• Title/Summary/Keyword: Water Sensor

Search Result 1,228, Processing Time 0.032 seconds

Design of the Rain Sensor using a Coaxial Cavity Resonator (동축 공동 공진기를 이용한 물방울 감지 센서 설계에 관한 연구)

  • Lee, Yun-Min;Kim, Jin-Kook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.223-228
    • /
    • 2018
  • In this paper the water sensor using a coaxial cavity resonator is designed and manufactured. The water sensor which can sense water drop linearly has been constructed with voltage controlled oscillator(VCO), coaxial cavity resonator, RF switch, RF detector, A/D converter, DAC and micro controller. The operating frequency range of the designed water sensor is from 2.5GHz to 3.2GHz and the input voltage and current source are 24[V/DC] and 1[A]. The designed sensor circuit includes VCO, RF switch, RF detector which varies the frequency characteristics of the devices in the high frequency of 3GHz. And so we should correct the error of the frequency characteristics of those devices in the sensor circuit. To do this, we make the reference path which switches the signals to the RF detector directly without sending it to the resonator. According to the result of simulation and measurement, we can see that there is 0-50MHz difference between simulated resonator frequency and manufactured resonator frequency.

Android Remote Monitoring System of Ballast Water Treatment System (선박 평형수 처리 시스템의 안드로이드 원격 모니터링 시스템)

  • Choi, Hwi-Min;Seo, Ji-No;Lee, Kwang-Seob;Kim, Seon-Jong;Kim, Joo-Man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.217-224
    • /
    • 2015
  • In this paper, I describe a system for remote monitoring of devices Android-based sensor data recorded during the operation of the ballast water treatment system. The proposed remote monitoring system is Designed and implemented when a problem occurs in the ballast water treatment system installed in the vessel, provide information if you are unable to determine the cause in the field or engineer dispatch request of external. System developed is composed of a server holding the sensor data information collected from the vessel and a mobile device that is not bound to time and place. The transmission of sensor data between mobile devices and server, and is implemented by TCP/IP to transmit information securely. System is composed of request to the server from the mobile device after the user inputs the input values, to transmit the sensor data. The device provides the information of the sensor with a high level of importance to the user. Through the remote monitoring sensor information of the ballast water treatment system, the system is made to predict the failure of the sensor.

The Effect of the Deformation on the Sensitivity of a Flexible PDMS Membrane Sensor to Measure the Impact Force of a Water Droplet (액적의 충격력 측정을 위한 유연 멤브레인 센서의 PDMS 변형에 의한 민감도의 영향)

  • Kang, Dong Kwan;Lee, Sangmin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.16-21
    • /
    • 2022
  • This study investigates the effect of the deformation on the sensitivity of a flexible polydimethylsiloxane (PDMS) membrane sensor. A PDMS membrane sensor was developed to measure the impact force of a water droplet using a silver nanowire (AgNW). The initial deformation of the membrane was confirmed with the application of a tensile force (i.e., tension) and fixing force (i.e., compressive force) at the gripers, which affects the sensitivity. The experimental results show that as the tension applied to the membrane increased, the sensitivity of the sensor decreased. The initial electrical resistance increased as the fixing force increased, while the sensitivity of the sensor decreased as the initial resistance increased. The movement of the membrane due to the impact force of the water droplet was observed with a high-speed camera, and was correlated with the measured sensor signal. The analysis of the motion of the membrane and droplets after collision confirmed the periodic movement of not only the membrane but also the change in the height of the droplet.

An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR) (고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구)

  • Lee, Seung-Yeop;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.59-60
    • /
    • 2021
  • The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

  • PDF

Reduction Chattering Error of Reed Switch Sensor for Remote Measurement of Water Meter (Reed Switch 센서를 이용한 원격 검침용 상수도 계량기에서 Chattering 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kwon, Jong-Won;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.377-379
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors used for automatic remote measurement of water supply system, a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used in measurement application by detecting the rotational or translational displacement. To apply for flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just installed simply on the mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor, two steel leaf springs make mechanical contact and apart as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But it occurs data difference or errors by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing car near to the switch sensor installed location. In order to reduce chattering error, most system uses just software methods for example using filter and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical hysteresis characteristics.

  • PDF

A study on comparison and analysis of chlorophyll sensor with aceton extraction for chlorophyll measurement in the Nakdong River (낙동강에서 클로로필(Chlorophyll) 측정을 위한 클로로필 센서와 아세톤 추출법의 비교분석에 관한 연구)

