• 제목/요약/키워드: Water Tank Model

검색결과 520건 처리시간 0.027초

배수문에서 실내모형실험에 의한 무동력 토사제거시스템의 수리 특성 (Hydraulic Characteristics of the Non-power Soil Cleaning and Keeping System by the Large-Scale Model Test at the Dike Gate)

  • 박찬근;오범환;이달원
    • 한국농공학회논문집
    • /
    • 제56권5호
    • /
    • pp.67-75
    • /
    • 2014
  • In this study, the large-scale hydraulic model test was performed to investigate the hydraulic characteristics for development of the non-power soil cleaning and keeping system at the dike gate. The outlet height, outflow number, outflow discharge, and outflow cycle were compared and analyzed. The non-power soil cleaning and keeping system was most effective at 11.2 mm in the outlet height. And then the mean outflow cycle was 1.09 sec, and the mean outflow discharge was $0.00164m^3/s$. The total outflow number increased gradually as the water level of a water tank increased, and the outlet height decreased. As a level of water tank decreased, the mean outflow cycle was lengthened, and the unit outflow discharge increased. This result showed this system was most effective. To remove the silty clay deposited in facilities, the methods of excavation, dredging, high pressure washing, etc have been applied to the tidal facilities such as land reclamation, a small size fishing port, and a harbor for maintenance. However, this is extremely cost-ineffective, whereas the non-power soil cleaning and keeping system will bring about an enormously positive economic effect. In addition, when the non-power soil cleaning and keeping system is applied to the dike gate of land reclamation, a thorough examination of the local tidal data and the careful system planning are required to prevent the disaster damage caused by flooding.

지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석 (Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank)

  • 윤장혁;강태원;양현익;전종수
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.

웨스팅하우스형 원자력발전소 가압기 방출 탱크의 실시간 시뮬레이션을 위한 전문모델 개발 (Development of a Dedicated Model for a Real-Time Simulation of the Pressurizer Relief Tank of the Westinghouse Type Nuclear Power Plant)

  • 서재승;전규동
    • 한국시뮬레이션학회논문지
    • /
    • 제13권2호
    • /
    • pp.13-21
    • /
    • 2004
  • The thermal-hydraulic model ARTS which was based on the RETRAN-3D code adopted in the domestic full-scope power plant simulator which was provided in 1998 by KEPRI. Since ARTS is a generalized code to model the components with control volumes, the smaller time-step size should be used even if converged solution could not get in a single volume. Therefore, dedicated models which do not force to reduce the time-step size are sometimes more suitable in terms of a real-time calculation and robustness. In the case of PRT(Pressurizer Relief Tank) model, it is consist of subcooled water in bottom and non-condensable gas in top. The sparger merged under subcooled water enhances condensation. The complicated thermal-hydraulic phenomena such as condensation, phase separation with existence of non-condensable gas makes difficult to simulate. Therefore, the PRT volume can limit the time-step size if we model it with a general control volume. To prevent the time-step size reduction due to convergence failure for simulating this component, we developed a dedicated model for PRT. The dedicated model was expected to provide substantially more accurate predictions in the analysis of the system transients. The results were resonable in terms of accuracy, real-time simulation, robustness and education of operators, complying with the ANSI/ANS-3.5-1998 simulator software performance criteria and RETRAN-3D results.

  • PDF

배수관망의 잔류염소 평활화를 위한 최적 재염소 처리 (Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems)

  • 윤재흥;오정우;최영송
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

Fault Detection and Diagnosis of the Deaerator Level Control System in Nuclear Power Plants

  • Kim Kyung Youn;Lee Yoon Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.73-82
    • /
    • 2004
  • The deaerator of a power plant is one of feedwater heaters in the secondary system, and it is located above the feedwater pumps. The feedwater pumps take the water from the deaerator storage tank, and the net positive suction head(NSPH) should always be ensured. To secure the sufficient NPSH, the deaerator tank is equipped with the level control system of which level sensors are critical items. And it is necessary to ascertain the sensor state on-line. For this, a model-based fault detection and diagnosis(FDD) is introduced in this study. The dynamic control model is formulated from the relation of input-output flow rates and liquid-level of the deaerator storage tank. Then an adaptive state estimator is designed for the fault detection and diagnosis of sensors. The performance and effectiveness of the proposed FDD scheme are evaluated by applying the operation data of Yonggwang Units 3 & 4.

