• Title/Summary/Keyword: Water Cleaning

Search Result 694, Processing Time 0.027 seconds

Quality Control of Observed Temperature Time Series from the Korea Ocean Research Stations: Preliminary Application of Ocean Observation Initiative's Approach and Its Limitation (해양과학기지 시계열 관측 자료 품질관리 시스템 구축: 국제 관측자료 품질관리 방안 수온 관측 자료 시범적용과 문제점)

  • Min, Yongchim;Jeong, Jin-Yong;Jang, Chan Joo;Lee, Jaeik;Jeong, Jongmin;Min, In-Ki;Shim, Jae-Seol;Kim, Yong Sun
    • Ocean and Polar Research
    • /
    • v.42 no.3
    • /
    • pp.195-210
    • /
    • 2020
  • The observed time series from the Korea Ocean Research Stations (KORS) in the Yellow and East China Seas (YECS) have various sources of noise, including bio-fouling on the underwater sensors, intermittent depletion of power, cable leakage, and interference between the sensors' signals. Besides these technical issues, intricate waves associated with background tidal currents tend to result in substantial oscillations in oceanic time series. Such technical and environmental issues require a regionally optimized automatic quality control (QC) procedure. Before the achievement of this ultimate goal, we examined the approach of the Ocean Observatories Initiative (OOI)'s standard QC to investigate whether this procedure is pertinent to the KORS. The OOI QC consists of three categorized tests of global/local range of data, temporal variation including spike and gradient, and sensor-related issues associated with its stuck and drift. These OOI QC algorithms have been applied to the water temperature time series from the Ieodo station, one of the KORS. Obvious outliers are flagged successfully by the global/local range checks and the spike check. Both stuck and drift checks barely detected sensor-related errors, owing to frequent sensor cleaning and maintenance. The gradient check, however, fails to flag the remained outliers that tend to stick together closely, as well as often tend to mark probably good data as wrong data, especially data characterized by considerable fluctuations near the thermocline. These results suggest that the gradient check might not be relevant to observations involving considerable natural fluctuations as well as technical issues. Our study highlights the necessity of a new algorithm such as a standard deviation-based outlier check using multiple moving windows to replace the gradient check and an additional algorithm of an inter-consistency check with a related variable to build a standard QC procedure for the KORS.

A Study of Oral Health Knowledge and Status of the Elderly in Ulju-gun (울주군 일부지역 노인의 주관적 구강건강인지 및 수준에 관한 조사)

  • Lee, Jung-Hwa;Seong, Mi-Gyung;Kang, Hyun-Kyung;Cho, Gab-Suk
    • Journal of dental hygiene science
    • /
    • v.7 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • The purpose of this research was to find out their perception of the dental hygiene and level of its knowledge by estimating status of senior adults' dental health management. First, questionnaires were distributed to the 256 target senior adults aged more than 60, who were going to school for senior adults located in Ulju Country and the survey was conducted by interview directly. The results were as follows; 1. As for tooth brushing method, scrubbing method was used in male and rolling method was used in female and the survey results statistically revealed that rolling method was the most used in aged from 60 to 70(68.1%) and scrubbing method was the most used in aged more than 70(80.4%)[p < 0.001]. 2. As for reason of visiting dental clinic, female respondents accounting for the highest said they visited dental clinic when they feel a pain in the teeth and as for frequence of dental clinic, male respondents visited dental clinic for a once per a year. there was no difference statistically according to age(47.9%). 3. As for the perception of the necessity of dental prosthetic treatment, there was higher positive response in the female than male, in the lower aged groups than higher aged group[p<0.05]. 4. As for the question of whether to use of denture or not now, the survey results was statistically that the higher aged group and male groups were higher used dentures [p < 0.001]. 5. As for maintenance of denture, female respondents said the highest that they keep it in cold water after cleaning(95.5%), there was no difference statistically according to age and educational background [p < 0.001].

