• Title/Summary/Keyword: Water model

Search Result 13,788, Processing Time 0.049 seconds

Zooplankton and Neustonic Microplastics in the Surface Layer of Yeosu Coastal Areas (여수 연안 표층에 출현하는 동물플랑크톤과 미세플라스틱)

  • Kang, Hui Seung;Seo, Min Ho;Yang, Yun Seok;Park, Eun-Ok;Yoon, Yang Ho;Kim, Daejin;Jeong, Hyeon Gyeong;Soh, Ho Young
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.1
    • /
    • pp.11-20
    • /
    • 2018
  • In planktonic ecosystems, the microplastics are considered as a potential food source for the zooplankton. To study a relationship between the zooplankton and the neustonic microplastics, a research experiment was carried out during May in the surface layers of the Yeosu coastal areas including Yeoja Bay, Gamak Bay, Yeosuhae Bay, and Botdol Sea. A neustonic zooplankton net (mesh size $300{\mu}m$; mouth area $30cm{\times}18cm$) was towed from the side of the ship in the event that it would not be affected by waves crashing by the ship at a speed of ca. 2.5 knots. All of the microplastic particles were separated from the zooplankton. The zooplankton and microplastics were appearing in a range of 61 to $763indiv.m^{-3}$ and 0.0047 to $0.3471particle\;m^{-2}$, respectively. It was noted that the Acartia omorii, Paracalanus parvus s. l., Labidocera euchaeta, A. hongi, decapod larvae, and cirriped larvae were predominantly seen in the experiment. For verifying relationships between zooplankton and environmental factors in addition to microplastics, a model redundancy analysis (RDA) was performed. The zooplankton were divided into two groups on the basis of feeding types (i.e. particle feeders, and carnivores), and the associated zooplankton larvae were also separately considered. A review of the additional environmental factors such as water temperature, salinity, turbidity, chlorophyll-${\alpha}$ concentration, diatom density, and dinoflagellate density were also contained in the analysis. The results showed that a noted zooplankton abundance had no close relation with the occurring number of microplastic particles, but rather was significantly related with other noted environmental factors such as temperature, salinity, turbidity, and chlorophyll-${\alpha}$ concentration. This fact implies that most zooplankton can feed themselves as a unit, by selecting the most likely available nutritious foods, rather than microplastics under the circumstance of food-richness areas, such what food resources are available as in the location of coastal waters.

Effects of Heat Treatment of Three Animal by-products on Ruminal Degradation Characteristics and Intestinal Availability of Crude Protein (동물성 부산물 사료 세 종류에 대한 열처리가 조단백질의 반추위내 분해특성 및 하부장기내 이용성에 미치는 영향)

  • Moon, Y.H.;Lee, S.C.;Kim, B.K.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.105-112
    • /
    • 2002
  • In order to investigate the effects of heat treatment of three animal by-products(feather meal, tallow meal, viscera meal) on in situ ruminal degradation characteristics and gastrointestinal availability of dietary crude protein(CP), three ruminally and duodenally cannulated dry Holstein cows were employed. Cows were fed a diet containing 60% concentrate and 40% orchard grass hay, and had free access to water and mineral block. Experimental feeds were processed for 4 hr at 149$^{\circ}C$ in a forced-air oven, and were passed through a 1-mm screen. Degradation kinetics of feed protein in the rumen were fitted to an exponential type model, and intestinal availability was estimated by the mobile nylon bag technique. Effective CP degradabilities in the rumen for feather meal, tallow meal and viscera meal were 30.2%, 75.0% and 56.4% at 5% passage rate per hour(k=0.05), respectively. In addition, heat treatment increased effective ruminal CP degradability on feather meal and viscera meal treatments, whereas decreased in tallow meal treatment(P$<$0.05). Gastrointestinal CP disappearances of feather meal, tallow meal and viscera meal were 56.2%, 18.6%, and 37.9%, respectively. In addition, heat treatment decreased the gastrointestinal CP disappearance on feather meal and viscera meal treatment, but increased in tallow meal treatment(P$<$0.05). Intestinal availability of rumen undegradable protein(A-UDP) was 80.4% for feather meal, 83.8% for tallow meal and 86.9% for viscera meal. In addition, heat treatment increased A-UDP on feather meal and tallow meal treatment, 94.0% and 91.3%, respectively, but decreased on viscera meal treatment, 76.5%(P$<$0.05).

