• Title/Summary/Keyword: Water pipes

Search Result 701, Processing Time 0.024 seconds

2D Numerical Simulations of Bubble Flow in Straight Pipes (직관내 기포의 흐름에 대한 2차원 수치 모의)

  • Lee, Tae Yoon;Nguyen, Van Thinh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.386-390
    • /
    • 2016
  • Water aeration is an effective water treatment process, which involves the injection of air or air-water mixture into water treatment reservoir commonly through pipes. The main purpose of water aeration is to maintain healthy levels of dissolved oxygen (DO), which is the most important water quality factor. The pipes' operating conditions are important for controlling the efficiency and effectiveness of aeration process. Many studies have been conducted on two-phase flows in pipes, however, there are a few studies to deal with small s ale in millimeter. The main objective of this study is to perform 2-dimensional two-phase simulations inside various straight pipes using the computational fluid dynamic (CFD) OpenFOAM (Open source Field Operation And Manipulation) tools to examine the influence of flow patterns on bubble size, which is closely related to DO concentration in a water body. The both flow regimes, laminar and turbulence, have been considered in this study. For turbulence, Reynolds-averaged Navier-Stokes (RANS) has been applied. The coalescence and breakage of bubbles caused by random collisions and turbulent eddies, respectively, are considered in this research. Sauter mean bubble diameter and water velocity are compared against experimental data. The simulation results are in good agreement with the experimental measurements.

  • PDF

Ultrasonic characterization of exhumed cast iron water pipes

  • Groves, Paul;Cascante, Giovanni;Knight, Mark
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.241-262
    • /
    • 2011
  • Cast iron pipe has been used as a water distribution technology in North America since the early nineteenth century. The first cast iron pipes were made of grey cast iron which was succeeded by ductile iron as a pipe material in the 1940s. These different iron alloys have significantly different microstructures which give rise to distinct mechanical properties. Insight into the non-destructive structural condition assessment of aging pipes can be advantageous in developing mitigation strategies for pipe failures. This paper examines the relationship between the small-strain and large-strain properties of exhumed cast iron water pipes. Nondestructive and destructive testing programs were performed on eight pipes varying in age from 40 to 130 years. The experimental program included microstructure evaluation and ultrasonic, tensile, and flexural testing. New applications of frequency domain analysis techniques including Fourier and wavelet transforms of ultrasonic pulse velocity measurements are presented. A low correlation between wave propagation and large-strain measurements was observed. However, the wave velocities were consistently different between ductile and grey cast iron pipes (14% to 18% difference); the ductile iron pipes showed the smaller variation in wave velocities. Thus, the variation of elastic properties for ductile iron was not enough to define a linear correlation because all the measurements were practically concentrated in single cluster of points. The cross-sectional areas of the specimens tested varied as a result of minor manufacturing defects and levels of corrosion. These variations affect the large strain testing results; but, surface defects have limited effect on wave velocities and may also contribute to the low correlations observed. Lamb waves are typically not considered in the evaluation of ultrasonic pulse velocity. However, Lamb waves were found to contribute significantly to the frequency content of the ultrasonic signals possibly resulting in the poor correlations observed. Therefore, correlations between wave velocities and large strain properties obtained using specimens manufactured in the laboratory must be used with caution in the condition assessment of aged water pipes especially for grey cast iron pipes.

A Statistical Methodology for Evaluating the Residual Life of Water Mains (상수관로의 잔존수명 평가를 위한 통계적 방법론)

  • Park, Suwan;Choi, Chang Log;Kim, Jeong Hyun;Bae, Cheol Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.305-313
    • /
    • 2009
  • This paper provides a method for evaluating a residual life of water mains using a proportional hazard model(PHM). The survival time of individual pipe is defined as the elapsed time since installation until a break rate of individual pipe exceeds the Threshold Break Rate. A break rate of an individual pipe is estimated by using the General Pipe Break Model(GPBM). In order to use the GPBM effectively, improvement of the GPBM is presented in this paper by utilizing additional break data that is the cumulative number of pipe break of 0 for the time of installation and adjusting a value of weighting factor(WF). The residual lives and hazard ratios of the case study pipes of which the cumulative number of pipe breaks is more than one is estimated by using the estimated survival function. It is found that the average residual lives of the steel and cast iron pipes are about 25.1 and 21 years, respectively. The hazard rate of the cast iron pipes is found to be higher than the steel pipes until 20 years since installation. However, the hazard rate of the cast iron pipes become lower than the hazard rates of the steel pipes after 20 years since installation.

Coating formation of water supply pipes by inhibitor and water quality improvement effect (부식억제제에 의한 상수도관의 피막 형성 및 수질개선 효과)

  • Lim, Jae-Cheol;Kim, Jin-Keun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.97-106
    • /
    • 2012
  • To investigate the application of corrosion inhibitor on water supply pipes, turbidity, magnitude of corrosion, composition of scale and concentration of metals from an old steel pipe were analysed under inhibitor addition. The concentration of turbidity, iron and copper from the pipes under inhibitor application was 12 ~ 14% of the case which no inhibitor was applied, which suggests the application of inhibitor was very effective for internal corrosion control. In addition, SEM, EDX, XRD and XRF test results showed that application of inhibitor was effective for the decrease of iron concentration and increase of oxygen, phosphorus and calcium concentration, which suggested the existence of protective layer. Therefore, the occurrence of red water will be significantly decreased when inhibitor was applied to the old steel pipes.

Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump (펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰)

  • Heo, Min Woong;Min, Ji Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

Estimation of Willlingness-to-pay of Residents for Rehabilitation of the Existing Water Pipes at Inche (인제군의 상수관로 개량을 위한 주민의 지불의사금액 추정)

  • Lee, Jae Hoon;Jeong, Dong Whan;Shin, Seung Bok;Park, Kyoo Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.385-394
    • /
    • 2007
  • The objective of this study was to estimate social cost on rehabilitation of existing water pipes by investigating the willingness-to-pay (WTP) of residents at INJE County to avoid the loss and inconvenience of transportation and business resulting from the sudden failure and leaks of old water pipes. Contingent valuation method was used through conducting survey to 180 residents in Inche County, with questions of double-bounded dichotomous choice. The resulting WTP of residents at Inche was 7,682 won/month/household. The annual social cost could be estimated as 960 million won, which might be caused by the failure of the old water pipes at INJE County.

Attenuation Characteristics of the Buried Steel Water Pipes (지하매설 유체함입 강파이프의 감쇠특성 규명)

  • Park, K.J.;Kang, W.S.;Kim, Y.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The attenuation of the fundamental non-torsional modes that propagate down buried steel water pipes has been studied. The mode shapes, mode attenuation due to leakage into the surrounding medium and the scattering of the modes as they interact with pipe joints and fittings have been investigated. In the low frequency region the mode predicted to dominate over significant propagation distances approximates a plane wave in the water within pipe. The established acoustic technique used to locate leaks in buried steel water pipes assumes that leak noise propagates as a single non-dispersive mode at a velocity related to the low frequency asymptote of this water borne mode.

  • PDF

A study on the basic experiment of performance criteria for application of pipe bursting method in actual field (Pipe Bursting 공법의 적용성 검토를 위한 주요 성능평가 항목의 기초실험연구)

  • Park, Sangbong;Kim, Kibum;Seo, Jeewon;Park, Sanghyuk;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.435-443
    • /
    • 2018
  • Most of aged water supply pipes have been replaced by the open cut method. However, this method has some limitations because water pipes, in many cases, are buried together with other underground facilities or are buried in the middle of high-traffic roads or in narrow alleyways where boring machines cannot be used. This research developed a pipe bursting device for small diameter pipes that enables pipe replacement without excavating the ground, by the busting of existing buried pipes followed by the traction and insertion of new pipes. As a results of examining the field applicability of the developed device, PE pipes and PVC pipes required the tractive force of 413.65~665.69 kgf and 457.43~791.35 kgf respectively, plus an additional 30 % tractive force per elbow. The proper number of bursting head was demonstrated that the connection of more than 2 heads could secure a stable bending radius of 15D. The developed device can be improved through field experiments involving various pipe types and pipe diameters, as well as presence/absence of elbow, so as to be utilized regardless of diverse variables according to the conditions of the soils surrounding existing pipes.

Effect of leg of fillet on stress distribution in weldments of large steel water pipes (수도용 대형 강관 용접부의 응력분포에 미치는 각장(leg of fillet)의 영향)

  • 김성도;배강열;나석주
    • Journal of Welding and Joining
    • /
    • v.10 no.3
    • /
    • pp.54-62
    • /
    • 1992
  • Large steel water pipes are joined prevalently by bell and method and welded at inside and outside of lapped parts. According to the Korean Standard(KS) for fabrication of water pipes, the weldments are designed to have the length of leg which is same as or larger than the thickness of the pipe. It is recently pointed out that the standard size of weldments is too large, which results in an excessive consumption of material and labor. In this study, several cases of weldments having different sizes were investigated to reduce the length of leg to the effective size. For each case, the analysis of stresses was carried out to evaluate the safety of the welded pipes by using a package program, ANSYS, under the consideration of the loading condition of water pipes which includes the soil pressure on the pipe, the load over the road, and temperature change of the pipe. The results of this study revealed that the weldment which has the length of leg of the size over 0.7*thickness of the pipe could provide a stress level below the yield strength. Especially when the length of leg is 85% of the wall thickness, the maximum equivalent stress is only slightly higher than that of the leg of fillet of the size of 1.0*pipe thickness.

  • PDF

Water pipe deterioration assessment using ANN-Clustering (ANN-Clustering 기법을 이용한 상수관로 노후도 평가 및 분류)

  • Lee, Sleemin;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.959-969
    • /
    • 2018
  • The aging water pipes induce various problems, such as water supply suspension due to breakage, insufficient water pressure, deterioration of water quality, damage by sink holes, and economic losses due to water leaks. However, it is impractical and almost impossible to repair and/or replace all deteriorated water pipes simultaneously. Hence, it is required to quantitatively evaluate the deterioration rate of individual pipes indirect way to determine the rehabilitation order of priority. In this study, ANN(Artificial Neural Network)-Clustering method is suggested as a new approach to assess and assort the water pipes. The proposed method has been applied to a water supply network of YG-county in Jeollanam-do. To assess the applicability of the model, the evaluation results were compared with the results of the Numerical Weighting Method (NWM), which is being currently utilized in practice. The assessment results are depicted in a water pipe map to intuitively grasp the degree of deterioration of the entire pipelines. The application results revealed that the proposed ANN-Clustering models can successfully assess the water pipe deterioration along with the conventional approach of NWM.