• Title/Summary/Keyword: Water Purifier

Search Result 89, Processing Time 0.029 seconds

A study on characteristics of filters for domestic household water purifier (국내 가정용 정수기 필터의 특성 분석에 관한 연구)

  • Cho, Jae-Ik;Kim, Gil-Tae;Ahn, Young-Chull
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.541-547
    • /
    • 2013
  • It is important to establish water treatment technologies for drinking water because Korea belongs to water-stressed country. Leachate from recent incident of foot-and-mouth disease has become an opportunity to be aware of the need to manage water quality. Water purifiers are adopted to four or five steps of filtration process. Each steps are composed of a sediment filter, a pre-carbon filter, an UF or a RO membrane filter and a post-carbon filter. And additionally a ceramic filter can be used as a final stage. In this study, operational conditions in each steps are examined and characteristics of each filters are investigated. SEM analysis is used for filter surface and shape investigation using 6 commercial samples. Pore sizes of the sediment filter, the UF membrane filter, and the RO membrane filter are 30~47 ${\mu}m$, 0.005~0.5 ${\mu}m$, and 0.025~0.25 ${\mu}m$, respectively. Specific surface areas of activated carbons are ranged from 622 to 1,308 $m^2/g$.

Performance Evaluation of Hydrogen Separation and Generator for Hydrogen Water (수소수를 위한 수소분리 및 생성기 성능 평가)

  • Kim, Gui-Jung;Han, Jung-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.281-286
    • /
    • 2016
  • In this paper, we optimized the structure of hydrogen water generator and assessed by developing a generator with dissolved hydrogen amount(1,000~1,200 ppb) of world-class level. Evaluation is divided into four types, such as dissolved hydrogen amount, pH, maximum pressure, redox potential, and it was evaluated for each of the targets. It was performed through the experiment of four in all five times and all of them show superiority results appearing in the target range. In addition, the assessment got 25/30 functionality, 17/20 maintainability, 26/30 usability, and 19/20 efficiency. In particular, we proved the validity of this study in high efficiency. We developed this hydrogen water generator system as possible to be substitution of water purifier.

Maximum Value Calculation of High Dose Radioiodine Therapy Room (고용량 방사성옥소 치료 병실의 최대치 산출)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.

  • PDF

Comparison of Bacterial Regrowth on Plant- and Coal-based Granular Activated Carbon (식물계활성탄과 석탄계활성탄에서의 세균재생장 비교)

  • 이동근;박성주;하배진;하종명;이상현;이재화
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.104-109
    • /
    • 2004
  • Activated carbon has been used in water treatment, because they strongly adsorb organic material including contaminant. Water purifier usually use activated carbon, and bacterial regrowth on that could induce many problems. Model columns, packed with coal- and plant-based granular activated carbon (GAC), were operated with rechlorinated tap water to compare the degree of bacterial regrowth on different GACs. GAC columns decreased the concentration of total organic carbon and chlorine, while they are not good for the decrease of ions. Breakthrough of bacteria were occurred after eight days of operation, and reached 1.1 ${\times}$ 10$^3$ CFU/mL on coal based GAC and 6.2 ${\times}$ 10$^2$ CFU/mL on coconut based one. Bacterial activities on GAC were between 15.35 ∼ 29.06 $\mu\textrm{g}$ INT-formazan/g-GAC/h. Bacterial concentration and activities were higher in coal based GAC than coconut based one. Bacterial regrowth on GAC was clarified and regrowth effect of coal-based GAC was higher than that of coconut-based one.

Optimization of Coal Ash Water Treatment Conditions to Suppress Concrete Pop-out Based on Coal Ash Containing Expansion Components (팽창성분이 혼입된 석탄재 기반 콘크리트의 팝아웃 발생 억제를 위한 석탄재 수처리 조건 최적화)

  • Jae-Jin Hong;Joo-Han Kang;Mi-Na Kim;Woo-Seong Choi;Myung-Jun Oh;Seong-Yun Kim
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.226-231
    • /
    • 2024
  • Coal ash has been used as a sand replacement in the construction industry. Due to the use of bituminous coal as a result of anthracite depletion, and quicklime as an air purifier in the desulfurization process, pop-out defects have recently occurred in concrete using coal ash, severely limiting the recycling of coal ash into concrete. In this study, the components that cause the pop-out problem of the coal ash filled concrete were identified and a pretreatment method to fully expand the expansive components in advance was proposed as a solution to this problem. By treating water twice for 10 min, allowing the CaO mixed in the coal ash to fully expand, the problems of pop-out and reduced compressive strength of the concrete were overcome. The cost and time efficient water treatment method proposed in this study is expected to promote the recycling of coal ash into concrete.

