• Title/Summary/Keyword: Water Plan

Search Result 1,683, Processing Time 0.032 seconds

A Study on the Application Plan of Air-Conditioning and Renewable Complex Systems in the Small Schools. (소규모 학교의 냉난방 및 신재생에너지복합시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Hong, Sung-Hee;Kim, Seong-Sil;Hur, Inn-Ku;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.946-951
    • /
    • 2009
  • The research aims to study a new, optimum and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and water heating energy saving efficiencies for educational facilities. Therefore, this research carried out a study on the new/renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 174kW + solar heat collector $94\;m^2$ + highly efficient electronic cooling/heating device (EHP) 249.4kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 255.2kW + highly efficient electronic cooling/heating device (EHP) 168.2kW.

  • PDF

A Study on the Application Plan of Air-Conditioning and New and Renewable Systems in the Large High Schools (대규모 고등학교의 냉난방 및 신재생에너지시스템 적용방안에 관한 연구)

  • Kim, Ji-Yeon;Park, Hyo-Soon;Kim, Seong-Sil;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.564-574
    • /
    • 2009
  • The study is conducted to study a new, optimum and new and renewable energy application method that can cover the minimum energy and operation costs within a range of school budgets. By deriving the optimum application method, it is expected to maximize the cooling/heating and hot water supply energy saving efficiencies for educational facilities. Therefore, this research implemented a study on the new and renewable energy utilization technique diffusion expansion method and the optimum method. As a result, the first optimum plan was introduced with the multi-type geothermal heat pump 475.6 kW+highly efficient electronic cooling/heating device(EHP) 545.2 kW. On the other hand, the second optimum plan was induced as the multi-type geothermal heat pump 261kW+solar heat collector $240\;m^2$+highly efficient electronic cooling/heating device(EHP) 759.8 kW.

A Study on the Planning Indicator for Carbon Neutral Green City (탄소중립 녹색도시 구현을 위한 계획지표 설정에 관한 연구)

  • Kim, You-Min;Lee, Joo Hyung
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this dissertation is establishing internal indicator list for achieving policy goal of Carbon Neutrality Green City. First of all, it started to construct the basic system of planning indicator based on through comprehension of current studies such as advanced researches, government guidelines and green building certifications. And then it was set up final indicator list through inspecting FGI (Focus Group Interview), Verification of suitability, and Analysis of importance). As a result of this research, the planning indicator divided three steps and there were classified four fields in the top-level; Green Land and Ecology, Green Energy, Green Resource and Transportation, Green Living and Institution. According to the data, it deducted four items (ratio of green land, site plan, heat island and management of climate, base of nature ecology) and twelve index in the field of green land and ecology, three item(energy conservation and self-supporting, energy efficiency, new regeneration energy) and twelve index in the field of green energy and regeneration, five items(water resources utilize and circulation, other resource reduction and circulation, public transportation, green transportation plan) and fifteen index. Totally, Planning Indicators of forty nine were deducted. Therefore, there was the result of importance analysis that the indicators of plan and maintain management as the side of space for carbon neutrality were more appreciated than carbon reduction of individual building.

A Qualitative Understanding of the Critical Opinion and Environmental Values of College Students meeting the Young-Wall Dam Issue (영월댐 건설 문제를 둘러 싼 환경교육과 학생들의 비판적 견해와 환경가치에 대한 정성적 이해)

  • 구수정
    • Hwankyungkyoyuk
    • /
    • v.12 no.1
    • /
    • pp.276-293
    • /
    • 1999
  • An environmentally hot issue has arisen from the plan of Young-Wall Dam Construction at Tong river in Korea lately. The point at issue is which value is bigger between the water conservation for human use in future and the ecosystem protection for the intrinsic value of nature including animals and plants there. The purpose of this study is in the qualitative understanding of college students' critical thinking ability and opinion and the environmental values of them through the analysis of their writings. Various environmental values written in the 7th revised national curriculum of Korea are used as a criteria to investigate students' environmental values in their written opinions. Various environmental values are shown up to be handled such as the anthropocentrism, ecocentrism, pro-technology etc. Students of Dept. of Environment Teaching in the Kongju National University are the subject of this study. It shows that they have a deep understanding of the Young-Wall Dam issue and assert their opinions objectively and critically. Most of them(89.5%, n=17) are against the constructional plan of the Young-Wall Dam. Students who are for the plan are proved to have pro-technology value only and the others who are against to have various values including deer ecology.

