• 제목/요약/키워드: Water purification processes

검색결과 63건 처리시간 0.027초

조석분류를 이용한 연안해역의 수질정화에 관한 수치적 평가 (Numerical Assessment for Coastal Water Purification Utilizing a Tidal Jet System)

  • 박종천
    • 한국해양공학회지
    • /
    • 제20권4호
    • /
    • pp.58-63
    • /
    • 2006
  • When the costal zone surrounded by a breakwater has a narrow vertical opening, currents in the vicinity of a narrow entrance can result in a jet flow, coinciding with the tide. Such a Tidal-Jet Generator(TJG) can change the water mass distribution and transport processes in the domain of influence of the jet. Also, it can decrease the residual time of them. In the present study, the water purification utilizing tidal jets in the coastal zone over constant bathymetry are estimated numerically, using a finite-difference numerical scheme, named the NS-MAC-TIDE method, which isbased on the fully 3D Navier-stokes(NS) equations. The shear velocity near the inlet of the TJG are predicted from the flow field simulation, and are assessed qualitatively with the development of scouring or sediment that is caused by the change of diffusion or sweeping flowup from the seabed of sediment particles. Finally, through solving a transport equation of concentration, the residual time related on mass transport processes and the flushing mechanism for water purification are investigated.

시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 - (Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System -)

  • 이광야;최경숙
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

분리막 및 광촉매의 혼성 정수/하수 처리 공정 (Hybrid Water/Wastewater Treatment Process of Membrane and Photocatalyst)

  • 박진용
    • 멤브레인
    • /
    • 제28권3호
    • /
    • pp.143-156
    • /
    • 2018
  • 본 총설은 다양한 저널 게재 논문으로부터 분리막 및 광촉매의 혼성 정수/하수 처리 공정을 요약하였다. 이 총설에는 (1) 분리막 광촉매 반응기(membrane photoreactor, MPR), (2) 분리막 결합 광촉매 공정에서 막오염 관리, (3) 유기 오염물의 분해를 위한 광촉매 분리막 반응기, (4) 정수처리용 막분리 공정과 광촉매 분해의 결합, (5) 휴믹산 분해를 위한 광촉매 및 세라믹 막여과의 혼성공정, (6) 활성슬러지 여과를 위한 한외여과의 막오염에 이산화티타늄 나노입자의 영향, (7) 정수처리용 광촉매 및 정밀여과의 혼성시스템, (8) 선박 평형수 처리용 한외여과 및 광촉매의 혼성공정 및 (9) 분리막 및 광촉매 코팅 프로필렌 구의 혼성수처리 공정이 포함되어 있다.

상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발 (Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network)

  • 정보배;김기범;서지원;구자용
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

정수장 시설공사의 통합관리를 위한 시설물분류체계 개발 (The Development of Information Breakdown Structure for Integrated Management of Water Filtration Plants)

  • 김창학;강인석;김효진
    • 대한토목학회논문집
    • /
    • 제37권5호
    • /
    • pp.863-869
    • /
    • 2017
  • 본 연구에서는 다양한 정수처리공법과 시설을 분류하여 정수장의 시설물 정보분할코드체계를 구축하였으며, 이것은 정수장 시설의 생애주기 동안 소요되는 유지관리비용, 에너지 사용비용 산정 및 배출된 환경오염원의 규명과 환경영향평가의 정량적 분석 등을 위한 정보를 통합하기 위한 전산시스템의 코드체계로 활용하게 된다. 건설공사의 정보는 많은 이질정보를 포함하고 있기 때문에 이를 통합해서 관리하기 위한 코드체계가 매우 중요하다. 또한 정수장 시설은 많은 프로세스를 포함한 시설물 설치공사가 주를 이루기 때문에 좀 더 세분화된 분활코드가 필요하다. 따라서 본 연구에서는 국내에서 시도되지 않은 정수장 관련 분류체계를 건설공사 분류체계인 파셋 분류체계 표현방식을 활용하여 구축하였다.

단위공정별 기초실험을 통한 다기능 융복합부도의 설계·운전인자 도출 (Design and operating parameters of multi-functional floating island determined by basic experiments of unit processes)

  • 임현만;장여주;정진홍;윤영한;박재로;김원재
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.487-497
    • /
    • 2018
  • Water quality improvement processes for stagnant area consist mainly of technologies applying vegetation and artificial water circulation, and these existing technologies have some limits to handle pollution loads effectively. To improve the purification efficiency, eco-friendly technologies should be developed that can reinforce self-purification functions. In this study, a multi-functional floating island combined with physical chemical biological functions ((1) flotation and oxidization using microbubbles, (2) vegetation purification and (3) bio-filtration with improved adsorption capacity) has been developed and basic experiments were performed to determine the optimal combination conditions for each unit process. It has been shown that it is desirable to operate the microbubble unit process under conditions greater than $3.5kgf/cm^2$. In vegetation purification unit process, Yellow Iris (Iris pseudacorus) was suggested to be suitable considering water quality, landscape improvement and maintenance. When granular red-mud was applied to the bio-filtration unit process, it was found that T-P removal efficiency was good and its value was also stable for various linear velocity conditions. The appropriate thickness of filter media was suggested between 30 and 45 cm. In this study, the optimal design and operating parameters of the multi-functional floating island have been presented based on the results of the basic experiments of each unit process.

