• 제목/요약/키워드: Water cycle characteristics

검색결과 406건 처리시간 0.046초

LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성 (Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy)

  • 김경훈;오재형;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.

담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석 (Analysis of combined cycle for desalination process and $CO_2$ refrigeration system)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

물의 순환 학습 상황에서 초등학생의 시스템 사고의 특징 (Characteristics of Elementary Students' System Thinking in Learning of Water Cycle)

  • 김보민;맹승호
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제39권3호
    • /
    • pp.412-432
    • /
    • 2020
  • The purpose of this study is to explore the characteristics and the level of fourth grade elementary students' system thinking when they learn the unit of "Journey of Water" in terms of four key elements of system thinking such as understanding of the structure of a system, non-linearity and cyclic features, inter-relations and feedback between system properties, and temporal and invisible aspects of a system. Data included students' worksheets and their responses to a set of Likert-scaled and written assessment items on water cycle. The results showed that the level of students' system thinking did not have any hierarchy in relation to the key elements of water cycle system. In addition, the aspects of individual student's system thinking on its sub-elements were different from each other. Also, there were core ideas of system thinking which were intensively considered according to a given context to understand a complex systemic subject. When students learn water cycle, understanding of non-linearity and inter-relations were weaker compared with other key elements of system thinking. Therefore, if these two factors are taught in advance, it can promote understanding of whole system of water cycle.

SBF Conceptual Representation을 활용한 초등학교 6학년 학생들의 자연현상 개념 분석 (An Analysis of the Conceptions about the Nature Phenomenon Using SBF Conceptual Representation in the 6th Students)

  • 문병찬;김해경
    • 대한지구과학교육학회지
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of this study was to analysis the 6th students' conceptions of the nature phenomenon focused on the systematic characteristics. For this study, 12 students of the 6th grades participated in special class for testing their conceptions about the water cycle in the earth system. And we analyzed the outcomes of students' conceptions based on SBF conceptual representation. The results indicate that most of the subjects perceived that the water cycle in earth system wasn't complex system maintaining its existence and functions as a whole through the interaction of its parts but simple system maintaining some actions between atmosphere and hydrosphere, geosphere, biosphere(biological world). And they didn't perceive the characteristics of the water cycle whose all parts must be presented the change of volume between vapor and water, glacier proposing the total hydro-volume are established in the earth system. Based on the results, it was suggested that the main goals of the schools' science education should be to provide students who understand the water cycle system as attaching importance to form with the skills needed to coherent understanding of the essential qualities for the nature phenomenon system.

  • PDF

고성능 흡수냉동 사이클의 특성 시뮬레이션 (Simulation of the Characteristics of High-Performance Absorption Cycles)

  • 윤정인;오후규;이용화
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Budyko 프레임워크 기반 동적 물수지 모형을 활용한 월 단위 물순환 평가체계 개발 (Development of Monthly Hydrological Cycle Assessment System Using Dynamic Water Balance Model Based on Budyko Framework)

  • 김계웅;황순호;전상민;이현지;김시내;강문성
    • 한국농공학회논문집
    • /
    • 제64권2호
    • /
    • pp.71-83
    • /
    • 2022
  • In this study, an indicator and assessment system for evaluating the monthly hydrological cycle was prepared using simple factors such as the landuse status of the watershed and topographic characteristics to the dynamic water balance model (DWBM) based on the Budyko framework. The parameters a1 of DWBM are introduced as hydrologic cycle indicators. An indicator estimation regression model was developed using watershed characteristics data for the introduced indicator, and an assessment system was prepared through K-means cluster analysis. The hydrological cycle assessment system developed in this study can assess the hydrological cycle with simple data such as land use, CN, and watershed slope, so it can quickly assess changes in hydrological cycle factors in the past and present. Because of this advantage is expected that the developed assessment system can predict changes in the hydrological cycle and use an auxiliary tool for policymaking.

CAT을 이용한 저수지 수위 예측 (Prediction of Reservoir Water Level using CAT)

  • 장철희;김현준;김진택
    • 한국농공학회논문집
    • /
    • 제54권1호
    • /
    • pp.27-38
    • /
    • 2012
  • This study is to analyse the hydrological behavior of agricultural reservoir using CAT (Catchment hydrologic cycle Assessment Tool). The CAT is a water cycle analysis model in order to quantitatively assess the characteristics of the short/long-term changes in watershed. It supports the effective design of water cycle improvement facilities by supplementing the strengths and weaknesses of existing conceptual parameter-based lumped hydrologic models and physical parameter-based distributed hydrologic models. The CAT especially supports the analysis of runoff processes in paddy fields and reservoirs. To evaluate the impact of agricultural reservoir operation and irrigation water supply on long-term rainfall-runoff process, the CAT was applied to Idong experimental catchment, operated for research on the rural catchment characteristics and accumulated long term data by hydrological observation equipments since 2000. From the results of the main control points, Idong, Yongdeok and Misan reservoirs, the daily water levels of those points are consistent well with observed water levels, and the Nash-Sutcliffe model efficiencies were 0.32~0.89 (2001~2007) and correlation coefficients were 0.73~0.98.

