• Title/Summary/Keyword: Water mass

Search Result 3,696, Processing Time 0.03 seconds

A report on the mass summer mortalities of the farmed Pacific oysters, Crassostrea gigas and Bay scallops Argopecten irradians in the local waters of Goseong Bay, Korea

  • Han, Jong Cheol;Jo, Qtae;Park, Young Cheol;Park, Tae Gyu;Lee, Deok Chan;Cho, Kee-Chae
    • The Korean Journal of Malacology
    • /
    • v.29 no.3
    • /
    • pp.239-244
    • /
    • 2013
  • Mass mortalities of farmed shellfish, mostly in summer season, thus named mass summer mortalities, have been a global issue in shellfish aquaculture. The 2013 mass summer mortalities in the confined waters of Goseong Bay, Goseong, Korea were quite a unique and intensive for two farmed species, the Pacific oysters, Crassostrea gigas, and bay scallops, Argopecten irradians. The mortalities were progressive from the bottom of the suspended oysters and caged scallops in the waters, reaching up to 80% for the oyster and 95% for the scallop in about 20 days after the first occurrence, early August, 2013. We monitored a wide range of environmental factors, including water temperature, dissolved oxygen (DO), salinity, turbidity, acidity (pH), organic and inorganic matters, chemical oxygen demand (COD), suspected pathogenic agent, and phytoplankton composition throughout the water column where the two species were suspended or caged. Our survey concluded that the hypoxia or anoxia might be a major cause of the mortalities. Here, we detailed the mortalities and ways to arrive at the conclusion.

Influence of NCG Charged Mass on the Thermal Performance of VCHP with Screen Mesh Wick (스크린메쉬형 VCHP에서 NCG량에 따른 열전달 성능실험)

  • Park, Young-Sik;Chung, Kyung-Taek;Suh, Jeong-Se
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.689-695
    • /
    • 2008
  • Experimental study has been performed to investigate the influence of non-condensible gas(NCG) charged mass on the thermal performance of a variable conductance heat pipe(VCHP) with screen mesh wick. The VCHP is furnished by screen mesh number 200 for the pipe outer diameter of 12.7mm and the pipe length of 500 mm. The VCHP is filled with water as working fluid of 4.8g and nitrogen as NCG and has evaporator, condenser and adiabatic section, respectively. For the results from experiment, it is found that, for the same charged mass of working fluid, the overall wall temperatures of heat pipe grows up with increasing NCG charged mass. The variation of operating temperature of VCHP reduces with increasing NCG mass. In addition, the profile of axial wall temperature distribution is presented for heat transport capacity of heat pipe, the temperature of cooling water of condenser, inclination angle, and operating temperature.

Effect of Rock Mass Properties on Coupled Thermo-Hydro-Mechanical Responses at Near-Field Rock Mass in a Heater Test - A Benchmark Sensitivity Study of the Kamaishi Mine Experiment in Japan

  • Hwajung Yoo;Jeonghwan Yoon;Ki-Bok Min
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.23-41
    • /
    • 2023
  • Coupled thermo-hydraulic-mechanical (THM) processes are essential for the long-term performance of deep geological disposal of high-level radioactive waste. In this study, a numerical sensitivity analysis was performed to analyze the effect of rock properties on THM responses after the execution of the heater test at the Kamaishi mine in Japan. The TOUGH-FLAC simulator was applied for the numerical simulation assuming a continuum model for coupled THM analysis. The rock properties included in the sensitivity study were the Young's modulus, permeability, thermal conductivity, and thermal expansion coefficients of crystalline rock, rock salt, and clay. The responses, i.e., temperature, water content, displacement, and stress, were measured at monitoring points in the buffer and near-field rock mass during the simulations. The thermal conductivity had an overarching impact on THM responses. The influence of Young's modulus was evident in the mechanical behavior, whereas that of permeability was noticed through the change in the temperature and water content. The difference in the THM responses of the three rock type models implies the importance of the appropriate characterization of rock mass properties with regard to the performance assessment of the deep geological disposal of high-level radioactive waste.

