• Title/Summary/Keyword: Water Level Monitoring

Search Result 647, Processing Time 0.033 seconds

THE CASPIAN SEA LEVEL, DYNAMICS, WIND, WAVES AND UPLIFT OF THE EARTH'S CRUST DERIVED FROM SATELLITE ALTIMETRY

  • Lebedev, S.A.;Kostianoy, A.G.
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.973-976
    • /
    • 2006
  • The oscillations of the Caspian Sea level represent a result of mutually related hydrometeorological processes. The change in the tendency of the mean sea level variations that occurred in the middle 1970s, when the long-term level fall was replaced by its rapid and significant rise, represents an important indicator of the changes in the natural regime of the Caspian Sea. Therefore, sea level monitoring and long-term forecast of the sea level changes represent an extremely important task. The aim of this presentation is to show the experience of application of satellite altimetry methods to the investigation of seasonal and interannual variability of the sea level, wind speed and wave height, water dynamics, as well as of uplift of the Earth’s crust in different parts of the Caspian Sea and Kara-Bogaz-Gol Bay. Special attention is given to estimates of the Volga River runoff derived from satellite altimetry data. The work is based on the 1992-2005 TOPEX/Poseidon (T/P) and Jason-1 (J-1) data sets.

  • PDF

Water Quality Monitoring for Hazard Analysis in Aquaculture Farm of Rainbow Trout (송어양식장의 위해요소 관리를 위한 수질 모니터링)

  • Kim, Young-Mog;Lee, Myung-Suk;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.4
    • /
    • pp.819-827
    • /
    • 2013
  • Water quality has been considered to be one of sanitation standard operating procedures (SSOP) for hazard analysis critical control points (HACCP) application in aquaculture farms. This study was conducted to evaluate a hazard caused by water used in aquaculture farm of rainbow trout. The water quality was analyzed to investigate both physiochemical and bacteriological level in water samples collected from aquaculture farm of rainbow trout, Oncorhynchus mykiss. No significant difference were observed on water temperature and pH from season to season. However, the levels of dissolved oxygen were decreased as the outside temperature was increased, even if the levels were adequate for aquaculture. Also, other physiochemical analysis including biochemical oxygen demand (BOD), chemical oxygen demand (COD) and suspended solid (SS) revealed that the waters for aquaculture analyzed in this study was suitable for rainbow trout aquaculture. The bacterial analyses were also revealed that the waters for aquaculture were met to both coliform group (<18 MPN/100mL) and viable cell count (<100 CFU/mL). However, some of waste waters from aquaculture farms showed higher levels of BOD and COD than those of waste water standard (<2 ppm), suggesting that regular cleaning of fish tank and precipitation tank is needed.

Current Status of Alien Plants in the Reservoir Shoreline in Korea (우리나라 저수지 호안에서 외래식물의 현황)

  • Cho, Hyunsuk;Cho, Kang-Hyun
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.274-283
    • /
    • 2015
  • The reservoir shores seem to be vulnerable to biological invasion. The purpose of this research was to find out the floristic composition of alien plants and their relationship between environmental factors on reservoir shorelines in Korea. We investigated flora of alien plants and environmental factors of geomorphology, hydrology, water quality and soil on the shoreline of a total of 35 reservoirs with different water level managements. There were 56 species of alien plants, which was 15% of the total plant species identified in the study of reservoirs. A total of 57% of these alien species were the species which were introduced shortly after opening the port from 1876 to 1921 in Korea. More than 80% of the alien plants on the reservoir shores originated from America and Europe. The current distribution of Ambrosia trifida and Paspalum distichum were restricted in the central part and the southern region of the Korean Peninsula, respectively. The water level fluctuation, flood frequency at the median water level, water pollution index, coverage of rock exposure and mean degree of shoreline slope were determined as important environmental factors that have an effect on the characteristics of shoreline alien flora. Our results suggest that the reservoir shore was in danger of being invaded by alien plants due to the water level management and other human disturbances. For effective conservation of the reservoir ecosystem, periodic monitoring systems are required for the early detection of alien species on the reservoir shore.

