• Title/Summary/Keyword: Water and wastewater treatment facilities

Search Result 181, Processing Time 0.028 seconds

Element Technology and Strategy of Digital Twin in the Water Treatment (수처리공정의 디지털 트윈 요소기술과 추진 전략)

  • Young-Man Cho;Yong-Jun Jung
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Domestic water supply and sewage facilities are rapidly aging and maintenance difficulties such as aging of operation and management personnel are overlapping, so Digital Twin technology is attracting attention as an intelligent means of process management. Digital twin projects for domestic water treatment processes include the smart sewage treatment project promoted by the Ministry of Environment, projects independently promoted by some local governments, and digital twin purification plant projects promoted by K-water. However, the content of digital twin promotion is different for each institution. Therefore, in the water treatment process, technological standardization and step-by-step implementation methods for digital twins must be preceded to reduce trial and error in future business promotion. This study aims to provide an efficient promotion plan by prescribing the digital twin element technology and composition method in the water treatment process and reviewing the contents currently being promoted by the Ministry of Environment, local governments, and K-Water individually.

Characteristics of $SiO_2$ Scale Removal by Chemical Cleaning in Reverse Osmosis Membrane Process (역삼투막 공정에서 화학적 세정에 의한 $SiO_2$ scale 제거특성)

  • DockKo, Seok;Lee, Hyung-Jib
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Reverse osmosis (RO) membranes have been widely used for desalination as well as water and wastewater treatment facilities. Cleaning process is important to maintain stable operation as well as prevention of membrane fouling. Purpose of this research is to analyze electrostatistic and chemical characteristics after cleaning of RO membrane against $SiO_2$ scale. Four RO membranes of polyamide are used and examined about effect of chemical cleaning. EDTA (ethylene diamine tetraacetic acid) and SDS (sodium dodecil sulfate) and NaOH are applied for cleaning process after operation in synthetic water. Then, cleaning was performed with chemicals such concentration as 6hr, 12hr and 24hr, respectively. As a result, transmittances of FT-IR of four membranes are compared at each cleaning concentration. Ta/Tv shows difference of chemical composition between new membrane and cleaning membrane after cleaning. Type B of RO membrane is turned out to be most vulnerable to cleaning among four membranes. In terms of zeta potential, new membrane has -16 mV to +6 mV on pH while scaled membrane has -18 mV to 2 mV. However, it changed -23mV to 0.9 mV after cleaning. In comparison with existing salt rejection of RO membranes after cleaning, the rejection of the membranes goes down 0.7% maximum. Though cleaning changes the characteristics of membrane surface, it does not greatly affect salt rejection. pH is a critical factor to flux change in PA (polyamide) membrane.

Study on Energy Independence Plan and Economic Effects for Sewage Treatment Plant (하수처리시설의 에너지자립화 및 경제적 효과분석)

  • Park, Kihak;Lee, Hosik;Ha, Junsu;Kim, Keugtae;Lim, Chaeseung
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.2
    • /
    • pp.128-136
    • /
    • 2021
  • It is generally known that a wastewater treatment plant (WWTP) consumes immense energy even if it can produce energy. With an aim to increase the energy independence rate of WWTP from 3.5% in 2010 to 50% in 2030, the Korean government has invested enormous research funds. In this study, cost-effective operating alternatives were investigated by analyzing the energy efficiency and economic feasibility for biogas and power generation using new and renewable energy. Based on the US EPA Energy Conservation Measures and Korea ESCO projects, energy production and independence rate were also analyzed. The main energy consumption equipment in WWTP is the blower for aeration, discharge pump for effluent, and pump for influent. Considering the processes of WWTP, the specific energy consumption rate of the process using media and MBR was the lowest (0.549 kWh/㎥) and the highest (1.427 kWh/㎥), respectively. Energy-saving by enhancing anaerobic digester efficiency was turned out to be efficient when in conjunction with stable wastewater treatment. The result of economic analysis (B/C ratio) was 2.5 for digestive gas power generation, 0.86 for small hydropower, 0.49 for solar energy, and 0.15 for wind energy, respectively. Furthermore, it was observed that the energy independence rate could be enhanced by installing energy production facilities such as solar and small hydropower and reducing energy consumption via the replacement of high-efficiency operating.