  • PDF

MORPHOLOGIC ANALYSIS OF C-SHAPED ROOT USING 3-D RECONSTRUCTION (3차원 재구성법에 의한 C-shaped root의 형태분석)

  • Jung, Eun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.421-431
    • /
    • 2002
  • C-shaped canal configuration is very difficult to treat because that clues about preoperative canal anatomy cannot be ascertained from clinical crown morphology and limited information can be derived from radiographic examination. This study was done to get more informations about the root and canal configuration of C-shape root by 3-dimensionally reconstructing for the purpose of enhancing success rate of endodontic treatment. 30 mandibular molars with C-shaped root were selected. Six photo images from occlusal, apical, mesial, distal, buccal, lingual directions and radiographic view were taken as preoperative ones to compare them with 3-D image. After crown reduction to the level of 1-2mm over pulpal floor was performed, teeth were stored in 5.25% sodium hypochlorite solution for the removal of pulp tissue and debris. They were cleaned under running water, allowed to bench dry and embedded in a self-curing resin. This resin block was serially ground with a microtome (Accutom-50, Struers, Denmark) and the image of each level was recorded by digital camera (FinePix S1-pro, Fuji Co., Japan). The thickness of each section was 0.25mm. Photographs of serial sections through all root canal were digitized using Adobe Photoshop 5.0 and then minimum thickness of open and closed sites were measured (open site is the surface containing occluso-apical groove closed site is oppsite). After dizitization using 3-D Doctor (Able software Corp, USA). 3D reconstruction of the outer surface of tooth and the inner surface of pulp space was made. Canal classsification of C-shaped roots was performed from this 3-D reconstructed image. The results were as follows : 1. Most C-shape rooted teeth showed lingual groove (28/30). 2 According to Vertuccis' calssification, type I, II, III, IV, VII were observed. but also new canal types suck as 2-3-2, 1-2-3-2. 2-3-2-1, 2-3-2-3 were shown. 3 There was little difference in minimum thickness on coronal and apical portions, but open site were thinner than closed site on mid portion. Conclusively, 3D reconstruction method could make the exact configurations of C-shape root possible to be visualized and analyzed from multi-directions. Data from minimum thickness recommend cleaning and shaping be more carefully done on dangerous mid portion.

Airborne Bacteria Concentration and Species Identification in Residential Living Spaces (주택내 주거공간에 따른 부유세균 농도 분포 및 종 동정 연구)

  • Kim, Sung-Yeon;Jheong, Weonhwa;Hwang, Eun-Seol;Kim, Ji-Hye;Jung, Joon-Sig;Lee, Jae-won;Chung, Hyen-Mi;Kwon, Myunghee
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.6
    • /
    • pp.438-449
    • /
    • 2016
  • Objectives: Exposure to airborne bacteria is associated with adverse health effects such as respiratory and infectious diseases. This study evaluated airborne bacterial concentrations in the living rooms, kitchens, and toilets of 30 homes. Methods: Bacteria were sampled with an MAS100 impactor in three spaces in the subject homes between April 2014 and February 2015. Bacteria were grown on TSA plates for 48 hours at $35^{\circ}C$. The bacterial strains were isolated and amplified by polymerase chain reaction. Results: The most culturable bacteria were found in toilets ($624.0CFU/m^3$, GM: $417.3CFU/m^3$), followed by in the kitchen ($503.8CFU/m^3$, GM: $324.9CFU/m^3$). The dominant genera identified were: Staphylococcus sp.(19%), Micrococcus sp.(16%), and Bacillus sp.(11%) in the indoor air and Bacillus sp. (30%) in the outdoor air. Gram-positive bacteria comprised more than half of all colonies. Conclusion: In this study, culturable bacteria concentrations were higher than those reported in other spaces. Therefore, it is important to control relative humidity and remove moisture to prevent bacteria from multiplying. Additionally, the dominant species in indoor air were Staphylococcus sp. and Micrococcus sp. These are found on the human skin, mucous membranes, and hair, so human activity can affect bacterial distribution. Therefore, cleaning and controlling moisture are important for reducing indoor bacterial concentrations.