Development of Measuring Method for Bridge Scour and Water Level Using Temperature Difference Between Medium Interfaces (매질 경계면의 온도 변화를 이용한 교량 세굴 및 수위 측정방법 개발)

  • Joo, Bong-Chul;Park, Ki-Tae;You, Young-Jun;Hwang, Yoon-Koog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.126-133
    • /
    • 2014
  • The main source of bridge destruction is due to scour. The bridge scour is the result of erosive action of flowing water taking away ground materials from near the abutment or pier. Furthermore, the water level must be also monitored whiling flooding, because it dangers not only the stability of bridge itself, but the safety of bridge users. This study is intended to develop a new measuring system for bridge scour by overcoming the current limitation of scour measurement technique. This measuring system is confirmed its excellence and validity through this study. The newly developed measuring system finds the distance between the water surface and the ground surface by detecting temperature difference along the abutment vertically. The measuring mechanism for monitoring the bridge scour and water level is based on identifying the temperature difference among mediums, including air, water and ground. In order to validate the new measuring system, the lab experiments and the field tests are conducted and compared. It has been confirmed that this system can effectively measure the bridge scour and the water level by analyzing the temperature distribution between mediums and the temperature variation over time.

A Case Study of Measuring Residual Groundwater Level on Reclaimed and Dredging Clay Layer (준설점토 지반상 잔류 지하수위의 계측 사례 연구)

  • Yang Tae-Seon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.7
    • /
    • pp.63-72
    • /
    • 2005
  • Grounwater level applied on dredged and reclaimed clay layer was assumed to be the same value under design criterion as field test one, but actually differences are found through the monitoring test. In this study, a case study of measuring residual groundwater level is performed in ground improvement construction of Gwangyang container terminal and hinterland. With priority given to residual groundwater level measured during construction and management period of 9 years, it is investigated that residual groundwater level (R. GWL) could be applied reasonably to the design, construction, and use stages of the container harbor and land development.

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Burden of Disease Attributable to Inadequate Drinking Water, Sanitation, and Hygiene in Korea

  • Kim, Jong-Hun;Cheong, Hae-Kwan;Jeon, Byoung-Hak
    • Journal of Korean Medical Science
    • /
    • v.33 no.46
    • /
    • pp.288.1-288.12
    • /
    • 2018
  • Background: Diarrheal and intestinal infectious disease caused by inadequate drinking water, sanitation, and hygiene (WASH) is not only a great concern in developing countries but also a problem in low-income populations and rural areas in developed countries. In this study, we assessed the exposure to inadequate WASH in Korea and estimated the burden of disease attributable to inadequate WASH. Methods: We used observational data on water supply, drinking water, sewage treatment rate, and hand washing to assess inadequate WASH conditions in Korea, and estimated the level of exposure in the entire population. The disease burden was estimated by applying the cause of death data from death registry and the morbidity data from the national health insurance to the population attributable fraction (PAF) for the disease caused by inappropriate WASH. Results: In 2013, 1.4% of the population were exposed to inadequate drinking water, and 1.0% were living in areas where sewerage was not connected. The frequency of handwashing with soap after contact with excreta was 23.5%. The PAF due to inadequate WASH as a cluster of risk factors was 0.353 (95% confidence interval [CI], 0.275-0.417), among which over 90% were attributable to hand hygiene factors that were significantly worse than those in American and European high-income countries. Conclusion: The level of hand hygiene in Korea has yet to be improved to the extent that it shows a significant difference compared to other high-income countries. Therefore, improving the current situation in Korea requires a continuous hand washing campaign and a program aimed at all people. In addition, continuous policy intervention for improvement of sewage treatment facilities in rural areas is required, and water quality control monitoring should be continuously carried out.

