• Title/Summary/Keyword: Water Drop

Search Result 910, Processing Time 0.029 seconds

The Investigation on the Optimum Culture Conditions and the Ice Nucleating Activity of Bacterium Xanthomonas translucens KCTC 2751 (Xanthomonas translucens KCTC 2751의 최적배양과 빙핵 활성 검토)

  • Kim, Young-Mun;Kang, Sung-Il;Jang, Young-Boo;Jun, Byung-Jin;Kong, Jai-Yul
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.249-255
    • /
    • 2006
  • The optimum culture conditions for the ice nucleating activity and the cell growth of Xanthomonas translucens KCTC 2751 were investigated. The optimum initial pH and temperature for the cell growth and the ice nucleating activity were 6.5 and $25^{\circ}C$, respectively. The optimum culture medium for the ice nucleating activity was composed of 1.0% maltose, 1.4% yeast extract, 0.8% digested of gelatin, and 0.03% KCI in distilled water. Freezing operations carried out on distilled water showed that the degrees of supercooling were $-7.90^{\circ}C$ without ice nucleators, $-1.56^{\circ}C$ with silver iodide as a commercial ice nucleator, and $-1.36^{\circ}C$ when Xanthomonas translucens KCTC 2751 were added. During progressive freeze-concentration assays, the addition of Xanthomonas translucens KCTC 2751 led to lower saccharose concentrations in the crystals, while the cells led to higher saccharose concetrations in the concentrated phase.

Study on Optimum Condition of Water-Repellent Finishing For PPS Fabrics (PPS 원단의 발수가공을 위한 최적의 가공조건 고찰)

  • Lee, In-Yeol;Jeong, Go-Eun;Lee, Stephen
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.47-47
    • /
    • 2011
  • 국내의 기능성 난연성 섬유 제조기술은 원사 자체에 난연제가 포함된 상태인 난연 PET 원사나, 일반 PET 원단에 후방염 처리한 원단이 사용되기에 난연 방염성능이 만족스럽지 못하고 친환경적이지 못한 실정이다. 오늘날 세계 난연섬유 시장 규모는 10조원에 이르고 있으며 국내에서도 화재에 대한 경각심이 높아지는 추세이므로 기능성을 갖춘 고부가가치 난연소재의 개발이 시급하다. 폴리페닐렌술피드(PPS)는 내열성 및 내화학약품성이 뛰어난 열가소성 고분자로 용융방사가 가능하다. 난연성이 높은 양모섬유 또는 아크릴계 난연섬유, 아라미드 섬유 등은 비용 문제로 범용화에 한계가 있으므로 비교적 저렴한 PPS 섬유가 개발될 경우 범용화를 기대할 수 있다. 현재는 PPS 섬유가 특수한 용도에 주로 사용되고 있으나 우수한 난연 특성을 이용하여 일반 용도로의 사용 및 수요가 급격히 늘어날 것으로 예상되며 우선적으로 인테리어용 원단, 특히 커튼이나 소파용 원단으로 용도 전개가 가능할 것으로 판단하였다. 본 연구에서는 소파용 PPS 원단의 후가공 조건의 선정 및 불소계 발수방오가공을 위한 최적의 조건을 선정하고자 하였다. Padding(wet pick up율 $80{\pm}3%$)-Drying($105^{\circ}C$, 2.5min)-Curing은 시간은 1분으로 고정시킨 후, 온도를 150, 160, 170, 180, 190, $200^{\circ}C$에서 처리하여 Yellowness값을 측정한 결과, 온도가 높아질수록 Yellowness값이 커지는 것으로 미루어 보아 PPS원단은 높은 열에 영향을 받아 황변 현상이 일어나는 것으로 사료된다. 특히 $180^{\circ}C$를 기점으로 값에 큰 변화를 보였으므로 최적의 열처리 온도는 $170^{\circ}C$로 선정하여 이후의 실험을 진행하였다. 또한 큐어링 시간이 황변에 미치는 영향을 분석한 결과 온도에 의한 영향에 비해 적은 편으로 사료되었으나, 1.5min을 기점으로 Yellowess값이 높아졌으므로 최적의 열처리 시간을 1분으로 선정하였다. 최종 가공조건인 $170^{\circ}C$, 1분에서 처리한 시험포는 처리전 원단과 비교하였을 때, ${\Delta}$Yellowness가 2.84 정도로 나타났다. 그 후, PPS 원단에 불소가공제 (TG-991N, 동인텍스켐)의 적정 농도를 선정하기 위해 1~7%까지 농도를 높이며 처리한 결과, 불소가공제의 농도가 높아짐에 따라 황변현상이 나타남을 알 수 있었다. 농도가 높아짐에 따라 Yellowness값은 증가하다가 4% 이후 완만해지는 것을 알 수 있었으므로 IPA/Water Drop test와 발수도시험 (KS K 0590;2008)을 통해 적정 농도를 선정하였다. PPS 원단은 불소가공제의 농도가 높아짐에 따라 발수도가 우수해졌으며, 가공제 농도 3% 처리만으로도 우수한 발수도를 나타내었으나 100% 발수를 위해서는 가공제 농도가 5% 이상 처리되어야 하는 것을 확인할 수 있었다.

