• Title/Summary/Keyword: Water pollutants

Search Result 1,455, Processing Time 0.025 seconds

Removal Characteristics of Rainwater Including Non-point Pollutants Using Pre-filter of Wasted-tire and Non-woven Fabric (폐타이어와 부직포를 이용한 프리필터에 의한 비점오염원 포함 우수 처리 특성)

  • Yoo, Kyuseon;Han, Hakyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.655-659
    • /
    • 2005
  • Pre-filter system that was consisted of wasted-tire, non-woven fabrics, and sponge was developed as a primary treatment process prior to rainwater reservation or a pre-treatment process of rainwater reuse system for reclamation. By using this system, SS concentration, TOC, COD, and turbidity could decreased by 86.7%, 62.6%, 69.1% and 66.5%, respectively. From the results of particle size distribution of treated water, the particles over than $30{\mu}m$ of diameter were completely removed by pre-filter system. But 90% of particles less than $20{\mu}m$ of diameter were passed through pre-filter. Optimal depth of wasted-tire and non-woven fabrics were 15cm and 2.4cm, respectively. Pre-filter system was considered as an effective alternative for pre-treatment of rainwater including non-point pollutants and it could be also applied for the treatment of combined sewer overflow (CSO).

울산지역의 지하수 수질에 관한 통계학적 연구

  • 양운진
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.461-466
    • /
    • 1998
  • One hundred and thirty two ground water samples from the Usan area were divided into urban and non-urban groupings and were assessed between 1993 and 1996. The results of statistical analysis were as follows: There were significant differences between the two groupings in the average value of the following water quality parameters: total hardness, nitrate , pH, iron, ammonia and chloride ion in the order of Z-score . Because total hardness, nitrate, and pH were also significant in ANOVA test, these three parameters can be regarded as the most sensitive parameters of artirial pollutants. By the comprehensive com- parison of Ulsan water Quality to that of Kangwon-do, all of the major parameters(pH, KMnO4 consumption, sulfate, chloride and hardness except nitrated were confirmed as being significantly Increased levels.

  • PDF

Studies on the Separation Performances of Chlorophenol Compounds from Water by Thin Film Composite Membranes

  • Yogesh, K.M. Popat;Ganguly, B.;Brahmbhatt, H.;Bhattacharya, A.
    • Macromolecular Research
    • /
    • v.16 no.7
    • /
    • pp.590-595
    • /
    • 2008
  • The pressure driven membrane process has been a breakthrough in the removal of pollutants from drinking water. These experiments examined the removal of chlorophenol compounds from water using low pressure membranes. The removal performance of the membranes was based primarily on size exclusion. Apart from size exclusion, the polarity and pKa of the compounds also influences the membrane performance. The molecular size and dipole moments of the respective molecules were calculated using a quantum chemical method. The rejection of pollutants also followed the same trend as salt rejection by the membranes.

Nonpoint Pollutants Sources Characteristics of Initial Surface Runoff on the Land Use Types (토지이용별에 따른 초기강우 유출량의 비점오염물 특성 분석)

  • Choi, Yun-Yeong;Jung, Se-Young;Choi, Jeong-Woo
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.417-426
    • /
    • 2011
  • This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban and rural zones in sangju area. The monitoring was conducted with seven events for ten months and Event mean Concentration(EMC) and First Flush Effect(FFE) of SS and BOD were calculated on the result of the water quality parameters. During rainfall event, the peak concentrations of SS and BOD were observed after 3~4 hours of rainfall in rural areas. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in urban areas. The cumulative load curves for NPS pollutants showed above the $45^{\circ}$ straight line, indicating that fist flush effect occurred in urban areas. The mean SS EMC values of rural areas ranged from 0.9~3.3mg/L, it was higher value when compare to urban areas. While the mean BOD values of urban areas were shown the highest values.

Assessment of Environmental Pollution with Tradescantia Bioassays (자주달개비 생물검정 기법을 이용한 환경오염 평가)

  • Kim Jin Gyu;Sin Hae Sik
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2004.05a
    • /
    • pp.1-15
    • /
    • 2004
  • Higher plants can be valuable genetic assay systems for monitoring environmental pollutants and evaluating their biological toxicity. Two assays are considered ideal for in situ monitoring and testing of soil, airborne and aqueous mutagenic agents; the Tradescantia stamen hair assay for somatic cell mutations and the Tradescantia micronucleus assay for chromosome aberrations. Both assays can be used for in vivo and in vitro testing of mutagens. Since higher plant systems are now recognized as excellent indicators and have unique advantages over in situ monitoring and screening, higher plant systems could be accepted by regulatory authorities as an alternative first-tier assay system for the detection of possible genetic damages resulting from the pollutants or chemicals used and produced by industrial sectors. It has been concluded that potential mutagen and carcinogen such as the heavy metals among indoor air particulates, volatile compounds in the working places, soil, and water pollutants contribute to the overall health risk. This contribution can be considerable under certain circumstances. It is therefore important to identify the level of genotoxic activity in the environment and to relate it to the biomarkers of a health risk in humans. The results from the higher plant bioassays could make a significant contribution to assessing the risks of pollutants and protecting the public firom agents that can cause mutation anuor cancer. The plant bioassays, which are relatively inexpensive and easy to handle, are recommended for the scientists who are interested in monitoring pollutants and evaluating their environmental toxicity to living organisms.

