• Title/Summary/Keyword: Water Drop

Search Result 910, Processing Time 0.026 seconds

Storm Surge Caused by the Typhoon in Kwangyang Port (광양항에서의 폭풍해일 검토)

  • Kim, Hyeon-Seong;Im, Hyo-Hyuc;Han, Dong-Hoon;Kim, Pyeong-Joong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.205-206
    • /
    • 2006
  • The surges caused by the typhoon of Korea are analysed in Kwangyang Bay. The deviations of the high water level were $74{\sim}185cm$ and the maximum deviations of the water level (maximum surges) were $151{\sim}240cm$ in Kwangyang Bay during the typhoon. The major parameters of the maximum deviations of the water level are as follows : Analysis shows that the pressure drop increased the sea level by $43{\sim}59cm$, the flood of the Sumjin River by $4{\sim}5cm$ and the external surge propagation and wind setup by $97{\sim}192cm$.

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

Non-dimensional analysis of cylindrical objects freely dropped into water in two dimensions (2D)

  • Zhen, Yi;Yu, Xiaochuan;Meng, Haozhan;Li, Linxiong
    • Ocean Systems Engineering
    • /
    • v.10 no.3
    • /
    • pp.267-287
    • /
    • 2020
  • The dropped objects are identified as one of the top ten causes of fatalities and serious injuries in the oil and gas industry. It is of importance to understand dynamics of dropped objects under water to accurately predict the motion of dropped objects and protect the underwater structures and facilities from being damaged. In this paper, we study non-dimensionalization of two-dimensional (2D) theory for dropped cylindrical objects. Non-dimensionalization helps to reduce the number of free parameters, identify the relative size of effects of force and moments, and gain a deeper insight of the essential nature of dynamics of dropped cylindrical objects under water. The resulting simulations of dimensionless trajectory confirms that drop angle, trailing edge and drag coefficient have the significant effects on dynamics of trajectories and landing location of dropped cylindrical objects under water.

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

A Study on Scale Busting and Preventing Effect of Coating Ceramic Ball (코팅 세라믹볼의 방청효과에 관한 연구)

  • 하윤식;김학용;김수진;백우현
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1117-1123
    • /
    • 2002
  • Coating ceramic balls activate water molecular in water as radiate far-infrared radiation of high efficiency, and then prevent formation of scale and corrosion of pipe. Therefore, but only keep away drop of heat exchange efficiency of boiler, not also remove formed scale. As a result, pipe of boiler has clean and has form thin protection film in inner of pipe. Also, the water treated by rust preventing system using the ceramic balls, that is harmless, tasteless, odorless, and non-toxicity in the human body, and it can use drinking water. This rust preventing system can save energy and protect environment.

Characteristics of Drag Reduction Additives in the Application of District Cooling System (지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구)

  • 윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF

Prediction and Verification of Water-entry Traces Size of Small Falling Objects into the Sea (해상 소형 낙하물 입수흔적의 크기 예측 및 검증)

  • Min, Anki;Hwang, Tae-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.146-153
    • /
    • 2015
  • An unmanned aerial photography method by using an unmanned helicopter is useful method for measuring of the water-entry traces of small falling objects into the sea. Pixel sizes on the aerial photograph may be too large due to a limit of camcorder resolution and a wide shooting area. If the pixel size is too large, identification of water-entry trace is impossible. Thus an accurate prediction of water-entry trace size is required. The traces of water-entry could be classified into three types such as splash, water column, and bubble. Diameters of each trace are predicted by water-entry impact pressure theories, cavity theories, and trial test results. The results are verified by drop tests using an unmanned helicopter at two water-entry speeds. As a result, prediction and test results showed sufficient similarity to evaluate the identifiability of water-entry trace.