The Development of the Waste Pneumatic Transportation System (진공식(眞空式) 쓰레기 파이프라인수송(輸送) System 개발(開發))

  • Park, Chung-Hyun;Kim, Bong-Geun;Kwon, Bong-kee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.3
    • /
    • pp.115-132
    • /
    • 1996
  • The present problems concerning the control of generation, storage, collection, transfer and transport, processing and disposal of the municipal waste are serious. And the transportation of the municipal waste is recently a important part of solid waste treatment and disposal. The waste pneumatic transportation system is expected to be an effective method for use in solving that problems. In this study, pneumatic transportation system was applied to 2,000-5,000 households of public/group housing for economic and technical analysis on the basis of data for working and operation. The proper equipment must be selected through economic and technical analysis for generation and properties of waste because the equipment in facilities of system is various. And the efficient operation method should be studied on the basis of information on the record of oeration. As the wet food waste clogs the pipeline, it is necessary to examine under the actual condition. The maximum unit waste generation rate based on the assumption that each household is comprised of 3.20 people is determined $2,340g/household{\cdot}day$, and it is included the 50% increase of seasonal and daily change.

  • PDF

A Study on Strengthening Option of T-N Effluent Water Quality Standards of Sewage Treatment Plants (하수처리시설의 T-N 방류수 수질기준 강화방안에 관한 연구)

  • Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.216-225
    • /
    • 2018
  • Over the past 40 years, the public sector has continued to invest in the sewage treatment plants (STPs) in Korea. Currently, the domestic sewage treatment rate is over 90% with the enhancement of operating efficiency of the STPs, and water quality of major rivers has been continuously improved. However, COD and T-N indicators are stagnating or slightly worsening, and though advanced treatment facilities are installed in most of the STPs, there is a limit to the removal of nutrients. Since there are a lot of water pollution sources in the vicinity of the watershed because of high population density in Korea, it is essential to reduce the inflow of the nutrients in order to prevent the eutrophication of the rivers and lakes. While the effluent T-P standard in STPs has greatly strengthened since 2012, which results in the considerable investment for the improvement of treatment process in STPs for the last few years, it is necessary to strengthen the T-N standards, as the effluent standard of T-N has been maintained at 20 mg/L since 2002. In this study, based on the analysis of the effluent T-N standard status of major industrialized countries, and the domestic nitrogen load in public waters, the option of appropriate T-N standard level is reviewed, and the required investment costs and the effect of strengthening the standard are estimated.

Detection of CTX-M and Clonal Analyses using MLST in Cefotaxime Resistant $Escherichia$ $coli$ Isolated from the Han-River, Korea

  • Son, Gun-Woo;Kim, Mal-Nam
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.4
    • /
    • pp.286-295
    • /
    • 2011
  • Bacteria resistant to various antibiotics have recently become an issue of the utmost importance. Resistant strains are not uncommon, even in municipal drinking water sources. The health threat posed by resistant, pathogenic bacteria has serious ramifications for both public health and agriculture. In this study, we isolated antibiotic resistant bacteria from water samples from the Han River, Korea, which is contaminated by the wastewater from many industrial complexes, hospitals, agricultural and animal husbandry estates, and from wastewater treatment facilities. We determined the degrees of resistance to various antibiotics exhibited by the isolated strains. The similarities between the isolated $E.$ $coli$ strains were examined, using the pulsed field gel electrophoresis and multilocus sequence typing, in order to trace their origins and to explore the syntechnic adaptations and pathogenicity of the various strains and relate these to their genetic sequence. A total of 25 $E.$ $coli$ strains were isolated from six stations along the Han River. All the 25 strains exhibited resistance to ampicillin. We also investigated resistance to amoxicillin, clavulanic acid, cefazolin, cofoxitin, cefotaxime, cefpodoxime, ceftriaxone, cefepime, nalidixic acid, aztreonam, ciprofloxacin, streptomycin, gentamicin, chloramphenicol and imipenem. Based on the ESBL detection, 14 strains belonged to the ESBL producing strains. The number of the clonal complex producing strains was 5 among the 14 isolated strains. The 5 strains were included in the 168, 23, 38, 469, 156 clonal complex, respectively. The rest 9 strains were not included in the clonal complex, but showed independent STs.

Urban Instream Flow Augmentation Using Reclaimed Water in Korea (하수처리수 재이용을 통한 도시하천 물순환 및 수질 개선)

  • Jee, Yong-Keun;Ahn, Jong-Ho;Lee, Jin-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.285-294
    • /
    • 2012
  • Current urban stream conditions and their restoration projects were investigated by surveying the urban stream management experts in 29 cities with high population density (more than 1,000person/$km^{2}$). The survey results showed that the ratio of covered urban streams decreased by 1.4% (from 14% to 12.6%) in the last 5 years through steady river restoration projects promoted by governments. Nonetheless, 36.3% of 369 urban streams surveyed still report stream depletion problems; therefore, more efforts to alleviate the problems caused by distorted water circulation of urban streams are still necessary. Water depletion in many local urban streams, unlike national rivers, is accelerated due to negligence in stream management, budget shortage, and other reasons. To prevent stream depletion, the use of reclaimed water is suggested as one of the prevention plans. When available amounts of reused sewage are estimated through actual available nationwide sewage discharges of each watershed and instream flow of stream, annual instream flow supply of 780 million $m^{3}$ is expected; 4.8% reduction in the pollution load of public sewer treatment facilities is expected; and the creation of new value through water reuse service is expected. Thus, it is important for the reviews of feasibility and alternatives of water reuse projects for flow augmentation to consider not only investment budget reductions, but also environmental aspects. Also it is necessary to provide the financial support of unified government with strict water quality management policy.