  • PDF

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Behavior of Indoor Organic Pollutants Dissolved into the Ringer's Solution (수액제에 유입되는 실내 유기오염물질의 거동)

  • 김만구;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.315-322
    • /
    • 1996
  • Recently, hospital acquired infections have an increase interest as a public problems, which are caused of indoor pollutants in hospital. Microorganisms, ethylene oxide, formaldehyde, and anesthetic gases are main hazardous pollutants in hospital. The possible pathways of the infection are a respiratory channel as well as a blood channel. The blood channel is concerned since these pollutants might be dissolved into the Ringer's solution. The objective of this research was to evaluate the removal efficiencies of adsorption trap for formaldehyde and microorganisms as indoor pollutants which permeated into the Ringer's solution. Dissolved formaldehyde in the solution was increased with the injection dose time. The amount of dissolved formaldehyde was 67.5 $\pm$ 9.5% in Ringer's solution when injection dose time was controlled about 7hrs. An adsorption trap was designed for preventing formaldehyde and microorganisms to be permeated into Ringer's solution. The adsorption trap was packed with 0.4g of active carbon (60/80 mesh) in a sterilized plastic tube (7.79 cm length, 0.46 cm i.d.) and both ends were packed with glass wool. Devised infusion set equipped with the adsorption trap showed 99.9% of removal efficiency for formaldehyde. Microorganism numbers detected on sterilized water for injection and 5% dextrose infusion used in the hospital were 2,695 $\times 10^3$ cells/l and 4,190 $\times 10^3$ cells/l, respectively. Removal efficiency by the adsorption trap was 92.3 $\pm$ 8.5% as for microorgnisms.

  • PDF

Effect of Air-mass Back Trajectory on the Chemical Composition of Cloud/Fog Water at Daegwallyeong (기류의 유입경로가 대관령 지역 안개의 화학조성에 미치는 영향)

  • Kim Man-Goo;Lee Bo-Kyoung;Kim Hyun-Jin;Hong Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.343-355
    • /
    • 2005
  • Cloud/fog water was collected at Daegwallyeong, a typical clean environmental area, by using an active fog sampler during the foggy period in 2002, The pH ranged from 3,7 to 6,5 with a mean of 5,0, but the pH calculated from average concentrations of $H^+$ was 4.4. $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ were predominant ions with average concentrations of 473,3, 463,3 and $576,0\;{\mu}eq/L$, respectively, This showed that cloud/fog water was slightly acidified, but the concentrations of major pollutants were as high as those for polluted area, suggesting effect from long range transported pollutants, Samples were categorized into four groups (E, W, S, N) by applying 48-h back trajectory analysis using the Hybrid Single-Particle Largrangian Integrated Trajectory (HYSPLIT) model. Concentrations of seasalt $(Na^+\;and\;Cl^-)$ were the highest for group E, indicating large input of seasalts by air masses transported from the East Sea. The concentrations of $SO_4^{2-}$ were slightly higher in group W but the difference was not significant. However, the concentrations of $NO_3^-$ were significantly higher in group W than those in other three groups, The median values of cloud/fog water pH for group N and W were below 4,5, which is significantly lower than median values in group E and group S, This suggests that the acidifying pollutants were transported from the Asia continents and Seoul metropolitan area cause acidification of the cloud/fog water in Daegwallyeong.

The Estimating MFFn by SWMM in The Transportation Area (SWMM 모형을 활용한 도로 형태별 초기세척비율 산정)

  • Kwon, Hun-Gak;Lee, Jae-Woon;Yi, Youn-Jeong;Shin, Suk-Ho;Lee, Chun-Sik;Lee, Jae-Kwan
    • Journal of Environmental Science International
    • /
    • v.21 no.3
    • /
    • pp.277-287
    • /
    • 2012
  • The MFFn(Mass First Flush) was analyzed for various rainy events(monitoring data from 2008 to 2009) in Transportation area(Highway, National road, Trunk road). Estimated MFFn using SWMM was evaluated by comparison with observed MFFn. MFFn was estimated by varying n-value from 10% to 90% on the rainy events. The n-value increases, MFFn is closed to '1'. As time passed, the rainfall runoff was getting similar to ratio of pollutants accumulation. The result of a measure of the strength of the linear relationship between observed data and expected data under model was good ($R^2$=0.89). Pollutants runoff loads by volume showed Highway 26.6%, National road 44.8%, Trunk road 35.0% at the MFF20(20% by total runoff). A case of MFF30, pollutants runoff loads by volume showed Highway 40.2%, National road 54.3%, Trunk road 46.8%. According to the results, Initial precipitation basis were Highway MFF30, National road MFF20, Trunk road MFF30 when the Non-Point source control facilities set up.

The Effect of Industrial Waste Water Effluent Charge Reform (수질배출부과금제도 개선 방안 연구)

  • Min, DongKi
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.767-785
    • /
    • 2009
  • This paper studies the effect of industrial waste water effluent charge reform. The goal of the present effluent charge system is to use environmental resources in an efficient way by charging the cost for removing emitted water pollutants. However, the present system is a type of regulation instead of providing economic incentives to the industry. That is, if a firm emits pollutants greater than the limit, it has to pay an amount greater than the cost of cleaning them taking into account the amount of waste water discharged, region, the number of violation and the level of density of pollutants. However, the excessive fees have resulted in the lowest ratio of revenue-to-effluent charge among all environmental charges. The paper estimates the effect of the change in effluent fee and revenue when the present effluent charge system is converted to one that offers economic incentives. The results show that the amount of waste water effluent charge is about four times larger than the estimated environmental cleaning cost. In addition, the results show that by modifying the effluent charge system, the ratio of revenue to effluent charge can be raised.

  • PDF