• 제목/요약/키워드: Water pipeline

검색결과 383건 처리시간 0.028초

A Galvanic Sensor for Monitoring the External and Internal Corrosion Damage of Buried Pipelines

  • Choi, Yoon-Seok;Kim, Jung-Gu;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.178-190
    • /
    • 2005
  • In order to develop a new corrosion sensor for detecting and monitoring the external and internal corrosion damage of buried pipeline, the electrochemical property of sensors and the correlation of its output to corrosion rate of steel pipe, were evaluated by electrochemical methods in two soils of varying resistivity (5,000 ohm-cm, 10,000 ohm-cm) and synthetic tap water environments. In this paper, two types of galvanic probes were manufactured: copper-pipeline steel (Cu-CS) and stainless steel-pipeline steel (SS-CS). The corrosion behavior in synthetic groundwater and synthetic tap water for the different electrodes was investigated by potentiodynamic test. The comparison of the sensor output and corrosion rates revealed that a linear relationship was found between the probe current and the corrosion rates. In the soil resistivity of $5,000{\Omega}-cm$ and tap water environments, only the Cu-CS probe had a good linear quantitative relationship between the sensor output current and the corrosion rate of pipeline steel. In the case of $10,000{\Omega}-cm$, although the SS-CS probe showed a better linear correlation than that of Cu-CS probe, the Cu-CS probe is more suitable than SS-CS probe due to the high current output.

피압 단순 관로 체제에서의 인버스 임피던스를 이용한 수압기반 유속추정기술 (A pressure based flow velocity estimation technique using inverse impedance for simple pressurized pipeline systems)

  • 이정섭;고동원;최두용;김상현
    • 상하수도학회지
    • /
    • 제36권4호
    • /
    • pp.219-228
    • /
    • 2022
  • In this study, we propose a flow velocity evaluation scheme based on pressure measurement in pressurized pipeline systems. Conservation of mass and momentum equations can be decomposed into mean and perturbation of pressure head and flowrate, which provide the pressure head and flowrate relationship between upstream and donwstream point in pressurized pipeline system. The inverse impedance formulations were derived to address measured pressure at downstream to evaluation of flow velocity or pressure at any point of system. The convolution of response function to pressure head in downstream valve provides the flow velocity response in any point of the simple pipeline system. Simulation comparison between traditional method of characteristics and the proposed method provide good agreements between two distinct approaches.

부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구 (Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis)

  • 황상용;송호봉
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).

GIS 기반 상수도 관망관리시스템 구축의 개선 방안에 관한 연구 (A Study on the Improvement Methods for Water Supply Facility Management System Implementation by GIS)

  • 연상호
    • 한국지리정보학회지
    • /
    • 제3권3호
    • /
    • pp.90-97
    • /
    • 2000
  • 본 연구는 중소도시에서 산재되어 있는 상수도 관망관리를 위하여 GIS의 적용시 개선되어져야 할 중요한 문제점을 파악하여 그 방안을 도출하기 위한 것으로 제천시의 관망도를 중심으로 분석 정리하였다. 이를 위하여 현재의 상수도 업무를 중심으로 관련분야와의 연계방안과 그 모형을 도출하였으며, 기 설치되어 운영하고 있는 상수도 시설물 관리시스템과의 비교를 통하여 문제점을 찾아 그 개선 방안을 제시하였다. 그 연구결과로 GIS에 의한 상수도관망관리시스템 구축에서는 관망시설정보, 누수방지시설정보, 조건에 따른 관망해석의 정보뿐만 아니라 수치지형정보, 도면전산화정보, 관련 수용가별 정보 등과의 연계를 통한 개발적용이 이루어질 때에 더욱 많은 효과를 기대할 수 있었다.

  • PDF

동결온도가 상수도관의 거동에 미치는 영향 (Behavior Characteristics of Water Supply Pipeline Due to Freezing Temperature)

  • 신은철;류병현;강현회;황순갑
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-10
    • /
    • 2014
  • 이 논문에서는 현장모형 실험을 통하여 동결온도에 따른 상수도관의 거동변형특성을 다루었다. 동결 온도 조건에 따라 상수도관에 미치는 동상압력과 Marston-Spangler 이론에 의한 동상 압력은 다소 차이를 나타내는 것을 보이며, Marston-Spangler이론만으로 관에 작용하는 하중을 고려하는 것은 안전측을 벗어날 수도 있다는 것을 염두 해야 한다. 또한 현장모형실험을 통한 상수도관의 변형률은 수치해석결과보다 작은 값을 나타내는 것을 확인하였다.