The Behaviour of Fishes to the Traps and Their Catch Ability (통발에 대한 어류의 행동과 어획성능에 관한 연구)

  • KO Kwan-Soh;KIM Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.15-23
    • /
    • 1984
  • Difference of the entering and the escaping behaviour of shrimp(Palaemon pacificus) to the model traps were observed in accordance with netting materials, baits, type of traps and slope of flapper, and gathering responses were also investigated on the odour of bait extracts in the aquarium as the preliminary test. In order to investigate the difference in catch according to type and structure of traps those designated from A to E were made of iron frames and nettings. The type A was a conical shape with two entrances at its both sides and the others were square piller shape with one entrance at their upper surface(type B) or two entrance at their both ends(type C, D and E). However th type D and E were connected with flapper and the thye E was made by attaching iron frames of same height under the type D. The traps were prepared 10 each and so a total of 50 traps were used in the experiment at sea. The main species caught was Charybdis japonica, but Astroconger myriaster was also caught fairly. The catches of these species were significant in difference between the types of traps. That is, Charybdis japonica was caught more in type A, C and D than others and less in type B and E, and Astroconger myriaster was caught more in type A and D and less in type B and E. However the catch of Astroconger myriaster in type C, even if less than that in type A showed no significant difference with the other traps. The total catch of Charybdis japonica and Astroconger myriaster was almost same in order with the catch of Charybdis japonica. The type B and E seemed to be difficult in entering of fishes into them. However, the type A and C seemed to be easy not only in entering, but also in escaping. Especially, the type C showed more escaping. On the other hand, the type D seemed to be not so easy in entering of fishes as type A and C, but very difficult in escaping. Consequently, the escaping of fishes from the traps seemed to be more difficult in conical traps than any other traps. The catches might be influenced by the bait with bag compare to without bag and also the immersed time of traps into water for fishing.

  • PDF

Effects and Improvement of Carbon Reduction by Greenspace Establishment in Riparian Zones (수변구역 조성녹지의 탄소저감 효과 및 증진방안)

  • Jo, Hyun-Kil;Park, Hye-Mi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.6
    • /
    • pp.16-24
    • /
    • 2015
  • This study quantified storage and annual uptake of carbon for riparian greenspaces established in watersheds of four major rivers in South Korea and explored desirable strategies to improve carbon reduction effects of riparian greenspaces. Greenspace structure and planting technique in the 40 study sites sampled were represented by single-layered planting of small trees in low density, with stem diameter at breast height of $6.9{\pm}0.2cm$ and planting density of $10.4{\pm}0.8trees/100m^2$ on average. Storage and annual uptake of carbon per unit area by planted trees averaged $8.2{\pm}0.5t/ha$ and $1.7{\pm}0.1t/ha/yr$, respectively, increasing as planting density got higher. Mean organic matter and carbon storage in soils were $1.4{\pm}0.1%$ and $26.4{\pm}1.5t/ha$, respectively. Planted trees and soils per ha stored the amount of carbon emitted from gasoline consumption of about 61 kL, and the trees per ha annually offset carbon emissions from gasoline use of about 3 kL. These carbon reduction effects are associated with tree growth over five years to fewer than 10 years after planting, and predicted to become much greater as the planted trees grow. This study simulated changes in annual carbon uptake by tree growth over future 30 years for typical planting models selected as different from the planting technique in the study sites. The simulation revealed that cumulative annual carbon uptake for a multilayered and grouped ecological planting model with both larger tree size and higher planting density was approximately 1.9 times greater 10 years after planting and 1.5 times greater 30 years after than that in the study sites. Strategies to improve carbon reduction effects of riparian greenspaces suggest multilayered and grouped planting mixed with relatively large trees, middle/high density planting of native species mixed with fast-growing trees, and securing the soil environment favorable for normal growth of planting tree species. The research findings are expected to be useful as practical guidelines to improve the role of a carbon uptake source, in addition to water quality conservation and wildlife inhabitation, in implementing riparian greenspace projects under the beginning stage.

