• Title/Summary/Keyword: Water Quality Standards

Search Result 475, Processing Time 0.026 seconds

Advanced Treatment of Liquid Fertilizer from Livestock Night Soil Treatment Facility by Membrane Separation Processes (분리막 공정을 이용한 축산분뇨 처리장 액비의 고도처리)

  • Kim, Joo-Hye;Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.142-150
    • /
    • 2014
  • This paper is to develop the process suitable for the advanced treatment of liquid fertilizer from the livestock night soil treatment facility (biogas plant). Nanofiltration (NF) and reverse osmosis (RO) process was used, respectively, for the advanced treatment of liquid fertilizer. And membrane bioreactor (MBR) with and without biomedia were tested, respectively, for the pretreatment. It was found that almost T-N of the liquid fertilizer was composed of ammoniacal nitrogen. Transmembrane pressure of MBR with biomedia increased slowly during the operation time, while that of MBR without biomedia increased rapidly at the initial time. But there was no difference observed in the removal efficiencies of COD, T-N, and T-P irrespective of the dosage of biomedia. When the liquid fertilizer was pretreated by MBR with biomedia, the removal efficiencies of COD, T-N, and T-P were 99.8, 86.5%, and 99.8% by NF, and 99.9, 86.8%, and 99.8% by RO, respectively. Compared with the effluent quality standards of the livestock night soil treatment facility, the water quality treated by MBR and NF/RO process met the standard for COD and T-P, but exceeded the permitted standard for T-N. In order to meet the effluent quality standard for T-N, it is necessary to change the MBR operation cycle or to add the secondary treatment by NF/RO.

Evaluation on Four Volatile Organic Compounds (VOCs) Contents in the Groundwater and Their Human Risk Level

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-Hyun;Lee, Gyeong-Mi;Kim, Ki-In;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.4
    • /
    • pp.235-250
    • /
    • 2017
  • In this study, we monitored 4 volatile organic compounds (VOCs) such as chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane in groundwater samples to determine the detection frequency and their concentrations and evaluated the health risk level considering ingestion, inhalation, and skin contact. 75 groundwater wells were selected. 24 wells were from monitoring background groundwater quality level and 51 wells were from monitoring groundwater quality level in industrial or contamination source area. In the results, the detection frequency for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane was 42.3%, 8.1%, 6.0%, and 3.4%, respectively. The average concentrations of VOCs were high in the order of chloroform ($1.7{\mu}g\;L^{-1}$), dichloromethane ($0.08{\mu}g\;L^{-1}$), tetrachloromethane ($0.05{\mu}g\;L^{-1}$), and 1,2-dichloroethane ($0.05{\mu}g\;L^{-1}$). Chloroform had the highest detection frequency and average detection concentration. In the contaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, 1,2-dchloroethane, and tetrachloromethane. The average concentrations for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane were $2.23{\mu}g\;L^{-1}$, $0.08{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.06{\mu}g\;L^{-1}$, respectively. All the 4 compounds were detected at industrial complex and storage tank area. The maximum concentration of chloroform, dichloromethane, and 1,2-dichloroethane was detected at industrial complex area. Especially, the maximum concentration of chloroform and dichloromethane was detected at a chemical factory area. In the uncontaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, and 1,2-dchloroethane and tetrachloromethane was not detected. The average concentrations for chloroform, dichloromethane, and 1,2-dichloroethane were $0.57{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.03{\mu}g\;L^{-1}$, respectively. Although chloroform in the uncontaminated groundwater was detected the most, the concentration of chloroform was not exceeding water quality standards. By land use, the maximum detection frequency of 1,2-dichloroethane was found near a traffic area. For human risk assessment, the cancer risk for the 4 VOCs was $10^{-6}{\sim}10^{-9}$, while the non-cancer risk (HQ value) for the 4 VOCs is $10^{-2}{\sim}10^{-3}$.

Characteristics of the Newly Developed Rain Shelter for Grapevine and Growth of 'Campbell Early' (신개발 포도 비가림 시설의 특성과 '캠벌얼리'의 생육)

  • Lee, Yun Sang;Kim, Seung Deok;Lee, Seok Ho;Hong, Seong Taek;Lee, Jae Wung;Hong, Eui Yon;Kim, Dae Il
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.252-257
    • /
    • 2015
  • Fruit cracking and vine leaf spot of grapes tend to occur when the plants were directly exposed to rain under outdoor culture. Rain shelter facility can be an alternative method to prevent the cracking and disease of grape, but it also has some limitations in practical usages. We designed rain shelter facility which can completely shut out the rain and ventilate naturally, and it was upgraded to meet the standards of disaster prevention against snow and wind load. The newly developed rain shelter has two-story roof structure, and the $2^{nd}$ floor roof was equipped over $1^{st}$ floor roof at a distance of 40cm. For natural ventilation and water proof, the upper roof protruded about 50cm from the ridge of a $1^{st}$ floor roof. The various tests were carried to examine such as grape quality, brown spot and fruit cracking of Campbell Early under the conventional and the newly developed rain shelter facility which was built about $100{\ss}{\check{S}}$. In comparison of temperature between the conventional and the newly developed rain shelter facility when outside temperature was more than $34^{\circ}C$, the inside temperature was recorded as $40.7^{\circ}C$ and $37.4^{\circ}C$, respectively. There was no significant difference between the two facilities when outside was below $32^{\circ}C$ The quality such as soluble solids and marketable fruit was increased, and fruit cracking of grapes and vine leaf spot also drastically diminished in the newly developed rain shelter.

