• 제목/요약/키워드: Water Quality Standards

검색결과 475건 처리시간 0.029초

Object oriented linking of GIS to assess ground water quality in Dharmapuri district, India

  • Devi, K.K.Manjula;M, Prashanthi Devi.;Kumar, D. Nandha;Balasubramanian, S
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1439-1441
    • /
    • 2003
  • The World Health Organisation has identified ‘Fluorosis’as a serious bone disease caused by groundwater. Though the fluoride content in groundwater is a natural phenomenon, when the permissible limit of fluoride is exceeded the consequences may be fatal. This study is identified areas of high fluoride content in the Dharmapuri district of India, which is one of the major districts severely affected by fluorosis (WHO). The approach to this problem is by using GIS as a tool to locate areas of high risk. Ground Water samples collected from 35 randomly located wells (open / bore wells) in the district were analysed for fluoride content. The results were compared with the standards of WHO (World Health Organisation ), ICMR (Indian Council of Medical Research ), BIS (Bureau of Indian Standard) and PHE (Public Health Engineering) and interpolated using IDW and spline methods using Arcview GIS 3.2 a. A computer based automated information system was developed in Arcview Avenue 3.2a, so as to enable the user to visit the risk areas at his desktop and to remediate measures as and when required.

  • PDF

비점오염원 관리지역의 선정 기법에 관한 연구 (A Study for the Selection Method of Control Area of Nonpoint Pollution Source)

  • 박상현;정우혁;이상진;임봉수
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

지하수중 음이온, 양이온, 및 금속의 함량 (Groundwater Contamination by Cation, Anion and Pesticides)

  • 김형석;정세영;최중명
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

GAP 농산물의 수확 후 처리에 사용되는 지하수의 위해성평가 (Risk Assessment of Groundwater Used for Washing GAP-certified Agricultural Crops after Harvest)

  • 김황용;백민경;김아름누리;이동규;정미혜;김원일;오진아;김세리;홍수명
    • 한국식품위생안전성학회지
    • /
    • 제34권6호
    • /
    • pp.551-556
    • /
    • 2019
  • 세척수에 포함된 무기물질의 함량이 먹는 물의 수질기준을 초과하여, 참외 GAP 인증을 받지 못하는 사례가 최근 들어 종종 발생하고 있다. 이에 농업현장에서는 껍질을 제거하여 먹는 참외의 소비특성을 감안하여 세척수 수질기준의 일부를 완화해 줄 것을 요청하고 있다. 이에, 본 연구에서는 성주 지역에서 2017-2019년 GAP 인증 참외의 세척에 이용되는 지하수 142건의 수질자료를 근거로 무기물질 4종(불소, 비소, 철, 망간)의 인체 위해성을 평가하였다. 연구 결과, 성주 지역 GAP 참외의 세척에 사용되는 지하수를 음용수 수준으로 섭취하는 우리나라 국민의 4종 무기물질에 대한 HQ는 모두 평균 0.10 이하로 안전한 수준이었다. 특히, 심미적 영향물질인 철, 망간의 경우 성주 지역 지하수를 음용수 수준으로 섭취하는 경우 HQ가 평균 0.00. 과다노출군의 경우 0.01나타났는데, 일반 참외를 섭취하는 국민의 HQ(평균 0.01, 과다노출군 0.03)보다 낮은 수준이었다. 따라서, 성주 지역 지하수를 GAP 농산물의 세척에 활용하더라도 철, 망간을 포함한 4종 무기물질이 인체에 미치는 영향은 미미할 것으로 생각된다.