  • Park, Joo-Hyun;Lee, Kyoung-Jin;Cho, Jae-Won;Jeon, Sook-Lye;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.325-335
    • /
    • 2015
  • Concerns about water quality in the Nakdong River have been raised because the Nakdong River will change from a lotic environment to a lentic environmental due to the installation of eight weirs to be constructed as part of the Four Major Rivers Restoration Project. The rapid urbanization and industrialization of the middle and the lower reaches of Nakdong River causes the indiscreet discharge of uncleanly living sewage and industrial wastewater. And the water quality of lower reaches of Nakdong River is getting seriously worse. Owing to the water shortage of Nakdong River and the closing of reaches because of the estuary dyke in the dry season, the velocity of a moving fluid is almost accumulated under 0.03m/sec. Then a pollutant is piled up on the bottom of the river. Polluted sediment is formed and nutrition level of water is increased more and more. The eutrophication state propagated to dark brown or green from eutrophication often comes out. Therefore in this study, we measured Chl. a of chlorophyll sensor (YSI6600V2) and aceton extraction through field observation in the Nakdong River and Samrangjin. And we evaluated the reliability of chlorophyll sensor. In correlation analysis between chlorophyll sensor and aceton extraction, it shows high relation in general. And it also shows high relation among the chlorophyll sensor and aceton extraction of the dominant diatom (Skeletonema costatum), Dinophyta (Prorocentrum minimum) in the Nakdong River estuary by laboratory analysis results.

Yeast Loading BOD Biosensor (효모균을 이용한 BOD Biosensor)

  • Kim, Mal-Nam
    • The Korean Journal of Mycology
    • /
    • v.23 no.4 s.75
    • /
    • pp.354-358
    • /
    • 1995
  • A yeast loading biochemical oxygen demand (BOD) sensor was designed and constructed to quickly measure the concentration of biologically assimilable organic substances dissolved in water as BOD values to feed back to the waste water treating processes. The sensitivity of the BOD sensor reached maximum at around pH 7.0 and $30^{\circ}C$ where yeast showed the highest assimilation activity. Biomass also affected the sensor output, and biomass of $ 0.14\;mg/cm^2$ on the dialysis membrane appeared to be the optimum cell mass level. The sensitivity of the sensor depended on the kinds of pollutants and increased considerably when the yeast was preincubated in the solution of respective pollutants before loading on the sensor.

  • PDF

An Experimental Study on the Evaluation of Mortat Unit-Water Content by Powder Ratio Using Frequency Domain Reflectometry Sensor (고주파수분센서를 활용한 분체 비율별 모르타르 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Wi, Kwang-Woo;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.109-110
    • /
    • 2022
  • Currently, interest in the quality of concrete is increasing. Among the important factors for evaluating the quality of concrete, interest in unit-water content is also increasing. Currently, the air-meter method, the microwave oven drying method, the capacitance method, and the microwave penetration method are used to measure the unit-water content of concrete.. Among the above methods, except for the microwave method, the measurement method is complicated, portability is reduced, and economic efficiency is reduced. This research aims to measure a unit-water content by using a Frequency Domain Reflectometry(FDR) sensor that is economical, simple to measure, and portable among microwave methods. In addition, it is an experimental study to determine the accuracy of unit-water content using a single input residual model during deep learning to solve the limitations of the FDR sensor.

  • PDF

A Study on the Evaluation of Concrete Unit-Water Content of FDR Sensor Using Deep Learning and Machine Learning (딥러닝과 머신러닝을 이용한 FDR 센서의 콘크리트 단위수량 평가에 관한 연구)

  • Lee, Seung-Yeop;Youn, Ji-Won;Wi, Gwang-Woo;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.29-30
    • /
    • 2022
  • The unit-water content has a very significant effect on the durability of the construction structure and the quality of concrete. Although there are various methods for measuring the unit-water content, there are problems of time required for measurement, precision, and reproducibility. Recently, there is an FDR sensor capable of measuring moisture content in real time through an apparent dielectric constant change of electromagnetic waves. In addition, various artificial intelligence techniques that can non-linearly supplement the accuracy of FDR sensors are being studied. In this study, the accuracy of unit-water content measurement was compared and evaluated using machine learning and deep learning techniques after normalizing the data secured in concrete using frequency domain reflectometry (FDR) sensors used to measure soil moisture at home and abroad. The result of comparing the accuracy of machine learning and deep learning is judged to be excellent in the accuracy of deep learning, which can well express the nonlinear relationship between FDR sensor data and concrete unit-water content.

  • PDF

Disposable Nitrate-Selective Optical Sensor Based on Fluorescent Dye

  • Kim, Gi-Young;Sudduth, Kenneth A.;Grant, Sheila A.;Kitchen, Newell R.
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.209-213
    • /
    • 2012
  • Purpose: This study was performed to develop a simple, disposable thin-film optical nitrate sensor. Methods: The sensor was fabricated by applying a nitrate-selective polymer membrane on the surface of a thin polyester film. The membrane was composed of polyvinylchloride (PVC), plasticizer, fluorescent dye, and nitrate-selective ionophore. Fluorescence intensity of the sensor increased on contact with a nitrate solution. The fluorescence response of the optical nitrate sensor was measured with a commercial fluorospectrometer. Results: The optical sensor exhibited linear response over four concentration decades. Conclusions: Nitrate ion concentrations in plant nutrient solutions can be determined by direct optical measurements without any conditioning before measurements.