Evaluation of Particle Removal Rate in Inclined-pipe Settling System for Stormwater Infiltration (강우유출수의 침투시 부하저감을 위한 경사관 침전장치의 효율평가)

  • Kim, Sangrae;Kim, Dongkeun;Mun, Jungsoo;Han, Mooyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.719-726
    • /
    • 2009
  • One of the alternative runoff management measures is on-site runoff mitigation, such as rainwater retention tank and infiltration facilities especially the latter that is possible to manage simultaneously runoff quality and quantity as a perspective of water-cycle. This study was conducted to develop a particle separator, inclined-pipe settling system, that could improve particle removal efficiency of road runoff as a pre-treatment device of stormwater infiltration. Solid particles larger than $100{\mu}m$ are separated by simple sedimentation; however, the significant amount of pollutants with a diameter less than $100{\mu}m$ remain in suspension. Without any treatment in that case of the runoff into infiltrate, groundwater would be deteriorated and also infiltration rate would be decreased by clogging. Therefore, we suggest optimal design parameters (inclined angle, pipe length, and surface loading rate) of inclined-pipe settling system which can be designed to effectively remove particles diameter smaller then $70{\mu}m$. Thus, the results showed TSS removal efficiency more than 80% with a particle diameter between $20{\mu}m$ and $70{\mu}m$, 100% above particle diameter $70{\mu}m$ for the inflow rate $0.018 m^3/m^2{\cdot}hr$ with pipe inclined at angle $15^{\circ}$.

Application of HSPF Model for Effect Analyses of Watershed Management Plans on Receiving Water Qualities (유역관리에 따른 수질개선 효과분석을 위한 HSPF 모델 적용)

  • Song, Hye-Won;Lee, Hye-Won;Choi, Jung-Hyun;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.358-363
    • /
    • 2009
  • The HSPF (Hydrological Simulation Program-Fortran) model was applied to the Kyoungan stream watershed to analyze effects of watershed management plans on receiving water qualities. Utilizing BASINS 3.1 GIS program, the Kyoungan stream watershed was divided into 57 sub-basins and model input parameters were obtained, from DEM (Digital Elevation Model), land use type, stream map, and wastewater treatment facilities, etc.. The hydrologic module of the model was validated based on the measured meteorological data and stream flow data. Then the model was calibrated and verified against the field measurements of water qualities, including temperature, DO, BOD, $NO_3-N$, $NH_3-N$, Org-N, TN and TP. In most cases, there were reasonable agreements between measurements and predictions. The validated model was used to analyze the water quality improvements in the main stream of Kyoungan stream according to the watershed management plans in sub-basins, which are three different scenarios: water quality improvement in tributaries through watershed management activities, expansion and up-grade of wastewater treatment plants, and application of first and second scenarios together. It was concluded that expansion and upgrade of wastewater treatment plants would be more effective than watershed management activities. In order to improve water qualities to the satisfactory level, both watershed management and point source control must be required in the Kyoungan stream.

Status of Anaerobic Digestion Facility for Pig-slurry in Korea (국내 가축분뇨 혐기소화시설 현황 및 운영실태 분석)

  • Jeong, Kwang-Hwa;Kim, Jung-Gon;Han, Duk-Woo;Kwag, Jung-Hun
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • This study was conducted to survey and inspect the currently operating anaerobic digestion facilities for animal manure. Recently, the number of anaerobic digestion facility for livestock manure is on the rise thanks to growing interest in developing alternative energy. A anaerobic digestion system has been constructed in large scale farms or animal manure public resource center. Currently, most animal manure anaerobic digestion facilities in operation are producing biogas from the pig slurry which contains 97% water. Methane gas can be used to operate a engine generator which then produces electricity. Anaerobic digestate, a by-product of digestion, is mostly utilized as a liquid fertilizer after curing processing. Only in a few cases, it can be discharged after wastewater treatment process. The problem of anaerobic digestate treatment is the imbalance of C/N ratio. The content of N was too high to keep it into normal process.