낙동강 중·하류 지역의 수변 특성에 관한 연구 (Riparian Area Characteristics of the Middle and Lower Reaches of the Nakdong River, Korea)

  • 강대석;성기준;여운상;정용현;이석모
    • 환경영향평가
    • /
    • 제17권3호
    • /
    • pp.189-200
    • /
    • 2008
  • As a transition zone between terrestrial and aquatic ecosystems, riparian areas of rivers and streams play significant roles in production and decomposition for river and stream systems. Understanding of the physical and ecological characteristics of riparian areas are, therefore, important for the management of river and stream systems. It is especially important to understand the characteristics of riparian areas for the Nakdong River in Korea which has a large watershed area and diverse land uses. This study aimed at collecting field data, according to stream types, which are essential for the management of riparian areas of the middle and lower reaches of the Nakdong River, Korea. Most riparian areas surveyed in this study had roads within 100 meters from river edges. Distances from water edge to banks were less than 1m for most riparian areas neighboring agricultural lands, indicating that those areas might be very vulnerable to pollutant inputs from non-point sources. Water quality data indicated that soil erosion in the riparian areas could be a major source of phosphorus input to the Nakdong River and land use patters might have a significant influence on nitrogen concentration in the river. Heavy metal concentrations in soils of the riparian areas of the river were below soil quality standards, except arsenic and chromium. Vegetation surveys showed that therophytes were the most frequently occurred riparian plants in the Nakdong River. Number of aquatic plant species increased downstream, with the most diverse aquatic plants observed in wetlands and irrigation canals of the West Nakdong River. Occurrence rate of naturalized plants and urbanization index were high in the survey sites adjacent to urban and agricultural areas.

XAD 수지에 의한 친수성 및 소수성 수용성 유기탄소의 특성조사 (Study on Characterization of Hydrophilic and Hydrophobic Fractions of Water-soluble Organic Carbon with a XAD Resin)

  • 정재욱;김자현;박승식;문광주;이석조
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.337-346
    • /
    • 2011
  • 24-hr integrated measurements of water-soluble organic carbon (WSOC) in PM2.5 were made between May 5 and September 25, 2010, on a six-day interval basis, at the Metropolitan Area Air Pollution Monitoring Supersite. A macro-porous XAD7HP resin was used to separate hydrophilic and hydrophobic WSOC. Compounds that penetrate the XAD7HP column are referred to hydrophilic WSOC, while those retained by the column are defined as hydrophobic WSOC. Laboratory calibrations using organic standards suggest that hydrophilic WSOC includes lowmolecular aliphatic dicarboxylic acids and carbonyls with less than 4 or 5 carbons, amines, and saccharides. While the hydrophobic WSOC is composed of compounds of aliphatic dicarboxylic acids with carbon numbers larger than 4~5, phenols, aromatic acids, cyclic acid, and humic-like Suwannee River fulvic acid. Over the entire study period, total WSOC accounted for on average 48% of OC, ranging from 32 to 65%, and hydrophilic WSOC accounted for on average 30.5% (9.3~66.7%) of the total WSOC. Based on the previous results, our measurement result suggests that significant amounts of hydrophobic WSOC during the study period were probably from primary combustion sources. However, on June 9 when 1-hr highest ozone concentration of 130 ppb was observed, WSOC to OC was 0.61, driven by increases in the hydrophilic WSOC. This result also suggests that processes, such as secondary organic aerosol formation, produce significant levels of hydrophilic WSOC compounds that add substantially to the fine particle fraction of the organic aerosol.

Efficient aerobic denitrification in the treatment of leather industry wastewater containing high nitrogen concentration

  • Kang, Kyeong Hwan;Lee, Geon;Kim, Joong Kyun
    • Environmental Engineering Research
    • /
    • 제20권1호
    • /
    • pp.79-87
    • /
    • 2015
  • To treat leather industry wastewater (LIW) containing high nitrogen concentration, eight aerobic denitrifiers were isolated from sludge existing in an LIW-treatment aeration tank. Among them, one strain named as KH8 had showed the great ability in denitrification under an aerobic condition, and it was identified as Pseudomonas aeruginosa R12. The aerobic denitrification ability of the strain KH8 was almost comparable to its anaerobic denitrification ability. In lab-scale aerobic denitrifications performed in 1-L five-neck flasks for 48 hr, denitrification efficiency was found to be much improved as the strain KH8 held a great majority in the seeded cells. From the nitrogen balance at the cell-combination ratio of 10:1 (the strain KH8 to the other seven isolates) within the seeded cells, the percentage of nitrogen loss during the aerobic denitrification process was estimated to be 58.4, which was presumed to be converted to $N_2$ gas. When these seeded cells with lactose were applied to plant-scale aeration tank for 56 day to treat high-strength nitrogen in LIW, the removal efficiencies of $COD_{Cr}$ and TN were achieved to be 97.0% and 89.8%, respectively. Under this treatment, the final water quality of the effluent leaving the treatment plant was good enough to meet the water-quality standards. Consequently, the isolated aerobic denitrifiers could be suitable for the additional requirement of nitrogen removal in a limited aeration-tank capacity. To the best of our knowledge, this is the first report of aerobic denitrifiers applied to plant-scale LIW treatment.

