• Title/Summary/Keyword: Water mass analysis

Search Result 1,182, Processing Time 0.03 seconds

Analysis of Polycyclic Aromatic Hydrocarbons in Agricultural Waterways in Chungbuk and Gyeongbuk Provinces in Korea

  • Kim, Leesun;Lee, Jong-Hwa;Kim, Jeong-Han;Lee, Sung-Eun
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.3
    • /
    • pp.345-351
    • /
    • 2018
  • An efficient, quick and low-cost extraction and clean up method for the determination of 14 polycyclic aromatic hydrocarbons (PAHs) in the agricultural water samples was optimized using gas chromatography-tandem mass spectrometry (GC-MS/MS). The extraction of the target compounds in water sample was carried out with acetonitrile, followed by partitioning promoted by the addition of salt. As a clean-up procedure, dispersive solid phase extraction was employed to purify the analytes of interest for GC-MS/MS analysis. This method was successfully applied for the quantification of PAHs in real water samples collected for the purpose of monitoring from the waterways located in Chungbuk (15 sites) and Gyeongbuk (6 sites), S. Korea. Phenanthrene (0.54 to $2.53{\mu}gL^{-1}$) was detected in all the water samples collected from both the sites. Fluoranthene was detected in the water samples collected from the two sites in Gyeongbuk province, but other PAHs were not determined in these water sampling sites. Based on these results, the determined PAHs were conducted using an environmental risk assessment. The risk characterization ratios (RCRs) for phenanthrene ranged from 0.37 to 3.21. These RCR values referred to as risk was not controlled because RCR values of some sites were greater than 1. In conclusion, it is proposed that the optimized method in combination with GC-MS/MS could be successfully employed for the determination of PAHs in any environmental samples including water samples.

Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture (흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석)

  • Won, Seung-Ho;Park, Sang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.

Analysis of Thermodynamic Design Data for Heating of Double - Effect Solar Absorption System using LiBr - water and Ethylene Glycol Mixture (에틸렌글리콜 혼합액을 사용하고, 태양열을 보조열원으로 하는 이중효용 흡수식 시스템의 난방 특성해석)

  • Won, S.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.51-61
    • /
    • 2002
  • Analysis of thermodynamic design data of double effect solar absorption heat pump system for heating has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data. enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture (H2O: CHO ratio 10:1 by mole) by computer simulation. The obtained results, COP and mass flow ratio of the water-lithium bromide-ethylene glycol system, are compared with data for the water-Libr pair solution.

An Analysis of First Flush Phenomenon of 3 Catchment area in Lake Sihwa Watershed during Rainfall-Runoff Events (강우유출수 영향에 따른 시화호 소유역별 유입하천의 오염물질 초기유출현상 분석)

  • Kim, Sea-Won;Oh, Jong-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.475-485
    • /
    • 2011
  • Lake Sihwa has a very unique watershed environment, surrounded by industrial, urban and rural catchment area with different land use. The first flush phenomenon was investigated in 3 catchment area. 4TG, representing the industrial area, shows rapid discharges of highly concentrated pollutants during the early stages of a storm and it is indicating a strong first flush effect. At AS, representing the urban area, the pollutant concentration reached its peak approximately 2~3 hours after the start of storm, which is a strong first flush effect did not appear. JJB and MS represent the rural areas, the PEMC analysis results suggest that highly concentrated pollutants were discharged during the middle and latter stages of a storm, instead of early pollutant runoff due to the effects of rainwater runoff.

The Analysis of 1,4-Dioxane in Water Sample by Gas Chromatograph/Mass Spectrometer and Risk Assessment (기체크로마토그래프/질량분석계에 의한 물시료 중 1,4-dioxane의 분석 및 위해성 평가)

  • 홍지은;표희수;박송자
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.3
    • /
    • pp.219-224
    • /
    • 2003
  • 1,4-Dioxane is used as a solvent for lacquers, paints, varnish removers, dye baths and printing compositions. And it is also used for detergent preparations, cosmetics, deodorants and fumigants. A method is described for the determination of 1,4-dioxane in water samples by GC/MS. The extraction recoveries were studied for some solvents and solvent volume ratio were investigated using r-butyl methyl ether (MTBE). Optimum condition was obtained by the liquid-liquid extraction using the 10 mL of MTBE for 10 mL of water. Method detection limit of 1,4-dioxane in the 20 mL of water samples was 0.05 ng/mL. It could be determined in the range of 0.24∼240 ng/mL in treated water, and in the range of 0.69∼81.9 ng/mL in raw water, respectively. Risk assessments with 1,4-dioxane exposure by drinking water ingestion were carried out. Based on the results of analysis, chronic daily intake of 1,4-dioxane was 2.22${\times}$10$\^$-4/ mg/kg/day and excess cancer risk was calcu-lated to be 2.44${\times}$10$\^$-6/.