오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술 (Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage)

  • 최성민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.167-177
    • /
    • 2014
  • 최근 수질오염의 악화로 고도정수처리시설에 대한 수요가 커지고 있으며, 오존처리와 같은 밀폐형 고도정수처리시설의 설치가 늘고 있는 실정이다. 그러나 오존의 강력한 산화작용으로 인해 콘크리트 구조물의 침식이 우려됨에 따라 오존에 대응 가능한 에폭시 방수방식재가 콘크리트 표층부 보호 코팅재로 적용되고 있다. 그러나 이러한 에폭시가 오존에 대한 성능수준 및 장기적 내구성을 명확히 측정할 방법과 기준이 없어 정확한 품질관리가 이루어지지 않고 있는 실정이며, 이로 인해 수처리용 콘크리트 구조물의 장기내구성 확보에 대한 우려가 제기되고 있다. 이 연구에서는 AFM과 나노인덴테이션 기법이 기존에 사용하던 평가방법인 육안관찰, 중량변화, 표면관찰, 색차분석 등의 간접적 평가방법과 함께 에폭시 방수방식재 평가방법으로써의 적합한지를 판단하고자 하였으며, 이를 위해 오존용으로 개발된 6종의 다른 성분으로 구성된 에폭시계 방수방식재를 대상으로 열화특성을 분석하였다. 연구결과 AFM과 나노인덴테이션을 활용할 경우 기존 평가방법보다 직접적이고 정량적인 평가가 가능함을 확인하였으며, 일부 에폭시 코팅재료의 경우 오존에 대한 성능 한계치 (임계치)를 명확히 확인할 수 있었다.

챔버 내측에 스프링형상을 갖는 유수형 자외선 살균장치 시뮬레이션 (Simulation for the Flowing Water Purification with Spring Shape Inside Chamber)

  • 정병균;정병호;이진종;정병수
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.411-416
    • /
    • 2010
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. In this paper, It describe the how to design optimal UV disinfection device for ground water, BWT and rainwater. Spring shape instrument silver coated located in inner side of disinfection chamber. It make lead the active flowing movement target water and maximize disinfection performance. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Adaptive method for the purification of zinc and arsenic ions contaminated groundwater using in-situ permeable reactive barrier mixture

  • Njaramba, Lewis Kamande;Nzioka, Antony Mutua;Kim, Young-Ju
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.283-288
    • /
    • 2020
  • This study investigated the purification process of groundwater contaminated with zinc and arsenic using a permeable reactive barrier with a zero-valent iron/pumice mixture. We determined the removal rates of the contaminants for 30 days. In this study, column reactor filled with the zero-valent iron/pumice reactive mixture was used. Experimental results showed that the mixture exhibited an almost complete removal of the zinc and arsenic ions. Arsenic was removed via co-precipitation and adsorption processes while zinc ions were asorbed in active sites.The purification process of water from the metal ionscontinued for 30 days with constant hydraulic conductivity because of the enhanced porosity of the pumice and interparticle distance between the zero-valent iron and pumice. Contaminants removal rates and the remediation mechanism for each reactive system are described in this paper.

미생물에 의한 발효처리 (Wastewater Treatment by Microorganism)

  • 신석봉
    • 한국미생물·생명공학회지
    • /
    • 제8권2호
    • /
    • pp.135-142
    • /
    • 1980
  • The process of biological treatment of organic wastewater is principally associated with those of self-purification in the natural water environment. The treatment system has e intensive function of stabilizing wastewater more effectively than in natural water, which is like natural water concentrated in a small space. Biological treatment of wastewater involves activated sludge and various modified process, trickling filter, rotating disk, oxidation ditch, etc. for aerobic decomposition and anaerobic processes such as anaerobic decomposition and methane fermentation. The basic characteristic of these processes is the use of mixed culture for the conversion of pollutants. This review forcuses on the various kinds of microorganisms related to each treatment processes. Kinetic analysis of the activated sludge process is discussed in order to understand the basis of control and maintenance of the biological treatment process.

  • PDF