  • PDF

A Study on Establishment of Mitigation Technique of Deterioration for Environmental-friendly Dam Construction in Rural Area - A focus of the Plant Ecosystem - (농촌지역내 친환경적인 댐 조성을 위한 훼손저감기법 적용 연구 - 식물생태계를 중심으로 -)

  • Lee, Soo-Dong;Kang, Hyun-Kyung
    • Journal of Korean Society of Rural Planning
    • /
    • v.16 no.2
    • /
    • pp.31-45
    • /
    • 2010
  • Building a dam that is not considering the environmental impact and human social impact can cause the loss of entire ecospheres such as fragmentary green network, disturbance of plants ecosystem, the destruction of social and cultural indigenous resources, therefore, it can occur the environment change and distortion of ecosystem. The purpose of this study is that presenting the methods of ecosystem maintenance and ecosystem damage compensation about for environmentally direct impact i.e. the ecosystem change in the intended place for building a dam. According to the planning progress, the study was proceeded to planning site examine, assessment, conception plan. As the results of examine and assessment, it must be necessary to offered the maintenance and damage compensation if the site where include the 1st degree of biotope area, the 2nd degree of biotope and the 8th degree of green naturality area were damaged by being submerged and constructing road. In addition, according to the conception plan, we suggest the mitigation proposals such as plant communities transplant, planning of connecting green network against for influencing direct impact ecosystem that is destroying plant communities, damaging inhabitants, noise pollution, water pollution, etc.

A Study on the Landscape Change and Management Plan for Seomjin River Chimsil Wetland through Aerial Photograph and Sediment Analysis (항공사진 및 퇴적물 분석을 통한 섬진강 침실습지 경관변화와 관리방안)

  • Lee, Seong-Ho;JANG, Dong-Ho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.3
    • /
    • pp.25-39
    • /
    • 2020
  • This study analyzed the management plan of Seomjin River Chimsil Wetland by identifying landscape changes through aerial photographs analysis and concentrations of sedimentation. Geophysical Landscape Change Analysis showed that vegetation accounts for more than half of the total area. The Barren land and water body was somewhere repeatedly increased and decreased and made an irregular form in the study area. The soil was acidic, and no eurtophication was shown, but it was potential to form wetland. In addition, the research area has been terrestrification of sand bar for a long period of time, forming a soil layer. Although the characteristics of river deposits were shown in the study area, the grain size was a particulate matter, and the sorting was 'very poorly sorted'. In some areas of Seomjin River Chimsil Wetland, sand bars were formed, but most areas were undergoing to terrestrification. Therefore, in order to preserve the riverine area and to serve by a bridge between the land ecosystem and the underwater ecosystem, it is very necessary to remove some vegetation, create a proper waterway, and restore the wetland.

Influences of Fish Farm on the Physicochemistry of Stream Water Quality in Mt. Baegun Area(III) (백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(III))

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.4
    • /
    • pp.46-55
    • /
    • 2001
  • Analysis of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Baegun area were monitored seasonally for three years. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. As a result of regression analyses, the linear equation of pH of influent and effluent water of fish farm was, pH of effluent water of fish farm = $0.6234{\times}pH$ of influent water of fish farm + 2.6263. Also, the linear equation of electrical conductivity of influent and effluent water of fish farm was electrical conductivity of effluent water of fish farm = $1.7275{\times}$electrical conductivity of influent water of fish farm - 14.007. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and water temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, total amount of cation and total amount of anion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as environmentally-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

Prioritization decision for hazard ranking of water distribution network by cluster using the Entropy-TOPSIS method (Entropy-TOPSIS 기법을 활용한 군집별 상수도관망 위험도 관리순위 결정)