Monitoring and Characterization of Bacterial Contamination in a High-Purity Water System Used for Semiconductor Manufacturing

  • Kim, In -Seop;Lee, Geon-Hyoung;Lee, Kye-Joon
    • Journal of Microbiology
    • /
    • v.38 no.2
    • /
    • pp.99-104
    • /
    • 2000
  • Hydrogen peroxide has been used in cleaning the piping of an advanced high-purity water system that supplies ultra-high purity water (UHPW) for 16 megabyte DRAM semiconductor manufacturing. The level of hydrogen peroxide-resistant bacteria in UHPW water was monitored prior to and after disinfecting the piping with hydrogen peroxide. Most of the bacteria isolated after hydrogen peroxide disinfection were highly resistant to hydrogen peroxide. However, the percentage of resistant bacteria decreased with time. The hydrogen peroxide-resistant bacteria were identified as Micrococcus luteus, Bacillus cereus, Alcaligenes latus, Xanthomonas sp. and Flavobacterium indologenes. The susceptibility of the bacteria to hydrogen peroxide was tested as either planktonic cells or attached cells on glass. Attached bacteria as the biofilm on glass exhibited increased hydrogen peroxide resistnace, with the resistance increasing with respect to the age of the biofilm regrowth on piping after hydrogen peroxide treatment. In order to optimize the cleaning strategy for piping of the high-purity water system, the disinfecting effect of hydrogen preoxide and peracetic acid on the bacteria was evaluated. The combined use of hydrogen peroxide and peracetic acid was very effective in killing attached bacteria as well as planktonic bacteria.

  • PDF

Analyzing effect and importance of input predictors for urban streamflow prediction based on a Bayesian tree-based model

  • Nguyen, Duc Hai;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.134-134
    • /
    • 2022
  • Streamflow forecasting plays a crucial role in water resource control, especially in highly urbanized areas that are very vulnerable to flooding during heavy rainfall event. In addition to providing the accurate prediction, the evaluation of effects and importance of the input predictors can contribute to water manager. Recently, machine learning techniques have applied their advantages for modeling complex and nonlinear hydrological processes. However, the techniques have not considered properly the importance and uncertainty of the predictor variables. To address these concerns, we applied the GA-BART, that integrates a genetic algorithm (GA) with the Bayesian additive regression tree (BART) model for hourly streamflow forecasting and analyzing input predictors. The Jungrang urban basin was selected as a case study and a database was established based on 39 heavy rainfall events during 2003 and 2020 from the rain gauges and monitoring stations. For the goal of this study, we used a combination of inputs that included the areal rainfall of the subbasins at current time step and previous time steps and water level and streamflow of the stations at time step for multistep-ahead streamflow predictions. An analysis of multiple datasets including different input predictors was performed to define the optimal set for streamflow forecasting. In addition, the GA-BART model could reasonably determine the relative importance of the input variables. The assessment might help water resource managers improve the accuracy of forecasts and early flood warnings in the basin.

  • PDF

Modeling Artificial Groundwater Recharge in the Hancheon Drainage Area, Jeju island, Korea (제주도 한천유역 지하수 모델개발을 통한 인공함양 평가)

  • Oh, Se-Hyoung;Kim, Yong-Cheol;Koo, Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.34-45
    • /
    • 2011
  • For the Hancheon drainage area in Jeju island, a groundwater flow model using Visual MODFLOW was developed to simulate artificial recharge through injection wells installed in the Hancheon reservoir. The model was used to analyze changes of the groundwater level and the water budget due to the artificial recharge. The model assumed that $2{\times}10^6m^3$ of storm water would recharge annually through the injection wells during the rainy season. The transient simulation results showed that the water level rose by 39.6 m at the nearest monitoring well and by 0.26 m at the well located 7 km downstream from the injection wells demonstrating a large extent of the affected area by the artificial recharge. It also shown that, at the time when the recharge ended in the 5th year, the water level increased by 81 m at the artificial reservoir and the radius of influence was about 2.1 km downstream toward the coast. The residence time of recharged groundwater was estimated to be no less than 5 years. The model also illustrated that 15 years of artificial recharge could increase the average linear velocity of groundwater up to 1540 m/yr, which showed 100 m/yr higher than before. Increase of groundwater storage due to artificial recharge was calculated to be $2.4{\times}10^6$ and $4.3{\times}10^6m^3$ at the end of the 5th and 10th years of artificial recharge, respectively. The rate of storage increase was gradually diminished afterwards, and storage increase of $5.0{\times}10^6m^3$ was retained after 15 years of artificial recharge. Conclusively, the artificial recharge system could augment $5.0{\times}10^6m^3$ of additional groundwater resources in the Hancheon area.