Water Mass Distribution and Currents in the Vicinity of the Hupo Bank in Summer 2010 (2010년 하계 후포퇴 근해의 수괴분포와 해류)

  • Lee, Jae Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.1
    • /
    • pp.61-73
    • /
    • 2016
  • Water mass distribution and currents were investigated off the east coast of Korea near the Hupo Bank using the CTD and ADCP data from June to August 2010. The typical water masses were: (1) Tsushima Surface Water (TSW) from the East Korean Warm Current (EKWC) in the surface layer, (2) a shallow thermocline at 20-30 m depth, (3) Tsushima Middle Water (TMW) of high salinity (>34.2) below the pycnocline, (4) North Korean Cold Water (NKCW) of low salinity (<34.05) and low temperature (<4°C) in the lower layer. In June, a double eddy was observed in which a cold filament intruded cyclonically from the south around a pre-existing cold-core eddy. A burst of strong southward current was recorded in mid-August due to a warm filament from the meandering EKWC. Current in the N-S direction was predominant due to topographic effects, and the direction of the northward EKWC was frequently reversed in its direction due to the eddy-filament activity, whereas the influence of the wind was not noticeable. The vertical structure of the current was of a two-layer system, with the northward EKWC in the upper layer and weak southward flows corresponding to the North Korean Cold Current (NKCC) in the deeper layer.

Incremental extended finite element method for thermal cracking of mass concrete at early ages

  • Zhu, Zhenyang;Zhang, Guoxin;Liu, Yi;Wang, Zhenhong
    • Structural Engineering and Mechanics
    • /
    • v.69 no.1
    • /
    • pp.33-42
    • /
    • 2019
  • Thermal cracks are cracks that commonly form at early ages in mass concrete. During the concrete pouring process, the elastic modulus changes continuously. This requires the time domain to be divided into several steps in order to solve for the temperature, stress, and displacement of the concrete. Numerical simulations of thermal crack propagation in concrete are more difficult at early ages. To solve this problem, this study divides crack propagation in concrete at early ages into two cases: the case in which cracks do not propagate but the elastic modulus of the concrete changes and the case in which cracks propagate at a certain time. This paper provides computational models for these two cases by integrating the characteristics of the extended finite element algorithm, compiles the corresponding computational programs, and verifies the accuracy of the proposed model using numerical comparisons. The model presented in this paper has the advantages of high computational accuracy and stable results in resolving thermal cracking and its propagation in concrete at early ages.

Characteristics of Water Temperature and Salinity in the Bottol Bada, Yeosu during Summer in 2010 (2010년 하계 보돌바다의 수온과 염분 특성)

  • Cho, Eun-Seob
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.301-306
    • /
    • 2011
  • This study was determined to analysis the characteristics of water mass in the Bottol Bada, Yeosu in August, 2010 based on the data from the distribution of water temperature and salinity. Sampling was carried out a total of three times (i.e. July 29, August 13, and August 30, 2010) and performed at three stations. Observation was done during the period of time 10:00-15:00, indicating the decreasing tidal height and turn of tide. In July 29, thermocline was found at 4 m in St. 1, but the stratification did not observe in August 13 and August 30. The remarkable water temperature between surface and bottom was found in St. 2 and St. 3, whereas St. 1 did not find. A particular finding during this study showed a cold water mass at bottom layer from St. 2 and St. 3, which was first occurred in July 29 and persisted in August 30 without any of destruction. Water temperature had a remarkable fluctuation between surface and bottom, whereas salinity had a unique in St. 1. St. 2 and St. 3 showed the increasing salinity according to water depth in August 13 and August 30. Transparency had considerable fluctuations in St. 1 and St. 3 depending to sampling date, but St. 2 did not fluctuate. Consequently, the Bottol Bada had a significantly different water mass between inner and outer waters. Furthermore, strong irradiance and weak wind play an important role in developing the stratification between surface and bottom, in particular the introduction of offshore waters contribute to highly developing the stratification in the Bottol Bada during the period of August in 2010.

