A Study on Dielectrical Constant under Ground Conditions (지반조건에 따른 유전상수 변화에 관한 연구)

  • Cho, Jinwoo;Cho, Wonbeom;Kim, Jinman;Choi, Bonghyuck
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.12
    • /
    • pp.17-25
    • /
    • 2012
  • In this study, dielectrical constant of the ground was measured using TDR method and correlated with water contents and density of ground. In order to evaluate the applicability as a cavity exploration, model experiments were carried out to analyze the effects of cavity size on the dielectrical constant. Test result indicated that dielectrical constant of the ground tended to linearly increase with the increase in water contents and density, which can be represented in a certain relational expression. Also, the dielectrical constant of ground varied sensitively with the cavity size of ground. The results conclude that the dielectrical constant, water contents and density of the ground proved to have a correlation among them, and the dielectrical constant is expected to be a basic data on cavity exploration.

Optimal Rain Gauge Density and Sub-basin Size for SWAT Model Application (SWAT 모형의 적용을 위한 적정 강우계밀도의 추정)

  • Yoo, Chul-Sang;Kim, Kyoung-Jun;Kim, Nam-Won
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.5 s.154
    • /
    • pp.415-425
    • /
    • 2005
  • This study estimated the optimal rain gauge density and sub-basin size for the application of a daily rainfall-runoff analysis model called SWAT (Soil and Water Assessment Tool). Simulated rainfall data using a WGR multi-dimensional precipitation model (Waymire et al., 1984) were applied to SWAT for runoff estimation, and then the runoff error was analyzed with respect to various rain gauge density and sub-basin size. As results of the study, we could find that the optimal sub-basin size and the representative area of one rain gauge are similar to be about $80km^2$ for the Yong-Dam dam basin.

Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties (종이 물성에 따른 판형 전열교환기의 성능)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

Effect of Paper Properties on the Performance of a Enthalpy Exchanger (종이 물성이 전열교환 엘리먼트 성능에 미치는 영향)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

Effect of Organic Additives on Microstructure and Green Density of Zirconia Granules Using Water Solvent (유기첨가제가 수계에서 제조된 지르코니아 과립의 미세구조 및 성형밀도에 미치는 영향)

  • Jung, Ji-Hwan;Lee, Sang-Jin
    • Journal of Powder Materials
    • /
    • v.24 no.2
    • /
    • pp.147-152
    • /
    • 2017
  • Spherical-type zirconia granules are successfully fabricated by a spray-drying process using a water solvent slurry, and the change in the green density of the granule powder compacts is examined according to the organic polymers used. Two organic binders, polyvinyl alcohol (PVA) and 2-hydroxyethyl methacrylate (HEMA), which are dissolved in a water solvent and have different degrees of polymerization, are applied to the slurry with a plasticizer (polyethylene glycol). The granules employing a binder with a higher degree of polymerization (PVA) are not broken under a uniaxial press; consequently, they exhibit a poor green density of $2.4g/cm^3$. In contrast, the granule powder compacts employing a binder with a lower degree of polymerization (HEMA) show a higher density of $2.6g/cm^3$ with an increase in plasticizer content. The packing behavior of the granule powders for each organic polymer system is studied by examining the microstructure of the fracture surface at different applied pressures.

Measurement of Hydroxyl Radical Density at Bio-Solutions Generated from the Atmospheric Pressure Non-Thermal Plasma Jet

  • Kim, Yong Hee;Hong, Young June;Uhm, Han Sub;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.494-494
    • /
    • 2013
  • Atmospheric pressure non-thermal plasma of the needle-typed interaction with aqueous solutions has received increasing attention for their biomedical applications [1]. In this context, surface discharges at bio-solutions were investigated experimentally. We have generated the non-thermal plasma jet bombarding the bio-solution surface by using an Ar gas flow and investigated the emission lines by OES (optical emission spectroscopy) [2]. Moreover, The non-thermal plasma interaction with bio-solutions has received increasing attention for their biomedical applications. So we researched, the OH radical density of various biological solutions in the surface by non-thermal plasma were investigated by Ar gases. The OH radical density of DI water; deionized water, DMEM Dulbecco's modified eagle medium, and PBS; 1x phosphate buffered saline by non-thermal plasma jet. It is noted that the OH radical density of DI water and DMEM are measured to be about $4.33{\times}1016cm-3$ and $2.18{\times}1016cm-3$, respectively, under Ar gas flow 250 sccm (standard cubic centimeter per minute) in this experiment. The OH radical density of buffer solution such as PBS has also been investigated and measured to be value of about $2.18{\times}1016cm-3$ by the ultraviolet optical absorption spectroscopy.