갇힌 공기를 고려한 불포화토 침투 해석에 관한 연구 (Analysis of Rainfall Induced Infiltration Considering Occluded Air in Unsaturated Soils)

  • 이준용;유찬;김욱기;김동욱
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.129-139
    • /
    • 2012
  • Accurate modeling rainfall induced landslide and slope stability requires a detailed knowledge of the distribution of material strength characteristics and suction distribution. However, material properties obtained from the drying cycle are still used for infiltration analysis in many cases, even though material properties of wetting cycle are quite different from those of drying cycle due to hydraulic hysteresis and air occlusion. Therefore, the selection of proper material properties such as soil-water retention curve (SWRC) and the hydraulic conductivity function (HCF) reflecting characteristics of wetting cycle and air occlusion is an essential prerequisite in order to simulate the infiltration phenomena and to predict the suction and water content distribution in unsaturated soils. It is concluded that the simulation of infiltration with material properties from the drying cycle did not reasonably match with experimental outputs. Further discussion is made on how to describe the material properties considering air occlusion during wetting cycle over the entire suction range in order to simulate infiltration phenomena.

WEP 모형을 이용한 도림천 유역 물순환 모의 (Water Cycle Simulation for the Dorimcheon Catchment Using WEP Model)

  • 이승종;김영오;이상호;이길성
    • 한국수자원학회논문집
    • /
    • 제38권6호
    • /
    • pp.449-460
    • /
    • 2005
  • 본 연구에서는 전형적인 도시하천으로 왜곡된 물순환을 보이는 도림천 유역에 대해서 WEP(Water and Energy transfer Processes) 모형을 이용하여 물순환 모의를 수행하였다. 과거(l975년)와 현재(2000년)의 토지이용도를 이용한 모의를 통해 도시화에 의한 불투수율 증가가 유출특성에 미치는 영향을 분석하였으며, 모의결과 도시의 개발로 인해 과거보다 첨두 도달시간은 감소하고, 첨두 및 총유출량이 증가한 것으로 나타났으며, 침투량과 기저유출량이 감소한 것을 확인할 수 있었다. 또한 왜곡된 물순환을 회복하기 위한 대안으로 침투트랜치와 투수성 포장재의 설치 효과에 대한 모의를 수행하였으며, 모의결과 두 가지 대안을 함께 적용했을 경우에 도시개발 이전의 유출특성에 근접하는 것을 확인할 수 있었다.

감액 특성 향상을 위한 하이브리드(Sb/Ca) 액식 연축전지 개발 (Development of Hybrid (Sb/Ca) Flooded Lead-Acid Battery for Minimizing Water Loss)

  • 송승윤;임태섭;김성준;정연길;양승철
    • 한국재료학회지
    • /
    • 제32권3호
    • /
    • pp.146-152
    • /
    • 2022
  • One disadvantage of deep cycle flooded lead-acid batteries is increasing water loss caused by use of (+) Pb-Sb / (-) Pb-Sb alloy grid. Water loss is generated by the emission of hydrogen gas from the (-) electrode during battery charging. In this paper, we maintain cycle life aspect through the development of hybrid flooded lead-acid batteries to which a (+) Pb-Sb / (-) Pb-Ca grid is applied and deal with the improvement of water loss. The amount of water loss compared to that of the (-) Pb-Sb grid decreased when Ca was added to the (-) Pb grid. For the (-) Pb-Ca grid, it was confirmed that the time to reach 0.0 V, at which water decomposition occurs, was increased compared to that of the (-) Pb-Sb grid at the NPV (Negative Potential Voltage). In the cycle life test conducted with the BCI (Battery Council International) standard, compared to the (+) Pb-Ca grid, the (+) Pb-Sb grid increased the life cycle of the batteries and the (+) Pb-Ca grid showed an early end of life due to PbO corrosion layer generation, as determined through SEM / EDS and Tear Down analysis. In conclusion, by addition of Sb to (+) Pb grid and Ca to (-) Pb grid, we developed a hybrid flooded lead-acid battery that meets user requirements to improve water loss characteristics and preserve cycle life characteristics.