Determination of benzophenone in water, soil and sediment by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기에 의한 수질, 토양 및 저질 시료중의 benzophenone 분석법에 관한 연구)

  • Jeon, Hee Kyung;Choi, Hae Yeon;Ryu, Jae-Chun
    • Analytical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.147-153
    • /
    • 2005
  • Benzophenone (BP) which is one of endocrine disrupting chemicals is suspected to contaminate waters (river, lake and industrial drainage) and soils (ground soil and sediment). Analytical method for determination of BP in soil and water was developed by gas chromatography/mass spectrometry. Water sample (100 mL) was extracted with n-hexane, and soil (10 g) was extracted with methanol and n-hexane. Recovery for BP was >71.4% in water and 86.5-94.7% in soil with coefficient variation of less than 19.8%. Calibration curves showed a good linearity ($r^2$ >0.998). In water, soil and sediment collected at nation-wide sites, BP was detected at 5 sites among 43 water sites at the concentration range of 30-200 ng/L. No BP was found in the soil and sediment samples. It is suggested that this method will be useful to the determination of BP in the environmental matrices such as waters, soils and sediments in minute quantities.

Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (II) - Exergy Analysis for Working Fluids of R245fa and Water - (선박용 디젤엔진의 배기가스 열회수 시스템 (II) - R245fa 및 Water 의 작동유체에 대한 엑서지 분석 -)

  • Choi, Byung-Chul;Kim, Young-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.593-600
    • /
    • 2012
  • The exergy characteristics for R245fa and water working fluids have been analyzed for an electric generation system utilizing the Rankine cycle to recover heat from the wasted exhaust gas from a diesel engine used for the propulsion of a large ship. The theoretical calculation results showed that the efficiencies of exergy and system exergy improved as the turbine inlet pressure increased for R245fa at a fixed mass flow rate. Furthermore, the exergy destruction rates of the condenser and evaporator were relatively larger than those in other components. The exergy efficiency of the system increased with increasing mass flow rate. For a water working fluid, although the exergy destruction rate of the evaporator was similar to that for R245fa, the exergy loss rate varied significantly in response to variations in the pressure and mass flow rates at the turbine inlet.

Water Mass Stability of Deep Ocean Water in the East Sea (동해 심층수의 수괴 안정성)

  • Moon D.S.;Jung D.H.;Shin P.K.;Kim H.J.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.285-289
    • /
    • 2004
  • Oceanographic observation and qualitative analysis for deep ocean water in the East Sea were carried out from January 2003 to January 2004, in order to understand the characteristics of deep sea water in the East Sea. Temporal and spatial variation of water masses were discussed from survey of the study area including the coastal sea of Kwangwon province in where the polar front mixing cold and warm water masses were formed. On the basis of the vertical profiles of temperature, salinity and dissolved oxygen, water masses in the study area were divided into 5 major groups; (1) Low Saline Surface Water (LSSW) (2) Tsushima Surface water (TSW) (3) Tsushima Middle Water (TMW) (4) North Korea Cold Water (NKCW) and (5) East Sea Proper Water (ESPW). In winter, surface water in coastal sea of Kwangwaan Kosung region were dominated by North Korean Cold Water (NKCW). As Tsushima warm current were enforced in summer, various water masses were vertically emerged in study area, in order of TSW, TMW, NKCW and ESPW. It is highly possible that the LSSW which occurred at surface water of september is originated from influx of fresh water due to the seasonal rainy spell. Nevertheless water masses existed within surface water were seasonally varied, water quality characteristics of East Sea Proper Water (ESPW) under 300 m did not changed all the seasons of the year.

  • PDF

A Study on the Evaporation Characteristics of Water or Nanofluid Droplets on a Heated Surface (물과 나노유체 액적의 고온 벽면에서의 증발 특성에 관한 연구)

  • Kim, J.H.;Lee, K.J.;Jung, S.W.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.177-183
    • /
    • 2016
  • In this study, the evaporation characteristics of water or nanofluid droplets on a heated surface was investigated by visualization of the evaporation process and evaluation of the heat transfer coefficient using the droplet temperature measured. The evaporation characteristics was compared between water and nanofluid droplets and the effects of the mass ratio of nanofluid and the inclination of heated surface were analyzed. The heat transfer rate of nanofluid droplet was higher than that of water droplet. The heat transfer coefficient was increased with the increase of the mass ratio of nanofluid. The effect of the inclination of heated surface was much higher than that of fluid type used, which indicates that the inclination of heated surface should be considered as one of influential parameters in the spray cooling process.