• Title/Summary/Keyword: Water Vapor

Search Result 1,656, Processing Time 0.04 seconds

Comparative Water Relations of Two Vitis vinifera Cultivars, Riesling and Chardonnay

  • Park, Yong-Mok
    • The Korean Journal of Ecology
    • /
    • v.24 no.4
    • /
    • pp.223-226
    • /
    • 2001
  • The leaf water relations and photosynthetic rate during acute soil drying were compared in potgrown grapevine cultivars, Vitis vinifera cv. Chardonnay and V. vinifera cv. Riesling. Leaf water potential in Riesling decreased significantly from day 2 after water had been withheld, while in Chardonnay leaf water potential for the water-stressed plants was almost identical with that in well watered plants during the first 4 days. Higher stomatal conductance and photosynthetic rate in Chardonnay than Riesling were observed until day 3 after withholding water. Photosynthetic rate in water-stressed Chardonnay was not different from that in control plants until day 3 after withholding water, while that in water-stressed Riesling was reduced markedly from day 2. In Riesling, osmotic potential at turgor loss point was not changed irrespective of watering conditions. However, in Chardonnay osmotic potential at turgor loss point decreased more in the water stressed conditions than in well watered conditions. The osmotic adjustment in Chardonnay under water stress conditions must contribute to the maintenance of higher stomatal conductance and photosynthetic rate than those in Riesling for a significant period of the drying process. Though difference in stomatal conductance between the two cultivars was shown in the process of soil drying, stomatal conductance of both cultivars responded to vapor pressure difference between leaf and ambient air, rather than soil water status and leaf water potential.

  • PDF

Effect of Coating Methods on the Properties of Poly(lactide)-coated Paperboard: Solution Coating vs. Thermo-compression Coating

  • Rhim, Jong-Whan
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1155-1160
    • /
    • 2009
  • Poly(lactide) (PLA)-coated paperboards were prepared by solution coating and thermo-compression coating methods and their effect of coating on the packaging properties such as tensile, water resistance, water vapor barrier, and heat sealing properties was tested. Compared with uncoated control paperboard, tensile strength (TS) of PLA-coated paperboard increased profoundly (2.2-2.6 folds) with slight increase in elongation at break (E). Water absorptiveness (WA) of the paperboard decreased 74-170 folds and water vapor permeability (WVP) decreased 6.3-22.1 folds by coating with PLA, which indicates an increase in the hydrophobicity of the surface of paperboard. Compared with polyethylene (PE)-coated paperboard, both PLA-coated paperboard exhibited 2.3 time higher heat sealing strength. In addition, the PLA-coated paperboards showed equal or higher wet TS than PE-coated paperboard. All the test results showed that the paperboard coated by the thermo-compression coating method was similar to or better than those of coated by the solution coating method.

Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets (액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석)

  • Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

건축사의 필수응용 물리학(4)

  • Sin, Hyeong-Beom
    • Korean Architects
    • /
    • v.3 no.9 s.9
    • /
    • pp.17-22
    • /
    • 1968
  • An air in the atmosphere is acting constantly without letup. In the air contains not only various kinds of harmful and harmless elements but also always water vapor. In propotion to temperature this vapor transforms atmospheric phenomena. Let's use the air in accordance with various uses in reasonable regulation.

  • PDF

An Theoretical study on Spalling Mechanism of Concrete (콘크리트 폭렬발생 메카니즘에 관한 이론적 고찰)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kim, Gyeong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.422-427
    • /
    • 2008
  • The major cause of Concrete Spalling at high temperatures can be divided into the Vapor Pressure Rising, caused by the increase in free water temperature within the concrete, and Pore Pressure Rising induced by the vapor moving into dense pores within the concrete. Although the occurrence of spalling within concrete caused by these pressure increases can be assessed experimentally, a close examination into Mechanistic influence against various spalling factors shall be carried out first by using Mathematical Modeling and Theoretical Equations. The Spalling Prospect Process by theoretical mechanism is expedited in order of the following; selection of heating condition (fire strength and flame heating direction), a selection of constituent elements, an analysis of heat transmission, an analysis of moisture movement, distribution of water content, an analysis of pore/vapor pressure, and assessment of spalling occurrence.

  • PDF

Electrical Measurement of SOx Dew Point (SOx노점의 전기적 측정)

  • Chun, Y.N.;Yong, K.J.;Chae, J.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.600-610
    • /
    • 1995
  • When combustion gas is cooled down below the dew point of sulfuric acid vapor in the heat recovery systems, condensation occurs. Since the condensed sulfuric acid solution causes low-temperature corrosion in materials, it is important to measure the SOx dew point by electric measurement. In this study, two kinds of probes having electric gaps of 1mm or 2mm were used. and experiments were carried out by the parameters of sulfuric acid vapor and water vapor concentration. The changes of electric current caused by sulfuric acid condensed on the surface of probe according to the cooling rate and the probe head surface temperature were sudied. The opimum cooling rate was decreased with the increasing of water vaper concentration regardless of sulfuric acid concentration. The sensitivity of electric current is improved for the narrower gap(1mm) of ring electrodes, but it rarely affects the SOx dew point measuring of different probes according to the change of cooling rate.