이변량 감소모델을 적용한 배급수관망에서의 잔류염소농도 예측 및 이의 활용 (Prediction of residual chlorine using two-component second-order decay model in water distribution network)

  • 김영효;권지향;김두일
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.287-297
    • /
    • 2014
  • It is important to predict chlorine decay with different water purification processes and distribution pipeline materials, especially because chlorine decay is in direct relationship with the stability of water quality. The degree of chlorine decay may affect the water quality at the end of the pipeline: it may produce disinfection by-products or cause unpleasant odor and taste. Sand filtrate and dual media filtrate were used as influents in this study, and cast iron (CI), polyvinyl chloride (PVC), and stainless steel (SS) were used as pipeline materials. The results were analyzed via chlorine decay models by comparing the experimental and model parameters. The models were then used to estimate rechlorination time and chlorine decay time. The results indicated that water quality (e.g. organic matter and alkalinity) and pipeline materials were important factors influencing bulk decay and sand filtrate exhibited greater chlorine decay than dual media filtrate. The two-component second-order model was more applicable than the first decay model, and it enabled the estimation of chlorine decay time. These results are expected to provide the basis for modeling chlorine decay of different water purification processes and pipeline materials.

수량화II류이론을 활용한 상수도관로의 안전성 평가 모델 개발 및 적용성 평가 연구 (A Study on the Development and Applicative Estimation of Safety Evaluation Model for Water Supply Pipelines using Quantification Theory Type II)

  • 김기범;신휘수;서지원;구자용
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2016
  • Owing to time and cost constraints, new methods that would make it possible to evaluate the safety of the water supply pipeline in a less time- and cost-consuming manner are urgently needed. In response to this exigency, the present study developed a new statistical model to assess the safety of the water supply pipeline using the quantification theory type II. In this research, the safety of the water supply pipeline was defined as 'a possibility of the pipeline failure'. Quantification analysis was conducted on the qualitative data, such as pipe material, coating, and buried condition. The results of analyses demonstrate that the hit ratio of the quantification function amounted to 77.8% of hit ratio, which was a fair value. In addition, all variables that were included in the quantification function were logically valid and demonstrated statistically significant. According to the results derived from the application of the safety evaluation model, the coefficient of determination ($R^2$) between K-region's water supply pipeline safety and the safety inspection amounted to 0.80. Therefore, these findings provide meaningful insight for the measured values in real applications of the model. The results of the present study can also be meaningfully used in further research on safety evaluation of pipelines, establishing of renewal prioritization, as well as asset management planning of the water supply infrastructure.

상수관로 압력계 최적 위치선정을 위한 데이터기반 시험분석 (Data-based Analysis for Pressure Gauge Optimal Positioning in Water Supply Pipeline)

  • 이호현;홍성택
    • 한국정보통신학회논문지
    • /
    • 제25권6호
    • /
    • pp.834-840
    • /
    • 2021
  • 먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

관로 조사를 위한 오토 인코더 기반 이상 탐지기법에 관한 연구 (A study on the auto encoder-based anomaly detection technique for pipeline inspection)

  • 김관태;이준원
    • 상하수도학회지
    • /
    • 제38권2호
    • /
    • pp.83-93
    • /
    • 2024
  • In this study, we present a sewer pipe inspection technique through a combination of active sonar technology and deep learning algorithms. It is difficult to inspect pipes containing water using conventional CCTV inspection methods, and there are various limitations, so a new approach is needed. In this paper, we introduce a inspection method using active sonar, and apply an auto encoder deep learning model to process sonar data to distinguish between normal and abnormal pipelines. This model underwent training on sonar data from a controlled environment under the assumption of normal pipeline conditions and utilized anomaly detection techniques to identify deviations from established standards. This approach presents a new perspective in pipeline inspection, promising to reduce the time and resources required for sewer system management and to enhance the reliability of pipeline inspections.

하천을 횡단하는 도수관로의 최적 매설구간 선정을 위한 흐름 및 하상변동 수치모의 (Numerical Analysis of Flow and Bed Changes for Selecting Optimized Section of Buried Water Pipeline Crossing the River)

  • 장은경;지운
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1756-1763
    • /
    • 2014
  • 하천을 횡단하는 관로를 매설할 경우 하상변동으로 인해 관로가 드러나는 사고가 발생할 수 있으며 이를 방지하기 위해서는 안전한 매설경로를 분석할 필요가 있다. 본 연구에서는 금강을 횡단하는 도수관로의 안전한 매설구간 선정을 위해 2차원 수치모형을 이용하여 흐름해석 및 하상변동 분석을 수행하였다. 20년 빈도 홍수량을 적용한 모의 결과, 전반적으로 하상이 퇴적되는 것으로 나타났으나 교각의 영향을 받는 구간에서는 관로 매설 깊이 2 m 이상의 침식이 발생하는 것으로 나타났다. 극한 호우 사상에서도 교각 상류와 근접한 부근에서 관로매설 위치까지 침식이 발생하는 것으로 나타났다. 따라서 교각위치에서 상류 약 140 m 까지는 교각의 영향으로 하상침식이 매설된 관로에 영향을 미칠 것으로 예상된다. 상류 150 m 이후에 위치한 관로 횡단경로들은 하상 침식에 대해 상대적으로 안정적일 것으로 판단되어 안전을 고려하여 이를 도수관로 횡단경로의 최적구간으로 선정하였다.