• Title/Summary/Keyword: Water allocation

Search Result 250, Processing Time 0.022 seconds

Parallel Reservoir Analysis of Drought Period by Water Supply Allocation Method (공급량 배분기법을 이용한 갈수기 병렬저수지 해석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2006
  • In this study, an optimization technique was developed from the application of allocation rule. The results obtained from the water supply analysis and reliability indices analysis of Andong dam and Imha dam which are consist of parallel reservoir system are summarized as the followings; Allocation rule(C) is effective technique at the parallel reservoir system because results of the water supply analysis, storage analysis and reliability indices analysis is calculated reasonable results. Also, reliability indices analysis results are not sufficient occurrence based reliability or quantity based reliability. Thus reliability indices analysis are need as occurrence based reliability, quantity based reliability vulnerability, resilience, average water supply deficits and average storage. And water supply condition is better varying water supply condition than constant water supply condition.

Waste Load Allocation of Hwanggujicheon Watershed Using Optimization Technique (최적화기법을 이용한 황구지천유역의 오염부하량 할당)

  • Cho, Jae Heon;Chung, Wook Jin;Lee, Jong Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.728-737
    • /
    • 2005
  • Water quality of the Hwanggujicheon is poor because of the rapid housing and development in the large area of the basin. Establishment of water quality management strategy, based on the pollution sources survey and pollutant loads estimation, has to be established for the preservation of the stream water quality of the region. In this study, waste load allocation model to achieve the water quality goal of the stream and the optimization of pollutant load reduction, was developed. Nonpoint pollutant loads calculated by runoff model in the previous study are utilized for pollutant loads estimation of the drainage areas in this study. From the application result of the allocation model, water quality goals of the Hwanggujicheon that can be achieved as a matter of fact are BOD 8 mg/L. To achieve these goals, 23% of effluent BOD loads have to be reduced in the basin.

Excessive State of Pollutant Load Allocation and Penalty Application Schemes based on Pollutant Reduction Plan Types for Solving Excessive Problem of Allocation (오염할당부하량의 초과현황 및 초과해소를 위한 삭감계획 유형에 따른 페널티 적용방안)

  • Park, Jae Hong;Park, Bae Kyoung;Oh, Seung Young;Hwang, Ha Sun;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.66-73
    • /
    • 2013
  • Total Maximum Daily Loads (TMDLs) system was introduced to manage pollution load of watershed and to improve water quality of unit watershed so that it is possible to protect dringking water soureces. Load allocation observation is the most important factor in TMDLs system. Because if load allocation is not observed, it is difficult to achieve water quality goal of unit watershed. Also it is impossible to improve water quality of the drinking water sources. Therefore it is necessary to apply some kind of sanctions (penalty) in case of excess of load allocation. The sanctions have to be, however, applied differently based on various reduction plan types, i.e., using the reduction load planed in 2nd phase, delay the completion, additional reduction in 2nd phase, error of the pollution sources, etc. Moreover, the penalty load should be properly imposed, lest it should be overburden the provence. The reduction load trade inter province must be restrictively permmitted only the same unit watershed.

The Capability Analysis of Water Supply for the Parallel Reservoir System by Allocation Rules (저수량 배분규칙을 적용한 병렬저수지 용수공급능력 해석)

  • Park, Ki-Bum;Jee, Hong-Kee;Lee, Soon-Tak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.215-224
    • /
    • 2007
  • The purpose of this study was to estimates water supply reliability indices of the water supply by Allocation Rules(AR) for parallel reservoirs. Rule (A) can be considered it as only current storage, Rule(B) can be considered it as current storage and inflow and Rule(C) can be considered it as current storage, inflow and water supply capacity. First, conditions of water supply are divided by Condition I for the monthly constant water supply and Condition II for the monthly varied water supply. Second, results of allocation coefficients are revealed the smallest different at Rule(C). The analysis of water supply showed that the capability of water supply is superior to the Rule(B), it is superior to the Rule(C) on the base of the balance of water supply. The reliability analysis was highly showed at the Rule(B) and Rule(C). A methodology for the analysis of water supply was developed and applied to the parallel reservoir system from this research, The operation rule for the parallel reservoir can be slightly modified and successfully applied to the different kinds of the parallel reservoir system.

Water Allocation by Estimation of Damage Function in a Water-Deficit Situation (피해함수 산정을 통한 물 부족 상황에서의 용수배분 방안)

  • Yi, Choong-Sung;Park, Kyo;Choi, Seung-An;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.431-440
    • /
    • 2006
  • Recently, water conflicts are rapidly increasing and more serious. So, it needs to establish the reasonable water allocation rules and criteria. This study aims at performing inter-sectoral water allocation with a focus on economic effciency and social utility. To allocate water among the sectoral water uses, water shortage damage functions were estimated and then converged to the utility functions. Finally, each sectoral water uses are allocated by applying 'law equimarginal utility' to maximize social utility. Also weighting factor which reflects scale and characteristic of water demand in a region was estimated to perform the inter-regional water allocation. The water allocation rule was applied to the future water-deficit situation in Han-river basin. As a result, domestic water use was allocated more sufficient agricultural and industrial water use. Also, the water shortage occurs severely in the rural area like Gangwon-do because of its low urbanization and industrialization. This study suggests a alternative view of the economic water allocation which have difficulty under water supply mechanism in Korea.