  • PDF

A Study on Drop Shaft Bottom of Maximum Pressure of the Deep Tunnel by Stilling Basin of Depth (대심도 터널의 수직 유입구 감세지 깊이에 따른 바닥면 최대압력 비교 연구)

  • OH, Jun Oh;Park, Jae Hyeon;Park, Chang Keun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.74-74
    • /
    • 2015
  • 최근 홍수의 특성과 피해 양상은 과거와는 다르게 변화하고 있으며, 급격한 도시화로 인하여 기존 하천유역의 저류 능력이 감소하였으며 이러한 한계를 극복하기 위하여 이미 외국에서는 대심도 터널을 활용한 홍수재해 관리방안이 오래전부터 활용되어 왔다. 본 연구에서는 대심도 터널의 유입구, 수직갱, 감세지, 배수터널과 같은 시설물 중 대심도 터널 설계 시 수직 유입구를 통해 유입되는 유량의 에너지를 완화하고 효과적으로 배수 할 수 있도록 중요한 역할을 하는 감세지의 효율적인 깊이 산정을 위하여 수리모형실험을 실시하였으며, 모형은 Froude 상사법칙을 사용하여 원형의 1/18크기로 제작하였다. 본 연구에서 실시한 감세지 모형의 깊이는 0.278 m(원형 5.0 m), 0.417 m(원형 7.5 m)이며, 각 감세지 깊이별 수직 유입구 3개소(저지수직구1, 저지수직구2, 고지수직구) 및 5가지의 유량 CASE에 대하여 감세지 바닥면 압력을 비교?분석 하였다. 수직 유입구 3개소의 설계조건에 따른 감세지 깊이별 바닥면 압력 분포 평가를 실시한 결과 저지수직구1의 감세지 깊이 0.278 m(원형 5.0m)에서는 최대 압력이 4번 지점에서 $0.075kg/cm^2$(원형 1.30 MPa)이 측정 되었으며, 0.417 m(원형 7.5m)에서는 최대 압력이 1번지점에서 $0.089kg/cm^2$(원형 1.54MPa)이 측정되었다. 또한 저지수직구2의 감세지 깊이 0.278 m(원형 5.0 m)에서는 최대 압력이 1번 지점에서 $0.074kg/cm^2$(원형 1.28 MPa)이 측정 되었으며, 0.417 m(원형 7.5 m)에서는 최대 압력이 2번지점에서 $0.088kg/cm^2$(원형 1.52 MPa)이 측정되었다. 고지수직구의 감세지 깊이 0.278 m(원형 5.0 m)에서는 최대 압력이 3번 지점에서 $0.082kg/cm^2$(원형 1.42 MPa)이 측정 되었으며, 0.417 m(원형 7.5 m)에서는 최대 압력이 1번지점에서 $0.092kg/cm^2$(원형 1.59 MPa)이 측정되었다. 본 연구에서 실시한 수리모형실험의 결과 저유량에서 고유량으로 갈수록 최대압력지점은 반시계방향으로 움직이는 것을 알 수 있으며, 이는 수직 유입구의 설계조건에 따른 수직갱에서의 회전수차에 의하여 발생하는 것으로 분석하였다. 따라서 적절한 감세지 깊이 산정을 위해서 대심도터널의 수직 유입구(유입구형태, 수직갱)의 평가가 함께 유기적으로 이루어져야 할 것으로 판단된다.