하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석 (CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO)

  • 조성환;이종현;김대영
    • 방사성폐기물학회지
    • /
    • 제18권2_spc호
    • /
    • pp.327-336
    • /
    • 2020
  • HANARO (High-flux Advanced Neutron Application Reactor)는 우라늄의 핵분열 연쇄반응에서 생성된 중성자를 이용하여 다양한 연구개발을 수행하는 열출력 30 MW 규모의 연구용 원자로이다. 탈기탱크는 HANARO의 부속시설에 설치되어 있다. 탈기탱크는 내부환경요인으로 인해 기체오염물질을 발생시킨다. 탈기탱크는 기체오염물질을 허용 가능한 수준 이하로 유지하기위해 필요하며 기체시료채취판넬의 분석기에 의해 모니터링 된다. 응축수가 발생하여 기체시료채취판넬의 분석기 내부로 유입된다면, 분석기의 측정 챔버 내부에 부식이 발생하여 고장을 야기한다. 응축수의 생성 원인은 탈기탱크에 존재하는 기체가 분석기로 유입되는 과정에서 탈기탱크와 분석기사이 온도 차이다. 응축수 생성을 억제하고 계통 내부에 생성된 응축수를 효율적으로 제거하기 위해 탈기탱크와 기체시료채취판넬 사이에 히팅시스템이 설치되었다. 이 연구에서 우리는 히팅시스템의 효율성을 알고자 한다. 또한 Wall Condensation Model을 이용하여 유체 입구온도, 외부온도 및 히팅 케이블 설정온도 변화에 따른 파이프 온도와 평균응축량의 변화를 모델링하였다.

수조모델에 의한 접지전극의 형상계수추정 (Shapes Factor Estimation of Grounding Electrode by Water Tank Model)

  • 고희석;최종규;지봉호;이현무;김주찬;이충식;박규홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.365-367
    • /
    • 2001
  • We are explaining shapes factor of ground electrode in a rectangular parallelepiped which is based on analysis of a hemisphere electrode. Actually, a hemisphere electrode is hardly used in a plan and construction, because it is difficult for somebody to use one. This thesis describes the method of grounding resistance estimation which is used the water tank model and electrode shopes factor.

  • PDF

수조모델 실험에 의한 각판상 접지극의 해석 (Analysis of The Grounding Plate Electrodes by Water tank model Experiment)

  • 고희석;이충식;최종규;이현무;김주찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.39-41
    • /
    • 2003
  • In this paper, we examine theory of literature announced recently. At the same time. analysis a special quality of the Grounding Plate Electrodes that is laid under the ground to homogeneity earth by Dwight way that is announced in existing and then examined through analysis of theory Value and resistance Value of water tank model experiment Value.

  • PDF

수조식 양식장의 태양광발전시스템 리모델링 교체 효과: 시뮬레이션을 통한 에너지절감효과 분석 (The Effect of Remodeling Replacement of Photovoltaic Power Generation System in Fish Farm : Analysis of Energy Saving Effect through Simulation)

  • 최현석;나종혁;이현영;노재엽
    • Current Photovoltaic Research
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2021
  • In the past, marine pollution caused by radioactivity and wastewater discharge caused mass destruction. As an alternative, the land farming system became common and operational. In recent years, safety and environmental problems caused by declining population due to aging of fishermen and underdeveloped facilities have always been lurking, so improvement is urgently needed. As part of the new renewable energy 3020 plan announced by the government in 2017, a new model was proposed to improve the environment as well as save energy when the roof of a water tank farm was remodeled into a solar power system. Study, when the existing roof was remodeled and replaced with a water tank farm in Busan as an empirical model, the energy saving rate was analyzed by comparing the actual electricity consumption and power generation.

인공지능기법을 이용한 홍수량 선행예측 모형의 개발 (Development of a Runoff Forecasting Model Using Artificial Intelligence)

  • 임기석;허창환
    • 한국환경과학회지
    • /
    • 제15권2호
    • /
    • pp.141-155
    • /
    • 2006
  • This study is aimed at the development of a runoff forecasting model to solve the uncertainties occurring in the process of rainfall-runoff modeling and improve the modeling accuracy of the stream runoff forecasting, The study area is the downstream of Naeseung-chun. Therefore, time-dependent data was obtained from the Wolpo water level gauging station. 11 and 2 out of total 13 flood events were selected for the training and testing set of model. The model performance was improved as the measuring time interval$(T_m)$ was smaller than the sampling time interval$(T_s)$. The Neuro-Fuzzy(NF) and TANK models can give more accurate runoff forecasts up to 4 hours ahead than the Feed Forward Multilayer Neural Network(FFNN) model in standard above the Determination coefficient$(R^2)$ 0.7.