  • Park, Haekeum;Kim, Kibum;Hyung, Jinseok;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.517-531
    • /
    • 2021
  • The water supply facilities of Korea have achieved a rapid growth, along with the other social infrastructures consisting a city, due to the phenomenon of urbanization according to economic development. Meanwhile, the level of water supply service demanded by consumer is also steadily getting higher in keeping with economic growth. However, as an adverse effect of rapid growth, the quantity of aged water supply pipes are increasing rapidly, Bursts caused by pipe aging brought about an enormous economic loss of about 6,161 billion won as of 2019. These problems are not only worsening water supply management, also increasing the regional gap in water supply services. The purpose of this study is to classify hazard evaluation indicators and to rank the water distribution network hazard by cluster using the TOPSIS method. In conclusion, in this study, the entropy-based multi-criteria decision-making methods was applied to rank the hazard management of the water distribution network, and the hazard management ranking for each cluster according to the water supply conditions of the county-level municipalities was determined according to the evaluation indicators of water outage, water leakage, and pipe aging. As such, the hazard ranking method proposed in this study can consider various factors that can impede the tap water supply service in the water distribution network from a macroscopic point of view, and it can be reflected in evaluating the degree of hazard management of the water distribution network from a preventive point of view. Also, it can be utilized in the implementation of the maintenance plan and water distribution network management project considering the equity of water supply service and the stability of service supply.

Improvement and Problem of Water Management in Korea (우리나라 물 관리의 문제점과 발전방안)

  • Park, Jong Gwan
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.538-547
    • /
    • 2017
  • Korea's water management system is typically a multi-ministerial system, so its efficiency is declining. In order to propose current state and improvement plan of the water management in Korea, this study discussed the improvement of central and local water management. The water management problems are lack of water policy coordination system, conflicts between ministries due to function of water quantity, water quality and agricultural water, redundant investment and inefficiency, insufficient recognition of water autonomy, concentrated central management and deepening regional disparities, lack of financial resources, etc. Hence, improvement to solve the problem includes strengthening the coordination of water management functions between ministries, transferring water management functions of central ministries and strengthening local capacity, and desirable role allocation of central and local governments. In addition, improvement at the local include efforts to change awareness of the water detailed and get water autonomy, integrate management of the watershed, strengthen the local community, secure financial resources, etc.

Risk Assessment of Drinking Water Pollutants (다중이용시설에서의 먹는물 위해성 평가)

  • Back, Young Maan;Chung, Yong;Park, Je Chul;Kim, Hyung Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1107-1108
    • /
    • 2006
  • As expanding municipal and industrial areas since started the economic development plan in earnest in 1970's, the water resource, mainly river surface water has been seriously polluted. Nevertheless, being upgraded in their treatment technologies for the drinking water, the safety has been issued one of crucially social problem in Korea. The water authorities has tried to improve the quality such as amending the drinking water quality standard to be monitored; hazardous chemicals and microorganis have been added and now 55 items, before 47 items, since in 2002. The Water Authorities of Seoul, the capital city of Korea, planned to assess the safty of drinking water quality after amended the standard. This study was conducted to assess the risk due to polluted chemicals including 21 heavy metals, VOCs, pesticides, PAHs, DBPs and organic chemicals among the regulated items. The risk assessment were undertaken hazard identification, exposure assessment, dose-response assessment and risk characterization. For the exposoure assessment, tap water, bottled water and purified water were sampled and analyzed in February, 2004. Risk characterization of detected chemicals was categorized into carcinogenecity and noncarcinogenecity, and estimated the excess of carcinogens and compapared with the reference dose (RfD) of noncarcinogenns. The excess risk of carcinogens from samples were considered comparatively in the acceptable levels; $10^{-6}$ for cancer risk and hazard quotient (HQ) 1.0 for noncancer risk. The deteced levels were estimated in $10^{-5}{\sim}10^{-6}$ of cancer risk and below 1.0 of HQ of noncancer risk. While three kinds of water were determined within the acceptal levels, DBPs were detected in tap water and purified were and some undesireable chemicals such as more fluoride detected rather than the quality stanadard. For the drinking water safety, it shoud be continuously monitored, assessed and managed as well risk communiction between the authoritis and public.