• Title/Summary/Keyword: Water circulation rate

Search Result 223, Processing Time 0.029 seconds

The Characteristics of Attrition of Absorbents for Pre-combustion CO2 Capture (연소 전 CO2 포집 흡수제들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Moon, Jongho;Park, Youngcheol;Jo, Sungho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.5
    • /
    • pp.428-436
    • /
    • 2013
  • Attrition characteristics of $CO_2$ absorbents for pre-combustion $CO_2$ capture were investigated to check attrition loss of those absorbents and to determine solid circulation direction and the better $CO_2$ absorbent. The cumulative attrition losses of two absorbents increased with increasing time. However, attrition loss under a humidified condition was lower than that under a non-humidified condition case. Between two absorbents, attrition loss of PKM1-SU absorbent was higher than that of P4-600 absorbent. The average particle sizes of the attrited particles were less than $2.5{\mu}m$ for two absorbents under a non-humidified condition case, and therefore, we could conclude that the main mechanism of attrition for two absorbents is not fragmentation but abrasion. Based on the results from the test for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor. Attrition loss and make-up rate of two absorbents were compared based on the results from $CO_2$ sorption capacity tests and attrition tests. Required make-up rate of P4-600 absorbent was lower than that of PKM1-SU absorbent. However, more detail investigation on the optimum regeneration temperature, manufacturing cost, solid circulation rate, regeneration rate, and long-term sorption capacity should be considered to select the best $CO_2$ absorbent.

Efficiency Tests of Seawater Exchange System for Enhancement of Seawater Quality (해수교환시스템의 수질향상 효율평가)

  • Jang, Chang-Hwan;Kim, Sang-Taek;Kim, Hyo-Seob;Kim, Kyu-Han;Song, Man-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.3
    • /
    • pp.206-215
    • /
    • 2010
  • The multi-outlets were installed on the existing seawater exchange breakwater in order to improve seawater exchange rate at Jumunjin harbor. Physical and numerical model system were fulfilled for 4 cases to evaluate seawater exchange system which is able to discharge water remotely. The seawater circulation pattern and seawater exchange rate in the harbor were compared and analyzed. Consequently, total seawater exchange rate for CASE 1 was calculated 48% due to the dead zones which hinder seawater circulation in the harbor. Otherwise, the seawater exchange rates of CASE 2, CASE 3, and CASE 4 with the installation of the system were enhanced 19%, 15% and 17%, respectively compare to CASE 1.

An estimation method for the maintenance timing of the infiltration trench (침투도랑 시설의 유지관리 시점 산정방법에 관한 연구)

  • Lee, Seung Won;Cha, Sung Min
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.29-35
    • /
    • 2020
  • To manage the non-point source pollution and restore the water circulation, many technologies including infiltration or reservoir systems were installed in the urban area. These facilities have many problems regarding maintenance as their operation period becomes lengthier. The purpose of this study was to estimate the optimal maintenance timing through a long-term load test on the infiltration trench as one of the low impact development techniques. An infiltration trench was installed in the demonstration test facility, and stormwater was manufactured by Manual on installation and operation of non-point pollution management facilities from the Ministry of Environment, Korea and entered into the infiltration trench. Particle size distribution (PSD), suspended solids (SS) removal efficiency, and infiltration rate change tests were performed on inflow and outflow water. In case of the PSD, the maximum particulate size in the outflow decreased from 64 ㎛ to 33 ㎛ as the operating duration elapsed. The SS removal efficiency improved from 97 % to 99 %. The infiltration rate changed from 0.113 L/sec to 0.015 L/sec during the operation duration. The maintenance timing was determined based on the stormwater runoff requirements with these changes in water quality and infiltration rate. The methodologies in this study could be used to estimate the timing of maintenance of other low impact development techniques.

A Study on Cooling Systems with Cold Water Panels in the Walls of Small Buildings (소형 건축 벽면의 냉수 패널에 의한 냉방시스템에 관한 연구)

  • Cho, Dong-Hyun;Jo, Myeong-Gi
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.20-26
    • /
    • 2019
  • This study was conducted on cooling systems in which, for the first time at home and abroad, cold water panels are embedded in the walls of small buildings for radiant cooling by heat absorption with cold water. In summer, cold water is circulated through cold water (chiller) circulation tubes embedded in three walls (two side walls and one rear wall) of a building to implement radiant cooling by the coldness of the water. From the results of this study, the experimental and theoretical natural convection heat transfer coefficients were relatively well-matched over the entire experimental range, thereby verifying the reliability of the experimental results. The surface temperature reduction rate of the walls in which cold water panels are embedded was large whereas that of the walls where no cold water panels are embedded was very small.