  • PDF

A study on the Characteristics of Urban Dryness in Busan (부산의 도시건조화 특성에 관한 연구)

  • Park, Myung-Hee;Lee, Joon-Soo;Suh, Young-Sang;Han, In-Seong;Lee, Hye-Hyun;Kim, Hae-Dong;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1851-1862
    • /
    • 2014
  • It is well known that urban relative humidity has continuous decreasing trend owing to the influence of urbanization. The change of relative humidity is directly influenced by two factors, namely, temperature effect and water vapor effect in various urban effects. In this study, the temperature and the water vapor effects on the relative humidity change were analyzed by using monthly mean relative humidities for a long period(1961~2013) in Busan and Daegu. The major results obtained in this study can be summarized as follows. Firstly, the urban dryness was caused mainly by water vapor effect in summer. But, for the other seasons, the urban dryness is mainly due to the temperature effect. Secondly, the relative humidity in Busan is on the decrease until now. This phenomenon is similar to another Korean huge cities such as Seoul, Daejeon and Incheon.

Gas and Lipid Permeabilities and Biodegradability of Poly(3-Hydroxybutyric Acid)/Chitosan Blend Film (Poly(3-Hydroxybutyric Acid)와 Chitosan 블렌드 필름의 기체 투과도, 유지 투과도 및 생분해도)

  • 김미라
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.7
    • /
    • pp.1224-1229
    • /
    • 2004
  • The blend films of poly(3-hydroxybutyric acid) (PHB) with chitosan were prepared and water vapor transmission rate, oxygen permeability and lipid permeability of the PHB/chitosan films were measured. Additionally, the biodegradability of the PHB/chitosan films was also evaluated. Water vapor transmission rate and oxygen permeability of the films decreased by the addition of chitosan. The addition of polyethylene glycol (PEG, plasticizer), however, increased the water vapor transmission rate and oxygen permeability of the films. In the evaluation of lipid permeability, all the films except PHB (the film made of only PHB) and PHB-P (the film made of PHB and PEG) did not permeate beef tallow for 24 hours. The consumed oxygen for PHB/chitosan films during incubation was greater than that for the control on the biodegradability determination of the films, which implies that PHB/chitosan films were degraded by the microorganisms. The higher PHB ratio of the films was, the faster biodegradation of the films occurred.

Water Vapor Adsorption and Hydrogen Peroxide Decomposition on Date Pit Carbonization Products

  • Youssef, A.M.;El-Nabarawy, Th.;Ahmed, S.A. Sayed;Rashwan, W.E.
    • Carbon letters
    • /
    • v.6 no.4
    • /
    • pp.227-233
    • /
    • 2005
  • Carbonization products C1, C2, C3, C4 and C5 were prepared by the carbonization of date pit in limited air, at 500, 600, 700, 800 and $1000^{\circ}C$, respectively. C1-V-600, C3-V-600, C1-V-1000 and C3-V-1000 were prepared by thermal treatment of C1 and C3 under vacuum at 600 and $1000^{\circ}C$. The textural properties were determined from nitrogen adsorption at 77 K and from carbon dioxide adsorption at 298 K. The surface pH, the FTIR spectra and the acid and base neutralization capacities of some carbons were investigated. The amounts of surface oxygen were determined by out-gassing the carbon-oxygen groups on the surface as $CO_2$ and CO. The adsorption of water vapor at 308 K on C1, C2, C3 and C4 was measured and the decomposition of $H_2O_2$ at 308 K was also investigated on C1, C2, C3, C4 and C5. The surface area and the total pore volume decreased with the rise of the carbonization temperature from 500 to $1000^{\circ}C$. The adsorption of water vapor is independent on the textural properties, while it is related to the amount of acidic carbon-oxygen groups on the surface. The catalytic activity of $H_2O_2$ decomposition does not depend on the textural properties, but directly related to the amount of basic carbon-oxygen complexes out-gassed as CO, at high temperatures.

  • PDF

Characteristics of Infrared and Water Vapor Imagery for the Heavy Rainfall Occurred in the Korean Peninsula (한반도에서 발생하였던 집중호우 시 적외 및 수증기 영상의 특성)

  • Seong, Min-Gyu;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.465-480
    • /
    • 2014
  • In this study, we analyzed the spatio-temporal variations of satellite imagery for the two heavy rainfall cases (21 September, 2010, 9 August, 2011) occurred in the Korean Peninsula. In general, the possibility of strong convection can be increased when the region with plenty of moisture at the lower layer overlapped with the boundary between dark and bright area in the water vapor imagery. And the merging of convective cells caused by the difference in the moving velocities of two cells resulted in the intensification of convective activity and rainfall intensity. The rainfall intensity is more closely linked with the minimum cloud top temperature than the mean cloud top temperature. Also the spatio-temporal variations of rainfall intensity are impacted by the existence of merging processes. The merging can be predicted by the animation of satellite imagery but earlier detection of convective cells is almost impossible by using the infrared and water vapor imagery.