Selection of Optimum Support based on Rock Mass Classification and Monitoring Results at NATM Tunnel in Hard Rock (경암지반 NATM 터널에서 암반분류 및 계측에 의한 최적지보공 선정에 관한 연구)

  • 김영근;장정범;정한중
    • Tunnel and Underground Space
    • /
    • v.6 no.3
    • /
    • pp.197-208
    • /
    • 1996
  • Due to the constraints in pre site-investigation for tunnel, it is essential to redesign the support structures suitable for rock mass conditions such as rock strength, ground water and discontinuity conditions for safe tunnel construction. For the selection of optimum support, it is very important to carry out the rock mass classification and in-situ measurement in tunnelling. In this paper, in a mountain tunnel designed by NATM in hard rock, the selectable system for optimum support has been studied. The tunnel is situated at Chun-an in Kyungbu highspeed railway line with 2 lanes over a length of 4, 020 m and a diameter of 15 m. The tunnel was constructed by drill & blasting method and long bench cut method, designed five types of standard support patterns according to rock mass conditions. In this tunnel, face mapping based on image processing of tunnel face and rock mass classification by RMR carried out for the quantitative evaluation of the characteristics of rock mass and compared with rock mass classes in design. Also, in-situ measurement of convergence and crown settlement conducted about 30 m interval, assessed the stability of tunnel from the analysis of monitoring data. Through the results of rock mass classification and in-situ measurement in several sections, the design of supports were modified for the safe and economic tunnelling.

  • PDF

Characteristics of Water Temperature and Salinity in the Bottol Bada, Yeosu during Summer in 2010 (2010년 하계 보돌바다의 수온과 염분 특성)

  • Cho, Eun-Seob
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.301-306
    • /
    • 2011
  • This study was determined to analysis the characteristics of water mass in the Bottol Bada, Yeosu in August, 2010 based on the data from the distribution of water temperature and salinity. Sampling was carried out a total of three times (i.e. July 29, August 13, and August 30, 2010) and performed at three stations. Observation was done during the period of time 10:00-15:00, indicating the decreasing tidal height and turn of tide. In July 29, thermocline was found at 4 m in St. 1, but the stratification did not observe in August 13 and August 30. The remarkable water temperature between surface and bottom was found in St. 2 and St. 3, whereas St. 1 did not find. A particular finding during this study showed a cold water mass at bottom layer from St. 2 and St. 3, which was first occurred in July 29 and persisted in August 30 without any of destruction. Water temperature had a remarkable fluctuation between surface and bottom, whereas salinity had a unique in St. 1. St. 2 and St. 3 showed the increasing salinity according to water depth in August 13 and August 30. Transparency had considerable fluctuations in St. 1 and St. 3 depending to sampling date, but St. 2 did not fluctuate. Consequently, the Bottol Bada had a significantly different water mass between inner and outer waters. Furthermore, strong irradiance and weak wind play an important role in developing the stratification between surface and bottom, in particular the introduction of offshore waters contribute to highly developing the stratification in the Bottol Bada during the period of August in 2010.

Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus (냉이온수기 냉각시스템에 관한 열유동 해석)

  • Jeon, Seong-Oh;Lee, Sang-Jun;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

A Study on the Development of Water Quality Forecasting System in Upstream of Paldangdam (팔당댐 상류의 수질예보시스템 개발에 관한 연구)

  • Choi, Nam-Jeong;Seo, Il-Won;Kim, Young-Han;Lee, Myong-Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1387-1391
    • /
    • 2007
  • In this study, water quality prediction that is necessary to water quality forecasting system is performed using 2-D river analysis models RMA-2 and RAM4. RAM4 is suitable to water quality forecasting system cause it is possible to put in the pollutants as a mass type boundary condition. Instant injections of pollutants at Yongdamdaegyo Bridge in Namhangang River are simulated and the behavior of pollutant cloud is observed. The effects of water quality accident to Paldang 2 water intake plants in Paldangho Lake is analyzed with time variation. And extra flow simulation is performed for mitigation of pollution. Several cases of water quality forecasting system at home and abroad are investigated and the direction of water quality forecasting system is presented.

  • PDF