, although PE pipes welded with a conventional heat plate did leak below the required test conditions (10 min. at 0.75kgf/cm2), the pipes welded with a patent-pending grooved heat plate did not show any leakage even at a pressure 1.5 times higher than the required conditions. It was noted that by utilizing a grooved heat plate more complete fusion at the pipe joints could be obtained, which in turn induced a high quality joints.