  • PDF

The Cooling Water Bypass Ratio of Packing in Plume Abatement Cooling Tower of a Combined Cycle Power Plant During Winter Operation (복합화력발전소 동계운전시 백연방지 냉각탑 냉각수의 충전재 바이패스 비율 확인)

  • Chung, Hee-Bong;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.33-38
    • /
    • 2018
  • In this study, it was confirmed whether the cooling water bypass ratio of packing for plume abatement matched designed value during winter operation of combined cycle power plant. Designed operating wet bulb temperature of the plume abatement cooling tower with 29 Gcal/h capacity had a range from $13^{\circ}C$ to $-20^{\circ}C$, while its designed bypass ratio was from 0 % to 78%, so that increasing rate of the designed bypass ratio was $2.36%/^{\circ}C$ when the external temperature decreased. When the wet bulb temperature at cooling tower inlet had a range from $7.8^{\circ}C$ to $-11.8^{\circ}C$ in a normal operation, it was measured that actual bypass ratio of packing for plume abatement had a range from 23.8 % to 74.3%. While increasing rate of the actual bypass ratio was $2.71%/^{\circ}C$ in a range from $7.8^{\circ}C$ to $-9.55^{\circ}C$, it was $1.61%/^{\circ}C$ under $-10^{\circ}C$ in cold weather condition according to atmospheric temperature drop, therefore it was confirmed that the increasing rate of the bypass ratio for packing was lowered than its design.

  • PDF

Synthesis and Characterization of Interfacial Properties of Glycerol Surfactant (글리세롤계 계면활성제 합성 및 계면 특성에 관한 연구)

  • Lim, JongChoo;Lee, Seul;Kim, ByeongJo;Lee, JongGi;Choi, KyuYong
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.376-383
    • /
    • 2011
  • The CMCs of LA and LA3 nonionic surfactants obtained from the reaction between glycidol and lauryl alcohol were found to be $0.97{\times}10^{-3}mol/L$ and $1.02{\times}10^{-3}mol/L$ respectively and the surface tensions for 1 wt% surfactant were 26.99 and 27.48 mN/m respectively. Dynamic surface tension measurements using a maximum bubble pressure tensiometer showed that the adsorption rate of surfactant molecules at the interface between the air and the surfactant solution was found to be relatively fast in both surfactant systems, presumably due to the high mobility of surfactant molecules. The contact angles of LA and LA3 nonionic surfactants were 27.8 and $20.9^{\circ}$ respectively and the dynamic interfacial tension measurement by a spinning drop tensiometer showed that interfacial tensions at equilibrium condition in both systems were almost the same. Also both surfactant systems reached equilibrium in 2~3 min. Both surfactant solutions showed high stability when evaluated by conductometric method and the LA nonionic surfactant system provided the higher foam stability than the LA3 nonionic surfactant system. The phase behavior experiments showed a lower phase or oil in water (O/W) microemulsion in equilibrium with an excess oil phase at all temperatures studied. No three-phase region was observed including a middle-phase microemulsion or a lamellar liquid crystalline phase.

An analysis of hydraulic characteristics of stepped boulder fishway installed in mountain stream (산지하천에 설치된 계단식 전석 어도의 수리 특성 분석)

  • Kim, Ki Heung
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.1
    • /
    • pp.99-109
    • /
    • 2022
  • This study was intended to suggest the applicability of stepped boulder fishway using the concept of traditional boulder weir, focusing on the problems of existing concrete pool-and-weir fishways installed in mountain streams. To achieve this purpose, a stepped boulder fishway was designed and constructed as a pilot project in consideration of ascending capacity of the selected target fishes. Under the given discharge conditions, the hydraulic characteristics of the fishway were investigated in the field, and the characteristics and ascending capacity of the fishes were compared and analyzed. The fishway had a short length and steep slope, but the mean drops between each baffle were the range of 0.15 to 0.29 m, and this range satisfied the limit condition of about 0.40 m, which was in the limit of the drop that target fishes can ascend. The mean velocities of each baffle and pool were 0.82 to 0.87 m/sec and 0.13 to 0.24 m/sec. This result satisfied the conditions of burst speed (10 to 30 times of body length) and mean velocity of the resting pool (7 to 25% of burst speed) for target fishes. Since the bottom surface of the pool formed of boulders had a gentle reverse slope and rotational flow did not occur, the efficiency of fishway can be increased, and it will also be possible to solve the maintenance problem by flushing bed materials.