Biological control of mushroom mites using predatory mite Stratiolaelaps scimitus in button mushroom (Agaricus bisporus) cultivation (양송이에서 포식성 스키미투스응애 (Stratiolaelaps scimitus)를 이용한 버섯응애류의 생물적 방제 효과)

  • Yoon, Jungbeom;Kim, Hyeonghwan;Kim, Donghwan;Yang, Changyeol;Seo, Mihye
    • Journal of Mushroom
    • /
    • v.15 no.4
    • /
    • pp.254-258
    • /
    • 2017
  • Mushroom mites have recently caused severe damage to sawdust beds, mushroom mycelia, and fruiting bodies; therefore, they have reduced the production of the button mushroom, Agaricus bisporus, in greenhouses. There are currently no registered pesticides for mushroom mites. It is necessary to selectively control mushroom flies and mites without affecting the growth of the mushroom. We examined biological control of mushroom mites using predatory mite Stratiolaelaps scimitus in button mushroom cultivation. As a result, a three times treatment (1 treatment after water cleaning, 1 treatment after fungus inoculation, and 1 treatment before or after casing) was most effective at controlling mushroom mites, with 3.000 predatory mites (3 bottles) scattered evenly over $165-230m^2$ every 1-2 m. Predatory mite Stratiolaelaps scimitus could control mushroom flies and mites at the same time and could be used at any time during cultivation.

Electrical Characteristic of IGZO Oxide TFTs with 3 Layer Gate Insulator

  • Lim, Sang Chul;Koo, Jae Bon;Park, Chan Woo;Jung, Soon-Won;Na, Bock Soon;Lee, Sang Seok;Cho, Kyoung Ik;Chu, Hye Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.344-344
    • /
    • 2014
  • Transparent amorphous oxide semiconductors such as a In-Ga-Zn-O (a-IGZO) have advantages for large area electronic devices; e.g., uniform deposition at a large area, optical transparency, a smooth surface, and large electron mobility >10 cm2/Vs, which is more than an order of magnitude larger than that of hydrogen amorphous silicon (a-Si;H).1) Thin film transistors (TFTs) that employ amorphous oxide semiconductors such as ZnO, In-Ga-Zn-O, or Hf-In-Zn-O (HIZO) are currently subject of intensive study owing to their high potential for application in flat panel displays. The device fabrication process involves a series of thin film deposition and photolithographic patterning steps. In order to minimize contamination, the substrates usually undergo a cleaning procedure using deionized water, before and after the growth of thin films by sputtering methods. The devices structure were fabricated top-contact gate TFTs using the a-IGZO films on the plastic substrates. The channel width and length were 80 and 20 um, respectively. The source and drain electrode regions were defined by photolithography and wet etching process. The electrodes consisting of Ti(15 nm)/Al(120 nm)/Ti(15nm) trilayers were deposited by direct current sputtering. The 30 nm thickness active IGZO layer deposited by rf magnetron sputtering at room temperature. The deposition condition is as follows: a rf power 200 W, a pressure of 5 mtorr, 10% of oxygen [O2/(O2+Ar)=0.1], and room temperature. A 9-nm-thick Al2O3 layer was formed as a first, third gate insulator by ALD deposition. A 290-nm-thick SS6908 organic dielectrics formed as second gate insulator by spin-coating. The schematic structure of the IGZO TFT is top gate contact geometry device structure for typical TFTs fabricated in this study. Drain current (IDS) versus drain-source voltage (VDS) output characteristics curve of a IGZO TFTs fabricated using the 3-layer gate insulator on a plastic substrate and log(IDS)-gate voltage (VG) characteristics for typical IGZO TFTs. The TFTs device has a channel width (W) of $80{\mu}m$ and a channel length (L) of $20{\mu}m$. The IDS-VDS curves showed well-defined transistor characteristics with saturation effects at VG>-10 V and VDS>-20 V for the inkjet printing IGZO device. The carrier charge mobility was determined to be 15.18 cm^2 V-1s-1 with FET threshold voltage of -3 V and on/off current ratio 10^9.

  • PDF

A study on the flushing characteristics in Geunso bay using hydro-hypsographic analysis (Hydro-hypsographic 분석을 이용한 근소만 해수 교환 특성 연구)