Effects of Natural Wetland in Reducing Nutrient Loadings from Rice Culture - Free-Range Ducks (RCFD) Paddy fields in Korea (오리농업재배 소유역내 자연습지가 오리농업시 유출되는 영양염류 부하량 저감에 미치는 영향)

  • Ko, Jee-Yeon;Lee, Jae-Saeng;Jung, Ki-Youl;Choi, Young-Dae;Yun, Eul-Soo;Woo, Koan-Sik;Seo, Myung-Chul;Nam, Min-hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.4
    • /
    • pp.249-256
    • /
    • 2009
  • The amount of nutrients from the effluents of rice culture - free-range ducks (RCFD) paddy fields and the effects of natural wetlands located at downstream of RCFD on water quality and aquatic plants was evaluated. This was carried out in a 61.9 ha paddy fields in Ulsan, Gyeongnam, where downstream is a 5.9 ha natural wetland, 61% of which was covered with well-developed aquatic plants. The amounts of T-N and T-P in the effluent from paddy field with RCFD were 13.7 and $2.5kg\;ha^{-1}$, respectively, which is 1.2~2.5 times higher than those observed in conventional rice culture practice. The amount of runoff from the RCFD area, calculated using the revised TANK model, was $543mm\;ha^{-1}$ with 808 kg of T-N and 130 kg of T-P during rice cultivation period. The dominant aquatic plants in the wetland includes Phragmites communis, Zizania latifolia, Persicaria thunbergii. etc. The nutrient contents of the aquatic plants which amounted to 761 kg of T-N and 103 kg of T-P were almost equivalent to 94% and 79% of the T-N and T-P in RCFD and CRC effluent. Therefore, the use and maintenance of wetlands in RCFDs area could be a good solution to management the non-point pollution from duck feces in RCFD paddy fields.

Estimation of Surface Solar Radiation using Ground-based Remote Sensing Data on the Seoul Metropolitan Area (수도권지역의 지상기반 원격탐사자료를 이용한 지표면 태양에너지 산출)

  • Jee, Joon-Bum;Min, Jae-Sik;Lee, Hankyung;Chae, Jung-Hoon;Kim, Sangil
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.228-240
    • /
    • 2018
  • Solar energy is calculated using meteorological (14 station), ceilometer (2 station) and microwave radiometer (MWR, 7 station)) data observed from the Weather Information Service Engine (WISE) on the Seoul metropolitan area. The cloud optical thickness and the cloud fraction are calculated using the back-scattering coefficient (BSC) of the ceilometer and liquid water path of the MWR. The solar energy on the surface is calculated using solar radiation model with cloud fraction from the ceilometer and the MWR. The estimated solar energy is underestimated compared to observations both at Jungnang and Gwanghwamun stations. In linear regression analysis, the slope is less than 0.8 and the bias is negative which is less than $-20W/m^2$. The estimated solar energy using MWR is more improved (i.e., deterministic coefficient (average $R^2=0.8$) and Root Mean Square Error (average $RMSE=110W/m^2$)) than when using ceilometer. The monthly cloud fraction and solar energy calculated by ceilometer is greater than 0.09 and lower than $50W/m^2$ compared to MWR. While there is a difference depending on the locations, RMSE of estimated solar radiation is large over $50W/m^2$ in July and September compared to other months. As a result, the estimation of a daily accumulated solar radiation shows the highest correlation at Gwanghwamun ($R^2=0.80$, RMSE=2.87 MJ/day) station and the lowest correlation at Gooro ($R^2=0.63$, RMSE=4.77 MJ/day) station.

Correlations between the Stream Morphological Characteristics and the Hydraulic Geometry Characteristics for the Basin (유역(流域)의 하천형태학적(河川形態學的) 특성(特性)과 수리기하학적(水理幾何學的) 특성(特性)과의 상관성(相關性))

  • Ahn, Sang Jin;Yoon, Yong Nam;Kang, Kwan Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.1-17
    • /
    • 1982
  • The stream morphological characteristics of a river basin has a close correlation with the hydrological and hydraulic characteristics of the basin. In this study the correlations of flow duration and Hydraulic geometry with the stream morphological characteristics as well as the correlation between flow duration and hydraulic geometry were analyzed bases on the data for the Geum River basin. The purpose of this study was to provide the necessary informations for water utilization projects at ungauged locations along the river course. First of all, the stream morphological characteristics was analyzed based on the Horton's three laws on the morphology of a stream that is, the law of stream number, the law of average stream length and the law of average stream slope. As is the case for majority of the rivers it was found that the Geum River basin was well developed according to the Horton's laws. High correlations were also found between the basin characteristics and the channel characteristics. The flow duration curves obtained with the daily stream flow data of 10~90% frequency of occurences at the five stage gauging stations in the Geum River could, in general, be expressed as an exponential functional relationship. The concept of proportional stream ordering system was employed to describe continuously the longitudinal variation of the stream morphological characteristics, and the mathematical model was formulated for the discharge-frequency-proportional stream order relationship. With the morphological characteristics as a common parameter the relationships with flow duration, drainage area were established in mathematical expressions, respectively.

