A Study on the Choice of Proper Region for Moving Cage Culture Facilities (이동식 가두리 양식장의 이동적지 선정에 관한 연구)

  • 조규대;박성은;고우진
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.83-94
    • /
    • 1999
  • A Study on the choice of proper region for moving cage culture facilities were carried out in the South Sea of Korea. Optimum temperatures of habitats for cage culture fishes, Sebastes schlegeli, Paralichthys olivaceus, Seriola quinqueradiata, Lateolabrax japonicus, Pagrus major, Takifugu vermicularis, and Mugil cephalus were 18~26$^{\circ}C$, 10~$25^{\circ}C$, 15~29$^{\circ}C$, 15~29$^{\circ}C$, 15~3$0^{\circ}C$, 15~$25^{\circ}C$, and 19~27$^{\circ}C$, respectively. In winter, wintering regions for continuous growth of fishes were proper around Komundo, Sorido, Soimal, Gadukdo and Chejudo for Paralichthys olivaceus and Lateolabrax japonicus, while Seoguipo and Udo for Seriola quinqueradiata, Pagrus major and Takifugu vermicularis. Sanji was not proper for wintering region because variation of water temperature is large by effect of strong northwestern wind. Wintering regions of Sebastes schlegeli and Mugil cephalus were not in the south of Korea. In summer, proper regions for fishes to avoid from damage by red tide were Komundo and around Chejudo. No red tide has occurred in these regions for 6 years. Mokpo and Yoja Bay were not proper for moving region because the former had strong tides and the latter had only one exit out of the bay which made it impossible to move cages in other route when dangerous red tides burst into.

  • PDF

A Study on the Improvement of the Disaster Prevention and Control System for Underpasses by Analytic Hierarchy Process (계층분석법을 통한 지하차도 재해 예방 및 제어 시스템 개선 연구)

  • Kim, Phil Do;Kim, Kyoung Soo;Moon, Yoo Mi
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.734-746
    • /
    • 2020
  • Purpose: Increase in the size and number of underpasses rises occurrence of disasters such as fire and flooding inundation in underpasses. In the occurrence of disasters, the underpasses are more vulnerable to expose of crucial disasters than the general roads due to they are built underground. Therefore, The purpose of this paper is to derive system improvement items to prevent and control disasters in underpasses. Method: A hierarchical model of disaster impact factors and alternatives was developed based on prior researches and expert advices on disaster analyses and impact factors in the underpasses. The developed model was employed for surveys of pairwise comparison, and rankings of improvement were determined by applying the AHP method. Result: With a consistency of the surveys, results of relative weights of evaluation criteria(traffic accidents, fire, flooding inundation) and alternatives(law, system/planning, maintenance/human factor/environment) shows that improvement of laws and system related to the fire disaster is a top priority to prevent and control disaster of the underpasses. Conclusion: From experts' point of view, strengthening laws and systems related to disater prevention facilities such as water spray facilities, external(ground) exit in relation to fire in underpasses showed that it is an alternative to prevent disasters and minimize damage to underpasses.

Monitoring Urban Ecological corridors in Gwanggyo New Town Using Camera Trapping (카메라트래핑을 활용한 광교신도시 내 도시형 생태통로 모니터링)