The Allocation Methods for Economical Efficiency Using an Optimized Model (최적화 모델을 이용한 경제적인 총량관리 할당기법 연구)

  • Choi, In Uk;Shin, Dong Seok;Kim, Hong Tae;Park, Jae Hong;Ahn, Ki Hong;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • In Korea, Total Maximum Daily Loads(TMDLs) has been enforced to restore and manage water quality in the watersheds. However, some assesment of implementation plan of TMDLs showed that the achievement of the target water quality is not related to the proper allocation loads because difference of flow duration interval. In the United States, the discharge loads are determined by water quality modeling considering standard flow conditions according to purpose. Therefore, this study tried to develop the allocation method considering economical efficiency using water quality model. For this purpose, several allocation methods being used in the management of TMDLs is investigated and develope an allocation criteria considering regional equality and uniformity. Since WARMF(Watershed Analysis Risk Management Framework) model can simulate the time varying behavior of a system and the various water quality variables, it was selected for a decision support system in this study. This model showed fairly good performance by adequately simulating observed discharge and water quality in Miho watershed. Furthermore, the scenario simulation results showed that the effect of annual average water quality improvement to remove 1kg BOD is more than 25 times, even if point pollutants treatment facility is six times more expensive to operate than non-point pollutants treatment facility.

Mathematical Model of Aquaculture Facility Utilization (양식장 이용에 대한 수학적 모형)

  • Eh, Youn-Yang
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.2
    • /
    • pp.444-454
    • /
    • 2014
  • The range of optimization problem in aquaculture is very wide, resulting from the range of species, mode of operation. Quite a few studies focus marine net-cages, but studies on land based culture farm are few or no. This paper considers a allocation problem to meet production planning in land based aquaculture system. A water pool allocation model in land based aquaculture system was developed. The solution finds the value of decision variable to minimize yearly production costs that sums up the water pool usage cost and sorting cost. The model inputs were (1) the fish growth rate (2) critical standing corp (3) number of water pool (4) number of fish. The model outputs were (5) number of water pool in growing phase (6) cost of cultivation (6) optimal facility allocation(number of water pool for each growing phase). To solve the problem, an efficient heuristic algorithm based on a greedy manner is developed. Branch and bound and heuristic is evaluated through numerical examples.

Water Allocation through Compensation between the Upper and Lower Basins (상·하류간의 자발적 보상을 통한 수자원의 합리적 이용방안)

  • Kim, Chong Won
    • Environmental and Resource Economics Review
    • /
    • v.13 no.3
    • /
    • pp.367-385
    • /
    • 2004
  • This study offers the possibility of water allocation between upstream and downstream regions by side payment. In the case of river water, water use of an upstream region affect a downstream region's water use but not vise versa. In this case, the downstream region wants to secure stable water by suggesting side payment to the upper region. We examine the maximum compensation of the downstream region for acquiring additional water. Also we compare each region's total benefits between the cases with and without cooperation. The result of empirical study show that there was a Pareto improvement when two region cooperate in the water use. Also the amount of side payment depend on the degree of shortage of water and both regions are satisfied with the water allocation result by voluntary negotiation.

  • PDF

Joint Subcarrier Matching and Power Allocation in OFDM Two-Way Relay Systems

  • Vu, Ha Nguyen;Kong, Hyung-Yun
    • Journal of Communications and Networks
    • /
    • v.14 no.3
    • /
    • pp.257-266
    • /
    • 2012
  • A decode-and-forward two-way relay system benefits from orthogonal frequency division multiplexing (OFDM) and relay transmission. In this paper, we consider a decode-and-forward two-way relay system over OFDMwith two strategies: A joint subcarrier matching algorithm and a power allocation algorithm operating with a total power constraint for all subcarriers. The two strategies are studied based on average capacity using numerical analysis by uniformly allocating power constraints for each subcarrier matching group. An optimal subcarrier matching algorithm is proposed to match subcarriers in order of channel power gain for both transmission sides. Power allocation is defined based on equally distributing the capacity of each hop in each matching group. Afterward, a modified water-filling algorithm is also considered to allocate the power among all matching groups in order to increase the overall capacity of the network. Finally, Monte Carlo simulations are completed to confirm the numerical results and show the advantages of the joint subcarrier matching, power allocation and water filling algorithms, respectively.

Developing an Optimization Module for Water, Energy, and Food Nexus Simulation

  • Wicaksono, Albert;Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.184-184
    • /
    • 2017
  • A nation-wide water-energy-food (WEF) nexus simulation model has been developed by the authors and successfully applied to South Korea to predict the sustainability of those three resources in the next 30 years. The model was also capable of simulating future scenarios of resources allocation based on priority rules aiming to maximize resources sustainability. However, the process was still relying on several assumptions and trial-and-error approach, which sometimes resulted in non-optimal solutions of resources allocation. In this study, an optimization module was introduced to enhance the model in generating optimal resources management rules. The objective of the optimization was to maximize the reliability index of resources by determining the resources' allocation and/or priority rules for each demand type that accordingly reflect the resources management policies. Implementation of the optimization module would result in balanced allocation and management of limited resources and assist the stakeholders in deciding resources' management plans, either by fulfilling the domestic production or by global trading.

  • PDF