• 제목/요약/키워드: Water Pressure

검색결과 6,434건 처리시간 0.031초

감압법을 이용한 메탄하이드레이트 생산에 대한 수치적 연구 (Numerical Study on the Production of Methane Hydrate by Depressurization Method)

  • 김진홍;천원기;김남진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.519-523
    • /
    • 2007
  • Gas(or methane) hydrates are solid solutions when water molecules are linked through hydrogen bonding and create host lattice cavities that can enclose a large variety of guest gas molecules. The natural gas hydrate crystal may exist at low temperature above the normal freezing point of water and high pressure greater than about 30 bars. A lot of quantities of natural gas hydrates exists in the earth and many production schemes are being studied. In the present investigation, depressurization method was considered to predict the production of gas and the simulation of the two phase flow - gas and water - in porous media is being carried out. The simulation show about the fluid flow in porous media have a variety of applications in industry. Results provide the appearance of gas and water production, the pressure profile, the saturation of gas/ water/ hydrates profiles and the location of the pressure front.

  • PDF

밸브에 의한 대형펌프시스템의 수격특성에 관한 연구 (A Study on Valve-Induced Water Hammer Characteristics for Large Pump System)

  • 이철재;임경선;조대환
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2009년도 춘계학술발표회
    • /
    • pp.177-178
    • /
    • 2009
  • 관로내의 유속이 급격히 변하면 압력도 크게 상승하거나 강하하게 되어 유체 과도현상을 일으키게 된다. 이러한 수격현상에 대한 연구는 펌프스테이션이 커지고 유체를 이송하는 시스템이 대형화되어 그 중요성이 더욱 증가하였다. 이것은 파이프라인이 길어지고 복잡해지기 때문이다. 이 연구에서는 특성법을 이용하여 대형펌프 시스템의 밸브 개폐로 발생하는 수격현상을 평가하였다.

  • PDF

수구동 액체이젝터를 이용한 농산물의 예냉특성에 관한 연구 (A Study on the Precool Characteristics of Agricultural Products Using the Water-driven Ejector)

  • 박영승;이정혜;김호영;김경근
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.45-49
    • /
    • 2001
  • To maintain the freshness of produce, because of stand away between produced and consumer, we need refrigeration system that can supply to consumer at cold chain as soon as gathering. General refrigeration system consist of refrigeration chamber or low temperature store. But the vacuum technology can rapidly refrigeration without refrigerator. This precool system possible to get low precooled temperature, suitable for the fishes, the meat, the vegetables, the fruit etc. Especially get advantage that quality maintain through rapid refrigeration of ferment directly generate heat. Vacuum precool system's principle is that water saturated temperature reduce according to pressure is get to vacuum area, so product temperature reduce as water evaporation at product. In vacuum suction, unit, on early experiment period run the rotary type vacuum pump at purpose pressure, then maintain pressure by water-diven ejector. As the results, cabbage took about 60 minutes to reach from $23.2^{\circ}C$ to $4.5^{\circ}C$at 5mgHg abs.

  • PDF

FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석 (Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube)

  • 강경호;윤병조;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

암모니아/물 흡수식 냉동기의 수직원관형 흡수기의 동적 모델 (Dynamic Model of a Vertical Tube Absorber for Ammonia/water Absorption Refrigerators)

  • 문현석;정은수;김병주
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.844-853
    • /
    • 2002
  • A dynamic model which simulates the coupled heat and mass transfer within a vertical tube absorber was developed. The liquid film is a binary mixture of two components, and both of these components are present in the vapor phase. The pressure, concentration, temperature and mass flow rate of the vapor are obtained by assuming that the pressure is uniform within an absorber. The model was applied to an absorber for an ammonia/water absorption refrigerator. The transient behaviors of the pressure, the outlet temperature and the concentration of the solution and the cooling water outlet temperature on a step change at the absorber inlet of the cooling water temperature, the vapor mass flow rate and the concentration of the solution were shown.

급수압에 따른 대변기 설비소음에 관한 연구 (A study on the Plumbing system noise of closet bowl by water supply pressure)

  • 김항;최은석;고광필;기노갑;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF

수압변동에 의한 포화 모래층의 액상화 연구 (A Study on the Liquefaction of Saturated Sand Layer under Oscillating Water Pressure)

