• Title/Summary/Keyword: Water Drop

검색결과 904건 처리시간 0.022초

배플 플레이트를 갖는 열교환기의 열전달 및 압력강하에 관한 연구 (A study on heat transfer characteristics and pressure drop of heat transfer by baffle cut rate)

  • 배성우;최순호;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.172-177
    • /
    • 2005
  • The object of this experiment is comparing heat transfer performance and pressure drop characteristics by baffle cut rate, fluid velocity and heating temperature. Experiments were carried out in cross flow heat exchanger with water as a working fluid. In this experiment, baffle cut rate is 30%, 40%, 50%, velocity is 0.5m/s, 1.0m/s, 1.5m/s, and heating temperature is $30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$. An experimental device to measure the heat transfer coefficient was constructed. The experimental result were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux.

  • PDF

스태틱 믹서 개발 및 응용 (Development and Application of Static Mixer)

  • 양희천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-513
    • /
    • 2007
  • One of the most widely used static mixers is Sulzer type mixer. However the structure of the element is so complicated that the mixing efficiency is better than others, whereas the pressure drop is larger than the others. Therefore new elements are necessary to reduce the pressure drop and to minimize the decrease of the mixing efficiency compared with the Sulzer ones. The objectives of this study are to develop new static mixer and to perform the experimental investigation in order to evaluate the performance of the new one, and to investigate the applicability of the one in an inline coagulant mixing system for water treatment, The pressure drops of the new static mixer elements were about 4-12% lower than that of the Sulzer SMX one, and the mixing efficiency of the Sulzer SMX one was about 2-5% higher than that of the new ones. The inline coagulant mixing system with a new static mixer element performed significantly better than the traditional mechanical mixing system for turbidity removal.

연직낙차공 하류부 사석보호공 침하량 산정식에 관한 실험 연구 (An Experimental Study for the Empirical Equation to Quantify the Subsidence of Riprap Scour Protection at Downstream of Vertical Drop Structures)

  • 김창성;강준구;여홍구;여운광
    • 한국수자원학회논문집
    • /
    • 제43권5호
    • /
    • pp.433-443
    • /
    • 2010
  • 낙차공은 하천의 경사를 완화시키기 위해 설치하는 대표적 횡단구조물로써 국내 하천에서 쉽게 볼 수 있다. 낙차공물받이부(apron)는 낙차공 본체와 일체화된 구조물로 설치하는 것이 일반적이며 물받이부의 하류부에 바닥보호공을 설치하여 낙차공과 물받이를 보호하도록 설계된다. 이에 본 연구에서는 낙차공 물받이부에서의 세굴현상과 사석보호공을 설치함으로써 발생하는 침하량에 대한 실험을 수행하였다. 세굴은 낙차공에 유입되는 유량이 증가함에 따라 세굴심은 증가하지만 낙차공 하류부의 수심이 증가할수록 세굴심은 감소하는 것으로 나타났다. 또한 낙차공 물받이부 사석보호공을 포설두께에 따른침하량을 산정하여 세굴심을 제어하고 구조물의 안전을 확보할 수 있는 가능성을 확인하였으며 최종적으로 필터가 없는 사석보호공의 무차원 침하량 산정식을 제안하였다.

다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구 (An analytical study on the thermal performance of multi-tube CO2 water heater)

  • 장근선;최연성;김영재
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.23-30
    • /
    • 2016
  • 본 연구에서는 길이 4.5 m와 7.5 m의 다중관 $CO_2$ 급탕 열교환기의 열전달 및 압력강하 특성을 ${\epsilon}-NTU$ 방법을 사용하여 해석하고 결과를 기존의 실험 데이터와 비교하였다. 급탕 열교환기는 쉘측에 물이 흐르고 8개로 구성된 내부 튜브에 $CO_2$를 흐르게 하였으며 열전달 효율을 최대화하기 위하여 대향류로 설계하였다. 각 노드에 대한 물과 $CO_2$ 냉매의 유동에 대한 에너지 평형 방정식은 단면분할법을 이용하여 해석하였다. 열전달율 계산값은 실험값과 ${\pm}5%$ 범위 내에서 잘 일치하였다. 반면에 물의 출구온도는 물 유량이 증가함에 따라 거의 선형적으로 감소하며 계산값과 실험값은 ${\pm}3%$ 내에서 일치하였다. 결과에서 열전달율은 4.5 m와 7.5 m 급탕 열교환기 모두 물 유량 또는 $CO_2$ 입구온도가 증가함에 따라 거의 선형적으로 증가하였으며, 반면에 물 유량이 증가함에 따라 물의 출구온도는 선형적으로 감소하였다. $CO_2$ 압력강하 계산값과 실험값은 $CO_2$가 고유량일 때 5 % 내에서 잘 일치한 반면에 $CO_2$가 저유량일 때 실험값이 약 20 % 높게 나타났다.