  • Park, Il-Su;Kim, Whee-Moon;Kim, Seoung-Yeal;Park, Chan;Song, Won-Kyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.1
    • /
    • pp.69-80
    • /
    • 2021
  • The new town in Korea, developed as a large-scale housing plan, has created urban ecological corridors to provide habitat and movement routes to wildlife and to promote natural ecological flow. This study aimed to investigate the use of wildlife in 10 ecological corridors in Gwanggyo New Town through camera trap technology and confirm effectiveness by identifying environmental factors affecting the use of wildlife's urban ecological corridors. Our researchers installed 20 unmanned sensor cameras at each the entrance and exit of the ecological corridors, and monitored urban wildlife for 10 weeks. According to the monioring results, the main species in Gwanggyo New Town were identified not only raccons, cats, water deer, korean hare and avain but also magpies, dove, eurasian tree sparrow, ring-necked pheasant, and eurasian jay. The number of uses ecological corridors of urban residents was 801(13.49%), as high as that of urban wildlife (1,140, 19.20%), which was judged to have disturbed the use of ecological corridors by wildlife. However, most dominant species of urban wildlife are nocturnal so that, it was judged that they share home range with urban residents at a time interval. In addition, according to the correlation analysis results between the mammal using rate of the urban ecological corridors and environmental factors(ecological corridor-specific length, ecological corridor-specific width, cover degree, shielding degree, connected green area, separation of movement routes, and presence of streetlights), environmental factors were not statistically significant. However, the more the area of green space connected to ecological corridors, the more increasing the mammal using rate of ecological corridor(r=0.71, p<0.05). Therefore, the area of green space connected to the ecological corridors that is associated with rate of wildlife using corridors should be considered as a priority when developing an urban ecological corridors. In the future, this study will extend the observation period of the ecological corridors and continuously accumulate data by adding the number of observation cameras. Furthermore, it is expected that the results of this study can be used as basic data for the standards for urban ecological corridors installation.

A study on the utilization of abrasive waterjet for mechanical excavation of hard rock in vertical shaft construction (고강도 암반에서 수직구 기계굴착을 위한 연마재 워터젯 활용에 관한 연구)

  • Seon-Ah Jo;Ju-Hwan Jung;Hee-Hwan Ryu;Jun-Sik Park;Tae-Min Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.5
    • /
    • pp.357-371
    • /
    • 2023
  • In cable tunnel construction using TBM, the vertical shaft is an essential structure for entrance and exit of TBM equipment and power lines. Since a shaft penetrates the ground vertically, it often encounters rock mass. Blasting or rock splitting methods, which are mainly used to the rock excavation, cause public complaints due to the noise, vibration and road occupation. Therefore, mechanical excavation using vertical shaft excavation machine are considered as an alternative to the conventional methods. However, at the current level of technology, the vertical excavation machine has limitation in its performance when applied for high strength rock with a compressive strength of more than 120 MPa. In this study, the potential utilization of waterjet technology as an excavation assistance method was investigated to improve mechanical excavation performance in the hard rock formations. Rock cutting experiments were conducted to verify the cutting performance of the abrasive waterjet. Based on the experimental result, it was found that ensuring excavation performance with respect to changing in ground conditions can be achieved by adjusting waterjet parameters such as standoff distance, traverse speed and water pressure. In addition, based on the relationship between excavation performance, uniaxial compressive strength and RQD, it was suggested that excavation performance could be improved by artificially creating joints using the abrasive waterjet. It is expected that these research results can be utilized as fundamental data for the introduction of vertical shaft excavation machines in the future.

The Experimental Study of Distribution Characteristics of Lift-force Acting under Pier Deck (잔교상판(棧橋床板)에 작용(作用)하는 양압력(揚壓力) 분포특성(分布特性)에 관한 실험적(實驗的) 연구(硏究))

  • Park, Sang Kil;Park, Hyun Soo;Ahn, Ik Seong;Kim, Woo Saeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1B
    • /
    • pp.83-90
    • /
    • 2009
  • This study describes the characteristics of distribution of lift-force acting under pier deck through physical experiment. The shape of peak wave pressure was sharp when compressed air existed but was not sharp without that. Values of lift-force was different between edge point and center point in the same block. Distribution of lift-force was expressed differently owing to dimensionless of deck length (l/L), wave steepness (H/L), clearance height per wave height (D/H). The dimensionless factor of D/H affected on the lift-force the clearance between still water surface and decks. This decided the maximum of lift-force. In the case of the same values of D/H, the lift-force are changed by the wave steepness (H/L). Because (D/H) become smaller as the wave steepness (H/L) is increased the height of decks must be decided with the condition which don't have the clearance with $D_{max}$ for the stable design of deck of pier. Effect of reducing lift force was greater in the on-shore than the off-shore according to compressed air existence. This researches points out that design of deck should retain compressed air in order to reduce wave lift force.