Development of Gold Amalgam Voltametric Microelectrode for the Quantification of O2, Fe2+, Mn2+, and HS- (퇴적물 공극수내 O2, Fe2+, Mn2+ 및 HS- 센싱을 위한 금아말감 미세전극 개발)

  • Kwon, Soongil;Park, Donggeun;Choi, Geunyoung;Sung, Jaebin;Kim, Hyunsoo;Lee, Jae Woo;Hong, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.2
    • /
    • pp.103-112
    • /
    • 2022
  • A gold amalgam voltammetric microelectrode (GAVM) system was developed for the quantification of dissolved biogeochemical species, such as O2, Fe2+, Mn2+, and HS- in sediment porewater. Commercially available Ag/AgCl and platinum electrodes were used as the reference and counter electrode, respectively, and a gold amalgam microelectrode was fabricated in the laboratory using 150-um diameter gold wire and a borosilicate capillary tube with a 1.6-mm diameter. A portable potentiostat (Metrohm, DropSens) was used for the application of voltage sweeping and to acquire the electric current. For sediment profiling, a commercially available actuator was customized and modified. The analysis method used in the system used the most widely used analysis method among the electrochemical analysis currently used The GAVM system was successively calibrated with the species and applied to estuarine sediments. The porewater analysis showed that the oxygen concentration was decreased to zero at a depth of 0.6 mm, and maximum Mn2+ and Fe2+ concentrations of 50 uM and 20 uM were detected at 2 and 3-cm depths, respectively. Maximum HS- concentrations of 10 uM were detected at 4 cm in the deeper sediments. The GAVM system was successfully developed and applied to the sediment and can be used to better understand biogeochemical reactions.

Experimental and model study on the mixing effect of injection method in UV/H2O2 process

  • Heekyong Oh;Pyonghwa Jang;Jinseok Hyung;Jayong Koo;SungKyu Maeng
    • Membrane and Water Treatment
    • /
    • v.14 no.3
    • /
    • pp.129-140
    • /
    • 2023
  • The appropriate injection of H2O2 is essential to produce hydroxyl radicals (OH·) by mixing H2O2 quickly and exposing the resulting H2O2 solution to UV irradiation. This study focused on evaluating mixing device of H2O2 as a design factor of UV/H2O2 AOP pilot plant using a surface water. The experimental investigation involved both experimental and model-based analyses to evaluate the mixing effect of different devices available for the H2O2 injection of a tubular hollow pipe, elliptical type of inline mixer, and nozzle-type injection mixer. Computational fluid dynamics analysis was employed to model and simulate the mixing devices. The results showed that the elliptical type of inline mixer showed the highest uniformity of 95%, followed by the nozzle mixer with 83%, and the hollow pipe with only 18%, after passing through each mixing device. These results indicated that the elliptical type of inline mixer was the most effective in mixing H2O2 in a bulk. Regarding the pressure drops between the inlet and outlet of pipe, the elliptical-type inline mixer exhibited the highest pressure drop of 15.8 kPa, which was unfavorable for operation. On the other hand, the nozzle mixer and hollow pipe showed similar pressure drops of 0.4 kPa and 0.3 kPa, respectively. Experimental study showed that the elliptical type of inline and nozzle-type injection mixers worked well for low concentration (less than 5mg/L) of H2O2 injection within 10% of the input value, indicating that both mixers were appropriate for required H2O2 concentration and mixing intensity of UV/ H2O2 AOP process. Additionally, the elliptical-type inline mixer proved to be more stable than the nozzle-type injection mixer when dealing with highly concentrated pollutants entering the UV/H2O2 AOP process. It is recommended to use a suitable mixing device to meet the desired range of H2O2 concentration in AOP process.

