수막하우스의 유량 및 수온에 따른 열전달 특성 분석 (Analysis of Heat Transfer Characteristics in Response to Water Flow Rate and Temperature in Greenhouses with Water Curtain System)

  • 김형권;김승희;권진경
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.270-276
    • /
    • 2016
  • This study analysed overall heat transfer coefficient, heat transmission, and rate of indoor air heating provided by water curtain in order to determine the heat transfer characteristic of double-layered greenhouse equipped with a water curtain system. The air temperatures between the inner and outer layers were determined by the water flow rate and inlet water temperature. Higher water flow rate and inlet water temperature resulted in the increased overall heat transfer coefficient between indoor greenhouse air and water curtain. However, it was found that with higher levels of water flow rate and inlet water temperature, indoor overall heat transfer coefficient was converged about $10W{\cdot}m^{-2}{\cdot}^oC^{-1}$. The low correlation of overall heat transfer coefficient between water curtain and air within double layers was likely because the combination of greenhouse shape, wind speed and outdoor air temperature as well as water curtain affected the heat transfer characteristics. As water flow rate and inlet water temperature increased, the heat transferred into the greenhouse by water curtain also tend to rise. However it was demonstrated that the rate of heat transmission from water curtain into greenhouse with water curtain system using underground water was accounted for 22% to 28% for total heat lost by water curtain. The results of this study which quantify heat transfer coefficient and net heat transfer from water curtain may be a good reference for economical design of water curtain system.

가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구 (A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System)

  • 유우준;남준석;김동준;이정균;유홍선
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.53-58
    • /
    • 2012
  • 본 연구에서는 가연성 물질을 고려한 워터커튼 시스템(Water Curtain System)의 열 및 연기유동 제어 특성을 실험적으로 분석하였다. 이를 위해서 Room Corner Tester(RCT)를 사용하여 연료의 종류가 소나무(PineWood)와 가솔린(Gasoline)인 경우 각각의 발열량(Heat Release Rate)을 구하였으며, 워터커튼용 화재실험 장치를 제작하여 화원근방에서 5m 떨어진 지점의 천장 부근에 분사각도 $180^{\circ}$, 오리피스 직경 8.2 mm의 노즐(Nozzle)을 설치한 후 목재와 가솔린 각각에 대해서 화재실험을 실시하여 워터커튼 전후의 온도분포와 가시도를 측정하였다. 그결과 워터커튼 시스템의열및연기유동 제어는 가연성 물질의 연소특성에 따른 고온의 연기발생량과 분사 노즐에 의한 유동현상이 중요한 상관관계를 갖고 있음을 확인하였다.

순환식 수막하우스의 수온에 따른 플라스틱 온실 내 온도변화 분석 (Analysis of Temperature Changes in Greenhouses with Recirculated Water Curtain System)