  • PDF

Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer (해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정)

  • Lee, Jae-Seong;Kim, Kee-Hyun;Yu, Jun;Lee, Pil-Yong;Jung, Rae-Hong;Lee, Wong-Chan;Han, Jung-Jee;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.64-72
    • /
    • 2004
  • We measured the vertical profiles of $O_2$, H$_2$S, and pH in sediment pore water beneath marine cage fish farms using a microsensor with a 25 ${\mu}{\textrm}{m}$ sensor tip size. The sediments are characterized by high organic material load. The oxygen consumption, hydrogen sulfide oxidation, and sulfate reduction rates in the microzonations (derived from the vertical distribution of chemical species concentration) were estimated by adapting a simple one-dimensional diffusion-reaction model. The oxygen penetration depth was 0.75 mm. The oxic microzonations were divided into upper and lower layers. Due to hydrogen sulfide oxidation within the oxic zone, the oxygen consumption rate was higher in the lower layer. The total oxygen consumption rate integrated with reaction zone depth was estimated to be 0.092 $\mu$mol $O_2$cm$^{-2}$ hr$^{-1}$ . The total hydrogen sulfide oxidation rate occurring within 0.7 mm thickness was estimated to be 0.030 $\mu$mo1 H$_2$S cm$^{-2}$ hr$^{-1}$ , and its turnover time in the oxic sediment layer was estimated to be about 2 minutes. This suggests that hydrogen sulfide was oxidized by both chemical and microbial processes in this zone. The molar consumption ratio, calculated to be 0.84, indicates that either other electron accepters exit on hydrogen sulfide oxidation, or elemental sulfur precipitation occurs near the $O_2$- H$_2$S interface. Total sulfate reduction flux was estimated to be 0.029 $\mu$mol cm$^{-2}$ hr$^{-1}$ , which accounted for more than 60% of total $O_2$ consumption flux. This result implied that the degradation of organic matter in the anoxic layer was larger than in the oxic layer.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Characteristics of Natural Arsenic Contamination in Groundwater and Its Occurrences (자연적 지하수 비소오염의 국내외 산출특성)

  • Ahn Joo Sung;Ko Kyung-Seok;Lee Jin-Soo;Kim Ju-Yong
    • Economic and Environmental Geology
    • /
    • v.38 no.5 s.174
    • /
    • pp.547-561
    • /
    • 2005
  • General characteristics of groundwater contamination by As were reviewed with several recent researches, and its occurrence in groundwater of Korea was investigated based on a ffw previous studies and a groundwater quality survey in Nonsan and Geumsan areas. In Bangladesh, which has been known as the most serious arsenic calamity country, about $28\%$ of the shallow groundwaters exceeded the Bangladesh drinking water standard, $50{\mu}g/L$, and it was estimated that about 28 million people were exposed to concentrations greater than the standard. Groundwater was characterized by circum-neutral pH with a moderate to strong reducing conditions. Low concentrations of $SO_4^{2-}$ and $NO_3^-$, and high contents of dissolved organic carbon (DOC) and $NH_4^+$ were typical chemical characteristics. Total As concentrations were enriched in the Holocene alluvial aquifers with a dominance of As(III) species. It was generally agreed that reductive dissolution of Fe oxyhydroxides was the main mechanism for the release of As into groundwater coupling with the presence of organic matters and microbial activities as principal factors. A new model has also been suggested to explain how arsenic can naturally contaminate groundwaters far from the ultimate source with transport of As by active tectonic uplift and glaciatiion during Pleistocene, chemical weathering and deposition, and microbial reaction processes. In Korea, it has not been reported to be so serious As contamination, and from the national groundwater quality monitoring survey, only about $1\%$ of grounwaters have concentrations higher than $10{\mu}g/:L.$ However, it was revealed that $19.3\%$ of mineral waters, and $7\%$ of tube-well waters from Nonsan and Geumsan areas contained As concentrations above $10{\mu}g/:L.$. Also, percentages exceeding this value during detailed groundwater quality surveys were $36\%\;and\;22\%$ from Jeonnam and Ulsan areas, respectively, indicating As enrichment possibly by geological factors and local mineralization. Further systematic researches need to proceed in areas potential to As contamination such as mineralized, metasedimentary rock-based, alluvial, and acid sulfate soil areas. Prior to that, it is required to understand various geochemical and microbial processes, and groundwater flow characteristics affecting the behavior of As.