Water transport through hydrophobic micro/nanoporous filtration membranes on different scales

  • Mian, Wang;Yongbin, Zhang
    • Membrane and Water Treatment
    • /
    • v.13 no.6
    • /
    • pp.313-320
    • /
    • 2022
  • Theoretical calculation results are presented for the enhancement of the water mass flow rate through the hydrophobic micro/nano pores in the membrane respectively on the micrometer and nanometer scales. The water-pore wall interfacial slippage is considered. When the pore diameter is critically low (less than 1.82nm), the water flow in the nanopore is non-continuum and described by the nanoscale flow equation; Otherwise, the water flow is essentially multiscale consisting of both the adsorbed boundary layer flow and the intermediate continuum water flow, and it is described by the multiscale flow equation. For no wall slippage, the calculated water flow rate through the pore is very close to the classical hydrodynamic theory calculation if the pore diameter (d) is larger than 1.0nm, however it is considerably smaller than the conventional calculation if d is less than 1.0nm because of the non-continuum effect of the water film. When the driving power loss on the pore is larger than the critical value, the wall slippage occurs, and it results in the different scales of the enhancement of the water flow rate through the pore which are strongly dependent on both the pore diameter and the driving power loss on the pore. Both the pressure drop and the critical power loss on the pore for starting the wall slippage are also strongly dependent on the pore diameter.

Reactivities of Di-iso-butylnitrosoamine by Anodic Film Formed on Metals (산화피막전극을 이용한 디이소부틸니트로소아민의 전극반응)

  • Hwang Kum-Sho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.2
    • /
    • pp.94-102
    • /
    • 1981
  • To investigate the characteristics of anodic film formed on metals and the reactivities of organic inhibitor Di-iso-butylnitrosoamine (DBNA) in sea water. the cathodic reactions of anodic film formed on metals were carried out by using the potential drop method and galvanostatic method at $25^{\circ}C$. The investigated results are as follows: The anodic films formed on aluminum and zinc in 60mM $DBNA+9\%_{\circ}$ sea water did not show-changes of potential drop. However, those formed on lead and copper were reasonable electrodes. It was concluded that cathodic reactivities of proton through the anodic film in aqueous solution were constant without regard to the kinds of metals used with anodic film electrode at operated current density ranges, because the values of transition time obtained in 0.5M sodium chloride solution and $9\%_{\circ}$ sea water nearly coincided. The values of transition time of the first step by the galvanostatic method were obtained from 0.22 to 1.40 sec ranges far less than one minute. Therefore, it suggested that cathodic reactions of proton through the anodic film were mainly controlled by diffusion/adsorption process. The differences of between $\tau_{1}/4$ in $9\%_{\circ}$ sea water and $\tau_{1}/4$ in 60mM $DBNA+9\%_{\circ}$ sea water, and between $E_{1}/4$ in sea water and $E_{1}/4$ in 60mM $DBNA+9\%_{\circ}$ sea water at the constant current density with $1.9\times10^{-4}\sim5.0{\times}10^{-6}\;amp/cm^2$ were 0.06 sec and 0.53 v. respectively and cathodic reactions of DBNA on the anodic film electrodes were chiefly controlled by adsorption/diffusion process. The reason that adsorption quantities of proton on anodic film formed on aluminum and zinc in aqueous solutions were much more than those on lead and copper, seems to lie due mostly to the number of porosity produced on anodic film used.

  • PDF

River Water Temperature Variations at Upstream of Daecheong Lake During Rainfall Events and Development of Prediction Models (대청호 상류 하천에서 강우시 하천 수온 변동 특성 및 예측 모형 개발)

  • Chung, Se-Woong;Oh, Jung-Kuk
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.1 s.162
    • /
    • pp.79-88
    • /
    • 2006
  • An accurate prediction of inflow water temperature is essentially required for real-time simulation and analysis of rainfall-induced turbidity 烈os in a reservoir. In this study, water temperature data were collected at every hour during the flood season of 2004 at the upstream of Daecheong Reservoir to justify its characteristics during rainfall event and model development. A significant drop of river water temperature by 5 to $10^{\circ}C$ was observed during rainfall events, and resulted in the development of density flow regimes in the reservoir by elevating the inflow density by 1.2 to 2.6 kg/$m^3$ Two types of statistical river water temperature models, a logistic model(DLG) and regression models(DMR-1, DMR-2, DMR-3) were developed using the field data. All models are shown to reasonably replicate the effect of rainfall events on the water temperature drop, but the regression models that include average daily air temperature, dew point temperature, and river flow as independent variables showed better predictive performance than DLG model that uses a logistic function to determine the air to water relation.