미세먼지 오염도가 높은 지역의 성인남성의 식품 및 영양소 섭취 실태 분석: 국민건강영양조사 2013-2017 자료 활용 (Analysis of Nutrient Intake Status of Adult Men in Areas with High Levels of Fine Dust Pollution: Korea National Health and Nutrition Examination Survey (2013-2017))

  • 유다솜;강남이;장세은;오윤신
    • 한국식생활문화학회지
    • /
    • 제36권5호
    • /
    • pp.464-473
    • /
    • 2021
  • Although fine dust pollution in Korea is increasing, there is no information regarding nutritional standards for fine dust-related disease patients. This study analyzed the food and nutrient intake status in adult men with disease associated with fine dust in the area with the increased level of fine dust pollution using the sixth and seventh Korea National Health and Nutrition Examination Survey (2013-2017). The daily intakes, and average nutrient adequacy ratio (NAR) and mean adequacy ratio (MAR) values of energy were significantly increased in the control group compared with patient groups. Compared with the control group, protein, fat and cholesterol intakes were significantly increased in the patient groups. Daily intakes of cereals and grain products in the control group were increased, whereas seasoning intake was decreased in the control group compared with patient groups. The patient groups had low daily water and vitamin B1 intakes, and the niacin intake of patient groups was significantly lower than that of the control group. Nutrition density and nutritional quality of vitamin C were significantly reduced in patient groups. This study can be used as basic data for nutrition education that emphasizes sufficient calorie, water and antioxidant vitamin intakes for patients related to fine dust pollution.

수질 배출기준 및 세제 안전기준에 적합한 산업용 알칼리 세탁세제의 세척성과 세탁조건 연구 (A Study on the Washability and Washing Conditions of the Industrial Alkaline Laundry Detergent Suitable for Water Discharge Standards and Detergent Regulations)

  • 송현주;송선혜
    • 한국염색가공학회지
    • /
    • 제33권4호
    • /
    • pp.250-257
    • /
    • 2021
  • Laundry industry has traditionally been considered an industry that generates large amounts of wastewater and Volatile Organic Compounds(VOCs). This is still the case until now. Household laundry detergents are produced and distributed within the safety regulations on the amount of harmful substances detected. While industrial laundry detergents are often distributed without safety regulations, and even laundry workers manufacture and use them on their own. This contaminates water and air and also threatens the safety of workers. This study is a basic study for distributing eco-friendly detergents(EFD-A) developed through previous studies to the laundry industry. Safety, washability and wastewater quality of EFD-A are evaluated. Three existing commercial detergents(PD1, PD2, LD4) are also evaluated to compare with EFD-A. The safety of detergents is confirmed by the content of optical brightener, VOCs, and arsenic. Washability is evaluated by the difference in reflectance of washed and unwashed artificial soiled fabrics according to detergent concentration, washing temperature, and washing time. TOC is used as the index of assessing the wastewater quality. The results are as follows; EFD-A doesn't contain the optical brighteners, VOCs, and arsenic. The optimal washing conditions for EFD-A are 3 g/L concentration, 40 ℃ washing temperature, and 30 min washing time. The soil removal efficiency is about 71 %, which was similar to or somewhat superior to that of PD1, PD2, and LD4. TOC is 63.5 %, which is about 15 % lower than the discharge limit. Through this study, the developed detergent EFD-A can be used as a safe and eco-friendly detergent for the human body and the environment.