강제 환기식 육계사 다중 입기 슬롯에서의 입기류 도달거리 분석 (Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House)

  • 권경석;하태환;이인복;홍세운;서일환
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.55-65
    • /
    • 2012
  • In the winter season, when the ventilation system is operating, the fresh cold air from the slot-type openings of broiler house which directly reached the animal zone can cause various problems such as thermal stress, decreasing of feed and water consumption, occurrence of respiratory disease, and etc. Therefore it is very important to control the trajectory of aero-flow from the slot openings to induce an efficient thermal heat change. Jet-drop distance model was proposed to predict and control the jet-trajectory. However their study was restricted due to the small scaled model and difficulties of measuring the Jet-drop distance. In this study, CFD was applied to analyze qualitatively and quantitatively the jet-drop distance in a real broiler house. The various variables were considered such as installed slot-angle, designed ventilation rate, and the outdoor ambient temperature. From the present study, two linear-regression models using the Jet-drop factor and corrected Archimedes number, and their R-squared values 0.744 and 0.736, respectively, were used. From this study, the applicability of CFD on the analysis of Jet-drop distance model was confirmed.

판각형 열교환기 내의 R-22 증발 압력강하 특성에 관한 실험적 연구

  • 서무교;박재홍;김영수
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.930-938
    • /
    • 2001
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by adding three plates having a corrugated channel of a chevron angle of $45^{\circ}$. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop increases with the vapor quality for both types of P&SHE. At a higher mass flux, the pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower.

  • PDF

헬기에 의한 지상 물투하 형태 및 범위 실험 (Study on Ground Water Drop Pattern and Coverage Level by Helicopter)

  • 배택훈;이시영;손정훈
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.54-61
    • /
    • 2013
  • 항공기에 의한 산불공중진화는 지상진화 보다 진화의 효과성이 좋다. 따라서 공중진화는 산불의 대형화를 방지하는데 중요하다. 미국에서는 고정익항공기 및 회전익항공기(헬리콥터)가 합동으로 공중진화를 하나 우리나라는 회전익항공기만을 이용하고 있다. 따라서 헬리콥터에 의한 공중진화의 효과성에 대한 연구가 필요하다. 공중진화의 효과성은 투하되는 물의 분포형태와 범위에 따라서 결정된다. 따라서 본 연구는 산림청에서 운용하는 S-64E, Ka-32T, AS350B2의 3개 기종으로 물투하 실험을 실시하여 유효 분포형태와 범위를 도출하였다. 이 연구 결과로 조종사들이 공중진화의 효과성을 증대시키는데 기여하고자 한다.

바이패스용 3-Way 밸브를 장착한 온수 난방시스템의 압력 및 유량 특성 평가 (Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass)

  • 허전;이석종;성재용;이명호;윤재동
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.269-274
    • /
    • 2007
  • A 3-way valve has been applied to a distributor in a hot-water heating system and the performance of the system was evaluated in view of the variations of pressure drop and flow rate. The 3-way valve has been designed to bypass overplus hot-water when a control valve is closed. Note that the flow goes through heating pipeline in normal operation. In the present study, the measured pressure drops in each part of the flow paths show that the contribution to the total pressure drop is in the order of the supply header with control valves, piping system of each room and return header of the distributor, even though the amount of it is different according to the flow paths. As a result of performance test by sequential closing of the control valves, the variations of pressure drop and flow rate in the distributor with 3-way valves is much lower than those with previous 2-way valves, which prevent noises induced by pressure fluctuations.

이유체 선회분사 노즐의 액적크기에 관한 실험적 연구 (An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle)

  • 오제하;김원태;강신재;노병준
    • 한국분무공학회지
    • /
    • 제1권1호
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

광센서를 이용한 실시간 중환자 요량감시 장치 (Real-time urine monitoring system for intensive care patient using optical sensor)

  • 김종명;이진영;홍주현;임승운;차은종;이태수
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.81-85
    • /
    • 2008
  • This paper addressed real-time urine monitoring device for intensive care patients. The device was developed to detect and count each urine drop using optical sensor and calculate the current urine output volume and its hourly rate. In experiment, the water volume scale of drainage bottle was observed and compared with the count of the device so that the volume of each drop was found to vary with the dropping rate per minute. From this measurement, the relationship equation was derived to estimate the total water volume from the drop rate (correlation coefficient : r= 0.99). The developed device could be applied to count patient's urine drop successfully. Therefore, this device can be used to monitor intensive care patient's urine status in real-time.