• Title/Summary/Keyword: Water droplet impingement

Search Result 18, Processing Time 0.018 seconds

Numerical Study for the Influence of Environment Temperature on Offshore Arctic Pipeline and Impingement Erosion Analysis by using Thermal Flow Simulation (극지 해양 파이프라인 내부 유체의 온도별 영향 및 내부 충돌침식 분석)

  • Jo, Chul Hee;Lee, Jun-Ho;Jang, Choon-Man;Heang, Su-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.201-205
    • /
    • 2015
  • This paper describes thermal flow characteristic in various pipelines: straight pipeline and curved pipeline. In the Arctic and ocean area, pipelines are exposed to a extremely low temperature ($0{\sim}-40^{\circ}C$). In this situation, three-dimensional flow analysis should be analyzed to investigate thermal effects such as pressure drop, temperature change, velocity deficit and distribution change of liquid droplet of internal fluid. Also, due to freezing of water droplet, impingement erosion is expected in the curved pipeline. The stability of the pipelines can be influenced by impingement erosion. In this paper, multi-phase and multi-species analysis was introduced to analyze the flow characteristics and impingement erosion of Arctic and ocean pipelines.

An Experimental study on the drop size and velocity characteristic of drop by impinging jets (충돌분류에 의한 액적의 크기 및 속도특성에 관한 실험적 연구)

  • Han, Jae-Seob;Kim, Seon-Jin
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.30-37
    • /
    • 1999
  • The breakup characteristics of liquid sheet formed by the liquid rocket injector has a close relation with the combustion efficiency. In this paper, basic characteristics of droplet size and velocity distribution were measured with PDPA for the Like Doublet Impinging Injector. Test variables were the angle of impact, the diameter of orifice and jet velocity. Water was used as test fluid. As a result, for impingement angle less than 90 degree, following correlations were obtained between drop size and design parameters : $D_{32}({\mu}m)=295.0{\times}V^{-0.09}\times(2\theta)^{-0.1}{\times}d^{0.072}$. For impingement angle greater than 100 degree, drop sizes were increased but eventually converged to a certain limiting value.

  • PDF

Visualization Study on Microscale Wetting Dynamics of Water Droplets on Dry and Wet Hydrophilic Membranes

  • Park, Kyungjin;Kim, Seong Yeon;Hong, Jiwoo;Kim, Jong Hyun;Lim, Geunbae
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.277-281
    • /
    • 2022
  • The wetting dynamics of water droplets dispensed on the surface of dry and wet hydrophilic membranes were investigated experimentally from a microscale point of view. By using a high-speed, white-beam x-ray microimaging (WXMI) synchrotron, consecutive images displaying the dynamic motions of the droplets were acquired. Through analyzing the characteristics observed, it was found that the dry hydrophilic membrane showed local hydrophobicity at a certain point during the absorption process with apparent contact angles greater than 90. While on the other hand, the apparent contact angles of a water droplet absorbing into the wet membrane remained less than 90 and showed total hydrophilicity. The observations and interpretation of characteristics that affect the contact, wetting, recoiling, and dynamic behaviors of droplets are significant for controlling liquid droplet impingement in a desired manner.

Reliability Analysis Method for Repeated UT Measurement Data in Nuclear Power Plants (원전 배관의 반복 측정 데이터에 대한 신뢰도 분석 방법)

  • Yun, Hun;Hwang, Kyeong-Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.142-148
    • /
    • 2013
  • Safety is a major concern in Nuclear Power Plants (NPPs). Piping systems in NPPs are very complex and composed of many components such as tees, elbows, expanders and straight pipes. The high pressure and high temperature water flows inside piping components. As high speed water flows inside piping, the pipe wall thinning occurs in various reasons such as FAC (Flow Accelerated Corrosion), LDIE (Liquid Droplet Impingement Erosion) and Flashing. To inspect the wall thinning phenomenon and protect the piping from damages, piping components are checked by UT measurement in every overhaul. During every overhaul, approximately 200~300 components (40,000~60,000 UT data) are examined in NPPs. There are some methods from EPRI for evaluating wear rate of components. However, only few studies have been conducted to find out the raw data reliability for the wear rate evaluation. Securing the reliable raw data is the key factor for a reasonable evaluation. This paper suggests the reliability analysis method for the repeatedly measured data for wear rate evaluation.

Spray characteristics of misaligned impinging injectors

  • Subedi, Bimal;Son, Min;Kim, Woojin;Choi, Jangsu;Koo, Jaye
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1257-1262
    • /
    • 2014
  • The variances of atomization characteristics with the misalignment of injectors defined as the fraction of skewness for various angles of impingement and pressure conditions were studied using the doublet impinging injectors with a like-on-like arrangement. Water was used as simulant and the spray characteristics along with the changes in the skewness were analyzed using the methods of spray image photography. Experiment was carried for the impinging nozzles of orifice diameter of 1.2 mm within Reynolds numbers ranging from $9{\times}10^3-4.5{\times}10^4$ and the fraction of skewness considered for the experiment ranges from 0.0 to 0.9 at ambient temperature condition. Flat sheet with a distinct rim produced perpendicular to the plane of impinging jets goes ondisappear and sheet appears comparatively shorterwith the increase in fraction of skewness resulting the atomization of fluid droplet very close to impingement point with decrease in breakup length and increase in spray angle up to certain extent. The maximum allowable skewness was found as the result. The skewness up to the certain extent can be considered as the parameter to control the atomization characteristics of simulant inside the combustion chamberproviding the high economic performance of fuel and time.

Dynamic Boric Acid Corrosion of Low Alloy Steel for Reactor Pressure Vessel of PWR using Mockup Test (가압형 경수로 압력용기 재료인 저합금강의 동적 붕산 부식 실증 연구)

  • Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • This work is concerned with an evaluation of dynamic boric acid corrosion (BAC) of low alloy steel for reactor pressure vessel of a pressurized water reactor (PWR). Mockup test method was newly established to investigate dynamic BAC of the low alloy steel under various conditions simulating a primary water leakage incident. The average corrosion rate was measured from the weight loss of the low alloy steel specimen, and the maximum corrosion rate was obtained by the surface profilometry after the mockup test. The corrosion rates increased with the rise of the leakage rate of the primary water containing boric acid, and the presence of oxygen dissolved in the primary water also accelerated the corrosion. From the specimen surface analysis, it was found that typical flow-accelerated corrosion and jet-impingement occurred under two-phase fluid of water droplet and steam environment. The maximum corrosion rate was determined as 5.97 mm/year at the leakage rate of 20 cc/min of the primary water with a saturated content of oxygen within the range of experimental condition of this work.

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

A Study on Truncated Flapped Airfoil for Efficient Icing Wind Tunnel Test (효율적 결빙 시험을 위한 절단 익형 형상 연구)

  • Jung, Sung-Ki;Lee, Chang-Hoon;Nagdewe, Suryakant;Myong, Rho-Shin;Cho, Tae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.481-486
    • /
    • 2011
  • The evaluation of supercooled water droplet impingement characteristics of full-scale aircraft components in wind tunnels under icing conditions has been severely limited by the relative size of the component and the test facility. The concept of truncated airfoil sections has been suggested in order to extend the operational range of icing tunnels. With proper deflection of the small trailing-edge flap on the truncated airfoil the local pressure distribution may remain very close to that of the full-scale airfoil. In this study the shape of a truncated flapped airfoil is investigated for various deflection angles. To validate the truncated flapped airfoils, air flow and collection efficiency over the truncated airfoil are compared with the results of the full-scale airfoil obtained from the state-of-the-art icing simulation code.