Manufacturing and Antibacterial Characteristics of Functional Non-woven Fabrics Including Nano-silver Particles (은 나노 입자를 함유한 기능성 부직포의 제조와 항균특성)

  • Ro, Duck-Kil;Hong, Young-Ki;Park, Eun-Hee
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.18-25
    • /
    • 2008
  • The functional non-woven fabrics have been applied in various industry fields, such as clothing, hygiene, environment, medical and so forth. The functional non-woven fabrics were manufactured by meltblown and finishing processes. These functional non-woven fabrics were based on 5wt% masterbatch using 2,000ppm nano-silver resin composite. Silver is one of the most universal antimicrobial substances. Nano-technology enables us to expand the surface area of silver particles markedly. Silver nano particles were successfully produced less than 50nm in size. The functional non-woven fabrics including nano-silver particles showed excellent antibacterial activities against Staphylococcus aureus (ATCC 6538) and Klebsieila pneumoniae (ATCC 4352). From the results, functional non-woven fabrics including silver nano particels probably will be available as a good and safe antibiotic alternative, such as mask medium filter, water purifier filter, hygiene wet tissues, marine products pad and so forth.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

Identification and Distribution of the Pathogenic Microorganisms Isolated from Edible Ice in North Area of Daegu, Korea (대구시 북구지역의 식용얼음에서 세균 분포 및 동정)

  • Kim, Su-Jung
    • Korean Journal of Microbiology
    • /
    • v.45 no.1
    • /
    • pp.86-90
    • /
    • 2009
  • The definition of edible ice is frozen water for the use of food manufacturing, processing, or cooking, as well as for the direct eating. It has been reported that in the process of ice manufacturing and its selling, edible ice is contaminated with some microorganisms, which causes food poisoning and gastroenteritis. It was shown that besides in the edible ice, germ growth caused by various reasons occurred in the mineral water, tap water, water filtering system, and water purifier. With public awareness, in order to examine the sanitary conditions of edible ice in the Northern area of Daegu metropolitan city, 15 places were randomly selected. As a result, 14 places were found to be contaminated with microorganisms. After incubating on the Brain Heart Infusion (BHI) agar plate, 80% of Gram-negative bacilli, 17% of Gram-positive cocci, and 3% of Gram-negative cocci were cultured. Enterobacter cloacae, Chryseomonas luteola, Pantoea spp., Klebsiella pneumoniae, Acinetobacter baumannii, Acinetobacter calcoaceticus or Providencia rettgeri were detected. Gram-positive cocci cultured in BHI agar plate from 5 specimens were identified as Staphylococcus aureus or Staphylococcus xylosus, which is well known bacteria causing strong food poisoning. This present paper raises questions on the importance and awareness of sanitary conditions of edible ice and the identification of pathogenic microorganisms living in the edible ice in relation to their distribution. The examination of sanitary conditions of edible ice in other areas in Daegu seems to be also needed to find out if there are similar cases.

Synthesis of Ceramic Support for Immobilization of Microorganisms Using Fly Ash (석탄회를 이용한 미생물 고정화 세라믹 담체 제조)

  • Shin, Dae-Yong;Han, Sang-Mok;Choi, Shin-Geon
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.857-862
    • /
    • 2002
  • Porous ceramic supports with immobilized microorganisms for the water purifier were synthesized by firing green compacts of mixed powder comprising of fly ash, bentonite and an additive of yeast powder at 800∼1,000$^{\circ}C$ for 1h and the pore and mechanical properties of specimens were investigated. The compressive strength was increased in FB (Fly Ash + Bentonite) specimens while pore properties was decreased with increasing the bentonite content and sintering temperature. The compressive strength, bulk density, apparent density, porosity, mean pore size, pore volume and specific surface area of FB specimens at 800∼1,000$^{\circ}C$ were 89.6∼128.9 kgf/$cm^2$, 1.25∼1.43, 1.61∼1.78, 27.2∼62.2%, 7.9∼25.6 ${\mu}m$, 8.9∼$22.2{\times}10^{-5}\;cm^3/g$ and 35.2∼134.3 $m^2/g$, respectively. The pore properties of FBY (FB+yeast powder) specimens were superior to that of FB specimens, however compressive strength was decreased with increasing yeast powder content. The overall properties of 9F1B1Y (9F1B+10% of yeast powder) specimens at 900$^{\circ}C$ for 1 h were 98.7 kgf/$cm^2$, 1.20, 1.67, 68.1%, 48.9 ${\mu}m$, $29.5{\times}10^{-5}\;cm^3/g$ and 152.2 $m^2/g$, respectively. In this study, it was revealed that 9F1B1Y specimen demonstrated better S. saprophyticus adherence properties n their surface pores. Consequently, the microorganisms immobilized on porous ceramic supports showed better water purifying performance with many pores and adequate strength.

Survey on the Current Status of Ecocentric Environmental Education in Korean Alternative Schools (대안학교의 생태중심주의 환경교육 실태 조사)

  • Kim, Youngjoo;Cha, Jeongho;Cheong, Cheol;Lee, Jung Ho
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.320-326
    • /
    • 2010
  • This study explored the current status of ecocentric environmental education in alternative schools. We analyzed the aims, curriculum, environmental activities of 42 alternative schools in Korea from their homepages and guidebooks. For more information, additional interviews with teachers were also conducted. As a resuts, the ratio of schools aiming ecologism were relatively low, however, 36 (85.7%) of 42 alternative schools included ecologism in their educational goals directly or indirectly. 39 schools included an environmental education in their curriculum, and 3 environmental class was opened in a week on the average. The most frequently used environmental activity in alternative schools was "recycling of solid wastes", and then "reducing use of disposable products", and "using environment-friendly, and recycled products" were followed. "Using water-purifier tank" and "using alternative energy" were also practiced. Educational implications of results were discussed.

  • PDF