Ocean Current Power Farm Interaction Study (해양 조류발전단지 간섭 연구)

  • Jo, Chul-Hee;Yim, Jin-Young;Chae, Kwang-Su;Park, Ro-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.109-113
    • /
    • 2009
  • Several tidal current power plants are being planned and constructed in Korea utilizing the strong tidal currents along the west and south coasts. A tidal current reaches 9.7 m on the west coast; there are few potential regions for tidal current power generation. The construction of a dam to store water can prevent the circulation of water, causing a great environmental impact on the coast and estuary. The tidal barrage could produce a large amount of power, but it should be carefully considered. The purpose of developing renewable energies is to minimize the environmental impact and to maximize the utilization of clean energy. To produce a great quantity of power, tidal current farms require the placement of numerous units in the ocean. The power generation is very dependent on the size of the rotor and the incoming flow velocity. Also, the interactions between devices contribute greatly to the production of power. The efficiency of a power farm is estimated to determine the production rate. This paper introduces 3 D interaction problems between rotating rotors, considering the axial, transverse, and diagonal distances between horizontal axis tidal current devices.

A Study on Desulfurization and Denitrification of Flue Gas in Industry Boiler (산업용 보일러의 배연탈황 및 탈질에 관한 연구)

  • 이태호;정순형;정흥기
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.99-104
    • /
    • 1995
  • The objective of this study was to investigate the effect on denuclearization and decertification of flue gas by utilizing Mg( OH)$_{2}$ and NaOH as reagents in industrial boiler. We used packed absorber with Tellerette in all cases. And pH of circulation solution, rate of liquid per gas in absorber, COD concentration by pH variation in oxidation basin were inves- tigated. The following conclusions were obtained from experimental results: 1. Concerning running cost for reagents, Mg( OH)$_{2}$ reagent for treatment of flue gas was more economical than NaOH. 2. While Mg( OH )$_{2}$ and NaOH as absorbents were used, then the ratio of denuclearization was 96 and 97% respectively and nitrification was recorded 29 and 25% . 3. In this absorption tests the optimum condition for ratio of liquid per gas, pH and nonregenerable salt concentration of circulation solution were 3.6ℓ /Nm$^{3}$, 6.0, 0.5∼1.0% respectively, 4. Initial COD in oxidation basin was 800 ∼ 1,00099ut after adjusting to pH 7.0, COD of effluent water was less than 20ppm.

  • PDF

Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse (온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

Salinity Changes and Bottom Water Particle Exchange Simulations in Response to Sluice Gate Operations at Saemangeum Lake (새만금 배수갑문 운영에 따른 염분 변화와 저층수의 입자교환 모의)

  • Seonghwa Park;Jonggu Kim;Minsun Kwon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.562-575
    • /
    • 2023
  • In an effort to improve water quality, the South Korean government has implemented measures to increase seawater circulation in Saemangeum Lake. We analyzed the effect of increasing the frequency of seawater circulation based on salinity levels and bottom water exchange in the lake, using an environmental fluid dynamics code model. When the sluice gate opening and shutting frequency increased from once to twice per day, the internal water level of Saemangeum Lake increased by up to ~0.7 m. The salinity increased by 2.12 psu near the western breakwater and decreased by 1.18 psu near the freshwater inlet. We analyzed the extent of bottom water exchange using a particle tracing method and observed that the residual rate of particles shallower than 5 m in water depth decreased by 2.52% in Case 2 (opening and shutting twice per day) compared to Case 1 (opening and shutting once per day). This indicates that increasing the frequency of sluice gate opening and shutting would promote enhanced bottom water exchange. Consequently, the increased salinity and bottom water exchange associated with increased seawater circulation are expected to improve water quality in Saemangeum Lake.

Estimation of Environmental Characteristics for Deep Ocean Water Development Site Using Ecological Model (생태모델을 이용한 해상형 해양심층수 사업해역의 환경 특성 평가)

  • Kim, Dong-Myung
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.919-927
    • /
    • 2011
  • A ecosystem model was applied for understanding of circulation process of state variables in marine ecosystem. A mass balance was conducted by calculating the physical process. The sensitivity analysis was conducted to know which coefficient is the most effective factor to the state variables in the model. The results of the mass balance indicate that the primary production was 58.6 ton C/day in the case of mass flux. DIN and DIP in nutrient ingestion of phytoplankton were each 7.9 ton N/day, 1.1 ton P/day. POC and DOC in mineralization of organic matter were each 10.8 ton C/day, 40.6 ton C/day. The results of sensitivity analysis showed that the maximum growth rate of phytoplankton was the most important factor for overall state variables. In the case of nutrients, Half saturation constant of DIN, and mineralization rate of DOM for COD were important factor.

DEVELOPMENT OF A GRAIN CIRCULATING TYPE NATURAL AIR IN-BIN DRYER

  • Yun, H.S.;Chung, H.;Cho, Y.G.;Park, W.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.405-412
    • /
    • 2000
  • A natural air in-bin grain dryer with a grain circulator was developed for on farm use. Natural air drying test for rough rice was carried out to evaluate drying rate, uniformity of moisture content distribution in grain bed and energy consumption. It took 10 days to dry 8 ton of paddy rice from 21.9%(w.b) to 16.7%(w.b) moisture contents using the prototype dryer. The average drying rate was 0.52%/day. The uniformity of moisture content after drying was superior to the conventional natural air dryer where is grains were not circulated during drying periods. The dryer performance evaluation index was 738.3KJ/(kg.water), which was more effective than that of grain circulation t)pe hot air dryer(3,500-5,000 KJ/kg.water).

  • PDF