Evaluation of Organic Sediments Qualities for the Urban Streams in the Busan City (부산시 하천퇴적물의 유기 오염도 평가)

  • Lee, Jun-Ki;Kim, Seog-Ku;Song, Jae-Hong;Lee, Tae-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.975-982
    • /
    • 2009
  • The purpose of this study is to offer informations about the current conditions and basic data of stream sediments in Busan city. So we first select 14 urban streams and collect sediment samples. Then, COD, proximate analysis, volatile solid, organic carbon content and elemental analysis were conducted to determine characteristics of the sediments. Results show that COD, volatile solid, Organic carbon content, T-N of sediment are determined in the range of 1.20~75.07 mg/g, 0.19~11.54%, 0.23~34.21% and 0.76~3.46%, respectively. Analysis data of sediments were compared with USEPA sediment quality standards and ontario sediment quality guidelines. As a result, when compared with COD, volatile solid and organic carbon content values, Bosucheon and Gudeokcheon are relatively heavily contaminated than the remainder sampling sites. But when compared with T-N values, all of sites were evaluated as seriously contaminated. Finally, for the determination of the correlations between sediment COD and moisture contents, ash contents, volatile solid, total organic carbon, total nitrogen and total carbon, linear model was fitted to the data using a least-squares algorithm. As a result, Linear model was well fitted to each data with good values of the correlation coefficient (r=0.9664~0.8501).

Case Study of Cost Effect Analysis for Toxic Compounds to Developing Effluent Limitation Standards : Focus on 1,4-Dichlorobenzene (수질유해물질 배출허용기준 설정에 따른 배출시설 비용영향 분석사례 연구: 1,4-Dichlorobenzene을 중심으로)

  • Kim, Kyeongjin;Kim, Wongi;Heo, Jin;Kim, Kwangin;Kim, Jaehoon;Kim, Sanghun;Yeom, Icktae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.4
    • /
    • pp.557-565
    • /
    • 2010
  • Recently, regulations on toxic compounds in aquatic environment have been strengthened in korea due to the increasing public awareness of the water quality. Typically, these regulations include introduction of emerging toxic compounds and stricter effluent limitations for the already regulated compounds. However, too strict regulations may cause excessive burden on the industry. Therefore it is also important to assess the economic impacts when the new effluent limitation guidelines are introduced. The estimation of the additional cost for the wastewater dischargers to meet the new guidelines are based on the selected treatment technology to handle the hazardous substances and the regulatory levels for effluent limitations. To explore the procedures for cost estimation in enforcing new effluent limitations, a case study was performed specially for 1,4-dichlorobenzene. The pollutants of concern are surveyed for different industrial categories and various treatment technologies. For a given pollutant, the general performances of the treatment technologies are surveyed and a representative technology is selected. For a given technology, the capital cost and annual Operation and Maintenance (O&M) cost was calculated. The calculation of baseline costs to operate ordinary treatment technologies is also important. The ratio between the cost for introducing new treatment process and the baseline cost required for conventional technology was used to evaluate the economic impact on the industry. For 1,4-dichlorobenzene, steam stripping and activated carbon processes were selected as the specific treatment technologies. The cost effects to the regulation of the compound were found to be 6.4% and 14.5% increase in capital cost and O&M cost, respectively, at the flow rate over $2,000m^3/d$ for the categories of synthetic resin and other plastics manufacturing industry. For the case of petrochemical basic compounds manufacturing industry, the cost increases were 5.8% and 12.4%, respectively. It was suggested that cost effect analysis to evaluate the economic impacts of new effluent limitations on the industry is crucial to establish more balanced and reasonable effluent limitations to manage the industrial wastewater containing emerging toxic compounds in the wastewater.