  • 김형권;전종길;백이;표희영;정재완;김용철
    • 생물환경조절학회지
    • /
    • 제24권2호
    • /
    • pp.93-99
    • /
    • 2015
  • 순환식 수막시스템의 적정 수온을 결정하는데 필요한 기초자료를 제공하기 위하여 딸기를 토경재배하고 있는 실험온실에서 외부온도, 수막용수의 수온 및 야간시간대에 따른 처리방식별 온실 내부 환경변화를 비교 분석하였다. 대조구는 무수막 온실이고, 처리구는 수온이 $10^{\circ}C$, $15^{\circ}C$로 각각 설정된 순환식 수막온실로서 모두 무가온 및 추가적인 보온자재의 투입이 없는 상태를 말한다. 수막이 직접 살수되는 2중 비닐하우스는 폭 5.5m, 길이 55m이고, 분당 살수되는 평균 수막유량은 38.5~44.5L로 나타났다. 3가지 처리조건 모두에서 외부온도와 내부온도는 양의 선형관련성이 매우 높게 나타났으며 처리구(10, $15^{\circ}C$)의 외부온도에 대한 상관성은 유사한 수준으로 분석되었다. 보온효과는 수온 $15^{\circ}C$ 처리구가 수온 $10^{\circ}C$ 처리구보다 $1.3^{\circ}C$ 정도 우수한 것으로 나타났다. 외부온도가 약 $-8.1{\sim}8.6^{\circ}C$ 범위에서 변화할 때, 처리조건 별 최저온도는 무처리구, 수온 $10^{\circ}C$ 처리구, 수온 $15^{\circ}C$ 처리구가 외부에 비해 각각 6.4, 11.0, $12.3^{\circ}C$ 정도 높게 유지되는 것으로 나타났다. 평균 온도는 무처리구, 수온 $10^{\circ}C$ 처리구, 수온 $15^{\circ}C$ 처리구의 순으로 높아지고 온도변화폭은 오히려 작아지는 경향을 보였다. 외부 최저온도가 $-1.3^{\circ}C$, 평균온도가 $1.5^{\circ}C$인 날은 수막시스템의 수온을 $10^{\circ}C$로, 외부 최저온도가 $-4.7^{\circ}C$, 평균온도가 $-0.2^{\circ}C$ 인 날은 수온을 $15^{\circ}C$로 설정해도 온실의 목표온도($5^{\circ}C$) 유지가 가능한 것으로 나타났다. 처리조건별 야간시간대(일몰 후, 자정, 일출 전, 일출 후)에 따른 온실 내부와 외부의 온도는 전반적으로 일몰직후가 가장 높고, 이후 서서히 감소하여 일출직전이 가장 낮아지는 경향을 보였다. 따라서 온실의 목표온도 유지를 위해서는 일출직전 시간대에 특히 집중적인 관리가 필요하며, 순환식 수막시스템의 수온을 획일적으로 $15^{\circ}C$ 이상으로 결정하기 보다는 외부온도 변화, 야간시간대, 재배작물에 따라 다르게 결정하는 것이 타당한 것으로 판단된다.

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구 (Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire)

  • 박형주;최영상;지남용
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

지하 유류비축기지 수벽공의 효율에 관한 현장계측 및 수치 해석 연구 (Field Measurements and Numerical Analysis on the Efficiency of Water Curtain Boreholes in Underground Oil Storages)

  • 이경주;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 1998
  • This study was performed to suggest to suggest suitable design conditions of water curtain system through analysis on pressure down in boreholes by hydraulic tests carried out I construction fields for underground oil storages. The influence by hydraulic conductivities of rock mass around boreholes on pressure down in boreholes was analysed. The relationship between array of boreholes and their pressure down was also analysed. Groundwater flow analysis on crude oil and LPG storages was carried out to evaluate results of field tests and to investigate distribution of hydraulic gradient in rock mass around cavern using finite difference method. As the results, hydraulic tests showed that pressure down in boreholes was inverse proportional to the hydraulic conductivity of surrounding rock mass. The rate of pressure down of boreholes was not influenced by water curtain system more than 20m over cavern and was proportional to installation interval of boreholes. The hydraulic gradient in rock mass around cavern was proportional to distance and interval of boreholes and its value was not satisfactory to oil tightness condition in case of no water curtain system.

  • PDF

수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구 (Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling)

  • 김경수;정지곤
    • 지질공학
    • /
    • 제12권1호
    • /
    • pp.35-51
    • /
    • 2002
  • 본 논문은 화산암지역에 건설되는 비축기지를 대상으로 지표지질조사, 지표단열조사, 시추조사, 수리시험 결과 등을 토대로 지하수유동 수치모델 해석을 통하여 저유공동의 기밀성 요건을 만족시킬 수 있는 수벽시스템을 설정하고, 이러한 시스템 하에서의 공동유입량과 인접시설과의 수리간섭 영향을 평가하였다. 수리지질 안정성 해석을 위한 접근방법 3차원 연속체 수치모델링과 더불어 이의결과를 비교 또는 보완하기 위한 단열망 모델링 해석방법을 병행하였다. 저유공동의 심도를 결정하고 투수성단열의 확률적인 상호연결성 정도를 계산한 결과와 연직 수리경사, 수벽공 효율성, 저유공동과 수벽시스템간 이격거리 등의 제반 요건을 만족시키는 수벽시스템을 계산하였다. 연속체 모델에 의한 저유공동으로의 누수량은 건설기간 중에는 130 ~ 140m$^3$/day, 운영 중에는 약 120m$^3$/day일 것으로 예측되었고, 단열망 모델에서는 80~175m$^3$/day의 범위인 것으로 계산되었다. 신규 시설의 건설로 인하여 기존 시설지구의 함양유역 감소가 불가피하고, 이로 인하여 지하수위 강하 및 유동량의 감소가 발생될 것으로 예상되므로, 보수적인 관점에서 기준 지하수위를 유지하기 위하여 인공적인 수압을 가해줄 수 있는 별도의 지상 혹은 지하의 수직 수벽시스템이 요구된다.