Fermentation of Waste Woody Biomass for the Production of Bioenergy (바이오에너지생산을 위한 목질계 폐바이오매스의 발효)

  • Cho, Nam-Seok;Choi, Tae-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.147-158
    • /
    • 2008
  • In this study, fermentation characteristics of waste agricultural and forest biomass for production of heat energy were focused to be used in agricultural farm households. The purpose of this study was focused on seeking practical utilization of agricultural and forest biomass wastes in agricultural farm households in the form of thermal energy by means of simple fermentation process. Fermentation process was performed in terms of different raw-materials and their mixture with different ratios. Urea, lime, and bioaids were added as fermenting aids. Moisture contents of fermenting substrates were adjusted to 55~65%. In order to optimize the fermentation process various factors, such as raw-materials, moisture contents, amount of fermenting aids, and practical measurement of hot-water temperature during fermentation were carefully investigated. The optimum condition of fermenting process were obtained from hardwood only and hardwood: softwood (50 : 50) beds. In case of hardwood only the highest temperature was recorded between 60 to $90^{\circ}C$ the lowest temperature was determined to more or less $40^{\circ}C$ and the average temperature was ranged to $50{\sim}60^{\circ}C$ and this temperature ranges were maintained up to 20~30 days. The optimum amount of additives were estimated to ca. 15 kg of urea, 20 kg of bioaids, and 10 kg of lime for 1 ton of substrate. To reach the highest temperature the optimum moisture content of fermenting substrate was proved to 55% among three moisture content treatments of 45%, 55% and 65%. The temperature of hot-water tank installed in fermenting bed of hardwood : grass (50 : 50) showed very different patterns according to measuring positions. In general, temperatures in the mid- and upper-parts of substrate piling were relative higher than lower and surface parts during 45-day fermentation process. The maximum temperature of fermenting stage was determined to $65^{\circ}C$, minimum temperature, more or less $40^{\circ}C$, and average temperature was $60^{\circ}C$. The water temperature of tank exit was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. It could be concluded that fermentation process of waste agricultural and forest biomass produces a considerable amounts of heat, averaging about $50{\sim}60^{\circ}C$ for maximum 3 months by using the heat exchanger (HX-helical type).

Transport of Zn Ion under various pH Conditions in a Sandy Soil (사질토양에서의 pH조건에 따른 Zn의 이동특성)

  • Park, Min-Soo;Kim, Dong-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2000
  • Adsorption onto the surfaces of solid particles is a well known phenomenon that causes the retardation effect of heavy metals in soils. For adequate remediation of soil and groundwater contamination, it is important to investigate the mobility of heavy metals that largely depends on pH conditions in the soil water since adsorption of heavy metals is pH-dependent. In this study, we investigated the transport of Zn ion under various pH conditions in a sandy soil by conducting batch and column tests. The batch test was performed using the standard procedure of equilibrating fine fractions collected from the soil with eleven different initial $ZnCl_2$ concentrations, and analysis of Zn ion in the equilibrated solutions using ICP-AES. The column test consisted of monitoring the concentrations of soil solutions exiting the soil column with time known as a breakthrough curve (BTC). We injected respectively $ZnCl_2$ and KCl solutions with the concentration of 10 g/L as a tracer in a square pulse type under three different pH conditions (7.7, 5.8, 4.1) and monitored the flux concentration at the exit boundary using an EC meter and ICP-AES. The resident concentration was also monitored at the 10cm-depth by Time Domain Reflectometry (TDR). The results of batch test showed that ion exchange process between Zn and other cations (Ca, Mg) was predominant. The retardation coefficients obtained from adsorption isotherms (Linear, Freundlich, Langmuir) resulted in the various values ranging from 1.2 to 614.1. No retardation effect but ion exchange was found for the BTCs under all pH conditions. This can be explained by the absence of other cations to desorb Zn ion from soil exchange sites under the conditions of ETC experiment imposing blank water as leachate in steady-state flow. As pH decreased, the peak concentration of Zn increased due to the competition of Zn with hydrogen ions ($H^+$) and the concentrations of other cations decreased. The peak concentration of Zn was increased by 12.7 times as pH decreased from 7.7 to 4.1.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer (해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정)