Effect of Coagulants and Separation Methods on Algal Removal in Water Treatment Process (정수처리에서 응집제 종류와 분리공정이 조류 제거에 미치는 영향)

  • Park, Hung-Suck;Lee, Sang-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.279-289
    • /
    • 2000
  • The objective of this study was to investigate the effect of coagulants and solid-liquid separation methods on algal removal in water treatment processes. Thus characterization of raw water quality in terms of turbidity. UV-254, $KMnO_4$ consumption, chlorophyll-a and correlation analysis of these parameters were conducted. In addition, the effect of commercial Al-based coagulants(Alum. PAC and PACS) on algal removal was studied by turbidity and organic removal, algal species removal, characteristic of pH drop and alkalinity consumption using laboratory jar tests. Organic components including UV-254, $KMnO_4$ consumption, chlorophyll-a in case of algal bloom were highly correlated with turbidity and the correlation coefficients of UV-254, $KMnO_4$ consumption, chlorophyll-a with turbidity were 0.775, 0674 and 0.623, respectively. In coagulation and sedimentation, the Al-based coagulants showed similar efficiency of organic and turbidity removal in low organic($KMnO_4$ consumption below 15mg/l) and low turbidity(below 30NTU). However, PAC and PACS showed better algal removal than alum in high organic concentration($KMnO_4$ consumption above 20mg/l) and high turbidity(above 100NTU) raw water conditions generated by high algal growth, which is considered to be due to the floc settleability. In comparison of sedimentation and flotation after chemical coagulation and flocculation, the removal efficiency of organic and turbidity were higher in case of alum dose with flotation than with sedimentation, while those were better in case or PAC and PACS with sedimentation than with flotation. Thus, Alum with flotation and PAC and PACS with sedimentation is recommended for efficient algal removal. The dominant phytoplankton in raw water were Microcystic and pediastrum simplex and the removal efficiency of algae with sedimentation using alum. PAC and PACS were 27%, 45% and 22% respectively, while those with DAF showed 100% removal of phytoplankton and zooplankton.

  • PDF

Residual Change of Deltamethrin in Stream Water after Spaying for Pest Control of Stream Levee (하천둔치에 방역용 Deltamethrin 살포 시 하천수 중 잔류변화)

  • Han, Ye-Hun;Park, Jae-Hun;Lim, Jong-Sung;Lee, Yong-Ju;Lee, Sung-Kyu;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.1
    • /
    • pp.78-83
    • /
    • 2013
  • BACKGROUND: This study was performed to investigate the change of deltamethrin residue after spraying for control of hygienic insects in bush of levee at Bansuk-dong stream (A) and Juk-dong ditch (B) in Yuseong, Daejeon. The drop concentrations and disappearance of deltamethrin residue in stream water were determined to evaluate the toxic effects of stream ecosystem. METHODS AND RESULTS: Water samples were collected at 7 points including 0, 5, 10, 20, 40, 70 and 100 m downstream from the deltamethrin spraying point. Water sample was partitioned into dichloromethane, and was determined with GC/${\mu}$-ECD. Limit of Quantitation of deltamethrin was 0.04 ${\mu}g/L$. Recoveries of deltamethrin at two fortification levels of 0.4 and 2.0 ${\mu}g/L$ were $91.57{\pm}3.13%$(n=3) and $94.40{\pm}4.59%$(n=3) in A stream, and $88.24{\pm}3.33%$(n=3) and $85.20{\pm}3.73%$(n=3) in B stream, respectively. Residue of A stream were from <0.04 ${\mu}g/L$ to 0.48 ${\mu}g/L$ and B stream were from 0.08 ${\mu}g/L$ to 14.95 ${\mu}g/L$ under practice application condition. And residues were from <0.04 ${\mu}g/L$ to 0.2 ${\mu}g/L$ in A stream treated deltamethrin with 1.0 mg level at the upper region. CONCLUSION(S): Practice application of deltamethrin for the pest control of waterside was not much shown toxic effect to ecosystem of stream.