수막재배 단동비닐하우스의 태양열 축열이용 효과분석 (Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System)

  • 이성현;유영선;문종필;윤남규;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

지하공동굴착 시 수리지질조사 자료를 이용한 저장공동 심도의 지하수체계 특성 연구 (Characterization of a groundwater system by subsurface hydrogeological investigation data)

  • 조성일;김천수;김경수;송무영;전한석
    • 지질공학
    • /
    • 제14권1호
    • /
    • pp.93-104
    • /
    • 2004
  • 본 논문은 지하시험시설을 이용한 수리지질환경 연구의 대안으로 지하 유류 저장시설 건설과정 중 도출된 자료를 이용하여 저장공동 심도에서의 지하수체계를 해석해 보고자 하였다. 지하공동굴착과 동시에 지표 관측공 28개를 통해 지하수위가 계측되었고, 수평 수벽공 95개와 수직 수벽공 63개에 의해 압력 및 주입량이 일일주기로 측정되었다. 또한 수리적 연결성 확인을 위한 수벽 공간 수리간섭시험이 수행되었다. 저.고 경사의 투수성 단열의 수리적 연결성에 따라 주입압의 분포양상이 다르게 나타났다. 수평 수벽공의 압력분포에 의해 수리특성을 달리하는 세 개의 수리영역으로 구분 가능하였고, 공동 C-2 < C-1 < C-3 영역 순으로 지하수압이 높은 것으로 해석되었다. 지하수압이 높은 C-3 영역은 1차 적인 지구화학 자료에 의해 심부 지하수를 많이 포함하는 특성을 보이고 있고, 일부 수벽공은 천부지하수의 특성을 나타내며 다른 구역보다 높은 지하수압을 유지하고 있다. C-2 상부의 수벽공은 지하수압이 낮고 주입량도 많지 않아 상부 지하수체와의 수리적 연결성이 불량한 지하수 영역으로 해석할 수 있다. 본 연구결과는 단열암반의 불균질성 및 규모종속성에 따른 규모별 지하수부존체계를 이해하고 지하수체계에 대한 지표조사시 기초자료로 활용될 수 있을 것으로 기대된다.

유리커튼월 수막시스템 분무헤드의 화재 실험 연구 (Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System)

  • 김성원;남지우;조성욱;유홍선;남준석;김동준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.31-40
    • /
    • 2016
  • 최근 초고층 건물 외벽에는 유리 커튼월 시스템이 많이 적용되고 있으며, 이러한 초고층 건물은 화재 발생 시 연돌효과 및 외부 기류에 따라 수직으로 화재가 급격하게 확산되는 특성을 가지고 있다. 기존에 사용되고 있는 스프링클러헤드는 상층부로의 화재 확산을 효과적으로 방지 할 수 없기 때문에 화재시 막대한 재산 및 인명피해를 초래한다. 따라서 본 연구에서는 보다 넓은 유리커튼월 면적을 방호할 수 있는 수막을 형성하고 층간 화재 확산을 방지 할 수 있는 수막 헤드를 개발하였다. 수막 헤드의 성능을 검증하기 위하여 살수 실험 장치를 구성하고 이를 활용하여 기존 스프링클러 헤드와 살수 패턴을 비교, 분석하였다. 상층부로의 화재 전파 차단 성능을 검토하기 위하여 2층 유리커튼월로 구성되어 있는 실험 장치를 활용하여 화재 실험을 수행하였다. 이를 통해 본 연구에서 제시한 수막 헤드가 기존 스프링클러헤드 보다 효과적으로 화염을 차단하는 것을 확인하였고 수치해석을 통해 최초 크랙 위치 및 파단 임계 온도를 분석하였다.