  • Lee, Jae-Seong;Kim, Kee-Hyun;Yu, Jun;Lee, Pil-Yong;Jung, Rae-Hong;Lee, Wong-Chan;Han, Jung-Jee;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.64-72
    • /
    • 2004
  • We measured the vertical profiles of $O_2$, H$_2$S, and pH in sediment pore water beneath marine cage fish farms using a microsensor with a 25 ${\mu}{\textrm}{m}$ sensor tip size. The sediments are characterized by high organic material load. The oxygen consumption, hydrogen sulfide oxidation, and sulfate reduction rates in the microzonations (derived from the vertical distribution of chemical species concentration) were estimated by adapting a simple one-dimensional diffusion-reaction model. The oxygen penetration depth was 0.75 mm. The oxic microzonations were divided into upper and lower layers. Due to hydrogen sulfide oxidation within the oxic zone, the oxygen consumption rate was higher in the lower layer. The total oxygen consumption rate integrated with reaction zone depth was estimated to be 0.092 $\mu$mol $O_2$cm$^{-2}$ hr$^{-1}$ . The total hydrogen sulfide oxidation rate occurring within 0.7 mm thickness was estimated to be 0.030 $\mu$mo1 H$_2$S cm$^{-2}$ hr$^{-1}$ , and its turnover time in the oxic sediment layer was estimated to be about 2 minutes. This suggests that hydrogen sulfide was oxidized by both chemical and microbial processes in this zone. The molar consumption ratio, calculated to be 0.84, indicates that either other electron accepters exit on hydrogen sulfide oxidation, or elemental sulfur precipitation occurs near the $O_2$- H$_2$S interface. Total sulfate reduction flux was estimated to be 0.029 $\mu$mol cm$^{-2}$ hr$^{-1}$ , which accounted for more than 60% of total $O_2$ consumption flux. This result implied that the degradation of organic matter in the anoxic layer was larger than in the oxic layer.

Characteristics of Fish Utilization of the Nature-like Fishway Installed at the Beakjae Weir (백제보에 설치된 자연형 어도의 어류 이용 특성 분석)

  • Kim, Jeong-Hui;Yoon, Ju-Duk;Park, Sang-Hyeon;Lee, Jin-Woong;Baek, Seung-Ho;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.48 no.4
    • /
    • pp.212-218
    • /
    • 2015
  • In South Korea, various nature-like fishways recently been installed for use by a wide variety of fish species. However, limited attempts have been made to monitor the fish utilization. The present study was conducted to ascertain the frequencies and patterns of utilization of the fishway installed at Beakjae Weir. We collected fish species that use the fishway by installing a fyke net at the exit of the fishway at least once a month from April 2013 to October 2013. Additionally, in order to identify all fish species that can potentially use the fishway, we investigated the fish fauna downstream to Beakjae Weir (mainstream of the Geum River). We found that 10 species belonging to 2 families used the fishway; this accounted for 64% of the total species inhabiting the mainstream. The species that used the fishway most frequently were Microphysogobio jeoni, followed by Squaliobarbus curriculus and Opsariichthys uncirostris amurensis. The highest number of fish using the fishway was observed in August, which was positively correlated with the water temperature (Spearman rank correlation, $r_s$=0.743, P=0.035). The sizes of the fish using the fishway varied widely, with the total body length ranging from 39 mm to 550 mm. Analysis of the time-dependent utilization frequency revealed that most fish used the fishway during the night (20:00~08:00). Compared to other fishways installed along the Geum River, the fishway installed at Beakjae Weir was used by fewer species and fish. This may be attributed to the structural inadequacy of the fishway, thereby resulting in a low attraction efficiency. Therefore, measures should be adopted to enhance the fishway attraction and passage efficiency. The results of this study can be used to ensure efficient operation and management of the Beakjae Weir fishway as well as serve as basic data for developing and building nature-like fishways tailored to Korean situations.