  • Howoong Shon;Hyun-Chul Lim;Dae-Geun Lee
    • 대한지하수환경학회지
    • /
    • 제7권2호
    • /
    • pp.59-65
    • /
    • 2000
  • 변동수압에 의한 포화 사질층의 연직 간극수압 분포를 이론 및 실험적으로 연구하였다. 실험에 의해 모래표면에 작용하는 수압은 모래층으로 전달되며 진폭이 감쇠하고 상이 지연되며, 유효응력이 0이 되는 액상화 현상이 특별조건에서 발생한다. 이러한 실험결과는 탄성 대수층에 대한 지하수문제와 같은 이론으로 잘 설명된다. 해석에 의한 액상화의 주요 특징은 다음과 같다: 1)액상화 심도는 진폭 및 변동수압의 주파수 증가에 따라 증가한다. 2)수량(水量)의 증가와 모래층 내의 공기가 많아짐에 따라 액상화 심도가 증가한다. 특히, 공기의 적은 양도 액상화에 크게 영향을 미친다. 3) 압축율이 증가함에 따라 액상화 심도는 감소한다. 4)투수 계수값이 어느 특정값 이상이 되면 투수계수 값이 증가함에 따라 액상화 심도는 감소한다.

  • PDF

냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성 (Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller)

  • ;이근식
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1293-1300
    • /
    • 2011
  • 물 냉각기의 응축기와 증발기의 형상(길이, 관 직경, 관수, 통로 수)은 설비비용에 관련된 열전달 면적과 운전비용에 관련된 압력강하와의 조화로 결정될 수 있다. 물 냉각기 (냉동사이클)의 쉘-관 형상의 열교환기(응축기와 증발기)의 관 내부로 물이 통과할 때, 주어진 냉각부하와 요구조건을 만족하면서, 물 압력강하가 작은 설계조건에 초점을 맞추었다. 상업용 강화튜브의 사용과 상용 소프트웨어를 사용한 해석결과의 검증으로 실용성과 신뢰성 확보를 도모하였다. 해석결과, 관 통로 수를 적게, 관 직경을 크게, 관 수를 많게 선정하면, 관 길이를 짧게 하므로 물측 압력강하를 줄일 수 있었다. 그러나, 관수가 특정값보다 많을 때는 오히려 작은 관 직경을 사용하는 것이, 내부열저항의 감소로 인한 단위 길이 당 총열저항 감소 때문에, 관 길이를 짧게 하여 설비비용을 줄일 수 있었다.

물의 상평형 그림에 대한 오해와 이해: 대기 중 물의 증발과 얼음의 승화 (Misunderstanding and Understanding of the Phase Diagram for Water: Water Evaporation and Ice Sublimation in the Atmosphere)

  • 박종윤
    • 대한화학회지
    • /
    • 제51권6호
    • /
    • pp.577-584
    • /
    • 2007
  • 본 연구에서는 대기 중에서 물의 증발이나 얼음의 승화와 같은 물의 상태 변화를 물의 상평형 그 림을 이용하여 어떻게 설명할 수 있는지를 제시하고자 하였다. 물의 상평형 그림은 1성분계의 상평형을 나타 낸 것이므로 원칙적으로 물만 존재하는 경우에 사용할 수 있는 것이다. 공기가 존재하는 경우에는 액체 물 또 는 고체 얼음이 있으면 항상 공기 중에 수증기가 공존하게 되며, 이 때 물 또는 얼음의 압력은 공기 중 수증 기의 부분 압력과 일치하지 않기 때문에 상평형 그림에 하나의 점으로 그 상태를 나타낼 수 없다. 그러나 공 기가 존재하는 경우에도 포화 수증기압은 물만 존재하는 경우와 거의 차이가 없으므로 상평형 그림의 증기 압 력 곡선과 승화 곡선을 이용하여 대기 중에서 물의 증발과 얼음의 승화를 설명할 수 있음을 논의하였다.

수압변동에 의한 해저사질층의 액상화 현상연구 (LIQUEFACTION OF SAND SEABED INDUCED BY WATER PRESSURE WAVE)

  • 손호웅
    • 지구물리
    • /
    • 제4권3호
    • /
    • pp.197-203
    • /
    • 2001
  • 변동수압에 의한 해저 포화 사질틍의 연적 간극수압 분로를 이론 및 실험적으로 연구하였다. 실험에 의해 모래표면에 작용하는 수압은 모래층으로 전달되며 진폭이 감쇠하고 상이 지연되며, 유효응력이 0이 되는 액상화 현상이 특별 조건에서 발생한다. 이러한 실험결과는 탄성 대수층에 대한 지하수문제와 같은 이론으로 잘 설명된다. 해석에 의한 액상화의 주요 특징은 다음과 같다: 1)액상회 심도는 진폭 및 변동수압의 주파수 증가에 따라 증가한다. 2) 수량(水量)을 증가시키고 모래층 내의 공기가 많아짐에 따라 액상화 심도가 증가한다. 특히, 공기의 적은 양도 액상화에 크게 영향을 미친다. 3)압축율이 증가함에 따라 액상화 심도는 감소한다. 4)투수 계수값이 어느 특정값 이상이 되면 투수계수 값이 증가함에 따라 액상화 심도가 감소한다.

  • PDF