A Study on the Effectiveness Verification of Hydrological Cycle of Pervious Pavement using LID Simulator (LID 효율성 검증기기를 이용한 투수성 블록의 수문순환 효율성 검증에 관한 연구)

  • Kim, Mi Eun;Jang, Young Su;Nam, Chil Ho;Shin, Hyun Suk
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.321-330
    • /
    • 2015
  • In recent, the impacts of urbanization on hydrology and water quality can be minimized with the use of Low Impact Development (LID) practices in urban areas. But, there are no ways to verify or to show the quantitative effectiveness with LID practices. This study designed and developed to perform experiments in natural or artificial representation of hydrological cycle, which is called rainfall-runoff simulator to be able to quantify factors in hydrological system. This simulator was applied to a pervious pavement block. The study conducted analysis of effectiveness for a pervious pavement block by comparing the results with a general pavement block. The result from the pervious pavement block showed remarkably reduction effect on surface runoff with increase of rainfall intensity and more duration time. Also, the simulator was possible to control no surface runoff by a rainfall intensity at 50 mm/hr for an hour. The research indicated possibility and effectiveness for LID practices. This might be widely available to apply to LID practices verification. Therefore, the study is possible to make use of practical standards on fundamental studies.

A Study on the Quality Properties of Porous concrete for Pavement Using Silica Fume and Steel Fiber (실리카퓸 및 강섬유를 이용한 포장용 포러스콘크리트의 품질특성에 관한 연구)

  • Park, Seung-Bum;Lee, Jun;Seo, Dae-Seuk;Yoon, Eui-Sik
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.31-42
    • /
    • 2005
  • This study evaluates the physical mechanical properties, durability and sound absorbtion of porous concrete for pavement according to content of silica fume and steel fiber to elicit the presentation of data and the way to enhance its function for the practical field application of porous concrete as a material of pavement. The results of the test indicate that in every condition, the void ratio and the coefficient of water permeability of porous concrete for pavement satisfy both the domestic standards and proposition values. Among the properties of strength, the compressive strength satisfies the standards in the specification of Korea National Housing Corporation as for every factor of mixture but in the case of the flexural strength, more than 0.6vol.% of steel fiber satisfied the Japan Concrete Institute proposition values. The mixture of silica fume and steel fiber presents the excellent intensity, though. The case when silica fume and steel fiber are used simultaneously presents the strongest durability because the durability shows the similar tendency to the dynamic characteristics. The case when 10wt.% of silica fume and 0.6vol.% of steel fiber are used at the same time shows that the loss rate of mass by Cantabro test became 27% better and freeze-thaw resistance became 60% better. As for the characteristics of sound absorption of porous concrete for pavement, Noise Reduction Coefficient is 0.48 to prove that it possesses almost 50% sound absorption.

  • PDF

Relationship between Soil Management Methods and Soil Chemical Properties in Protected Cultivation

  • Kang, Yun-Im;Lee, In-Bog;Par), Jin-Myeon;Kang, Yong-Gu;Kim, Seung-Heui;Ko, Hyeon-Seok;Kwon, Joon-Kook
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • Various cultural practices have been promoted as management options for enhancing soil quality and health. The use of soil management methods can cause changes in fertility by affecting soil chemical properties. This study aimed to evaluate interactions between soil chemical properties and soil management methods in protected cultivation, and to classify soil management methods that similarly affect soil chemical properties. Water-logging and irrigation reduced soil pH and available $P_2O_5$ content. Application of animal manures has a positive effect on levels of organic matter, Av.$P_2O_5$, K, Zn, and Cu. The electrical conductivites tened to be low in the application of organic amendments, including rice and wood residues. Deeper plowing caused a reduction in Ca content. Practicing soil nutrient-considering fertilization and fertigation did not exert an influence on nutrient element contents. In a cluster analysis of the soil management methods according to major nutrients, low similarities were found with deeper plowing and crop rotation with rice in comparison with other practices. In a cluster analysis by minor nutrient characteristics, crop rotation and application of animal manures and rice residues were linked at a high Ward's distance, while other practices were found to be relatively low distinct. Each soil management method has a similar or different effect on soil chemical properties. These results suggest the necessity of establishing limits and standards according to the effects of soil management methods on soil chemical properties for economic soil practices.

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

Application of Sand Mat Substitutel using Steel Slag (제강슬래그를 이용한 샌드매트 대체재료의 적용성 연구)

  • Park, Jong-Beom;Lee, Byung-Chan;Ju, Jae-Woo;Na, Hyun-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • Steel slag has the nature to hydrate and expand when in contact with non-reacting CaO and water, and thus can be used only in limited scope for landfill disposal as well as for recycling as civil construction aggregates. In order to use such steel slags more efficiently, the applicability of steel slag as sand mat alternative material was reviewed. In general, sand mat is used in soft ground surface reinforcement method and horizontal drain method, and is installed simultaneously with soft ground vertical drain method. Therefore in this study steel slag designing method and application standard etc were examined to recycle steel slag as sand mat alternative material, and laboratory soil test and model test were done. Test results indicated that the designing method and application standard meet various environment and quality standards, meaning that steel slag can be utilized as sand mat alternative material, and analysis of slag mat bearing capacity also indicated that use of steel slag produces double or more bearing capacity compared with existing sand mat.