  • Choi, Jong-Kuk;Ryu, Joo-Hyung;Woo, Han-Jun;Eom, Jin-Ah
    • Journal of Wetlands Research
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2011
  • Seawater circulations between a bay and the open sea play an important role to make the ecosystem healthy, providing nutrient and oxygen to the benthic environments and cleaning up pollutions. The health of the benthic environment in a bay is closely related to the flushing characteristics of seawater. In this study, to estimate the seawater distribution and circulation characteristics of benthic environment in the Geunso bay, we calculated the hydraulic turn-over time by a hydro-hypsographic analysis. Digital elevation model (DEM) which was generated using waterline method based upon remotely sensed data and water depth of the subtidal zone estimated by echo-sounding survey was applied to the hydro-hypsograhic analysis through a geographic information system (GIS) spatial analysis. The results showed that 95% of the total area of the bay was tidal flat and the hydraulic turn-over time was 1.03 tidal cycle, which indicated that the flushing characteristics of the Geunso bay was very good. Geunso bay was revealed to occupy relatively wide area of benthic environment and to have relatively big tidal range over other domestic and foreign coastal environment, therefore it could have a better seawater circulation characteristics. This result can be effectively applied as fundamental information to establish the system for a quantitative estimate of health of coastal environment in the west coast of Korea and manage the ecosystem in benthic environments.

A Study on the Mill Scale Pretreatment and Magnetite Production for Phosphate Adsorption (인 흡착을 위한 Mill Scale 전처리 및 Magnetite 제조 연구)

  • Chun, Hyuncheol;Choi, Younggyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.246-252
    • /
    • 2015
  • In steel factory, hot roller cleaning process produces a lot of iron oxide particles called as mill scale. Major components of these particles are wustite (FeO), magnetite ($Fe_3O_4$), and hematite ($Fe_2O_3$). In this study, we tried to produce pure magnetite from the mill scale because of the largest phosphate adsorption capacity of the magnetite. The mill scale was treated with acid (HCl+$H_2O_2$), base (NaOH), and acid-base ($H_2SO_4$+NaOH). Batch adsorption tests showed the acid and/or base treatment could increase the phosphate adsorption capacity of the iron oxides from 0.28 to over 3.11 mgP/g. Magnetite, which could be obtained by acid and base treatment of the mill scale, showed the best adsorption capacity. From the kinetic analysis, both Freundlich and Langmuir isotherm well described the phosphate adsorption behavior of the magnetite. In Langmuir model, maximum phosphate adsorption capacity was found to be 5.1 mgP/g at $20^{\circ}C$.

Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion (혐기성 소화의 후처리로서 분리막의 여과특성 연구)

  • Choo, Kwang-Ho;Lee, Chung-Hak;Pek, Un-Hwa;Koh, Ui-Chan;Kim, Sang-Won;Koh, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.730-738
    • /
    • 1992
  • Filtration characteristics according to membrane materials were studied In the ultrafiltration of anaerobic digestion broth as a post treatment method. A series of resistances for different membranes were quantitatively assessed on the basis of the resistance-in-series model. Flux behavior observed with the digestion broth was irrelevant to initial water permeabilities of each membrane. The fluoro polymer membrane showed the most significant improvement of flux with increase of cross-flow velocity, which suggests that the cake layer formed on this membrane is more weakly attached to the membrane surface than those on the other membranes. Flux reduction during longtime running was attrib-used to the polarization layer resistance ($R_p$) as well as the fouling layer resistance($R_f$). Continuous increase of $R_p$ may reflect the variation in the characteristics of cake layers, which could result from size, shape, and structure changes due to lysis and growth of biomass. Hydrophilic cellulosic membrane had a much lower fouling tendency than hydrophobic polysulfone membrane. The depressurization method induced a small increase in flux of $5-10L/m^2/h$. During washing and cleaning, filtrability of each membrane was rapidly recovered within 15 minutes until a stationary value was reached.

  • PDF

Prevention of P-i Interface Contamination Using In-situ Plasma Process in Single-chamber VHF-PECVD Process for a-Si:H Solar Cells

  • Han, Seung-Hee;Jeon, Jun-Hong;Choi, Jin-Young;Park, Won-Woong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.204-205
    • /
    • 2011
  • In thin film silicon solar cells, p-i-n structure is adopted instead of p/n junction structure as in wafer-based Si solar cells. PECVD is a most widely used thin film deposition process for a-Si:H or ${\mu}c$-Si:H solar cells. For best performance of thin film silicon solar cell, the dopant profiles at p/i and i/n interfaces need to be as sharp as possible. The sharpness of dopant profiles can easily achieved when using multi-chamber PECVD equipment, in which each layer is deposited in separate chamber. However, in a single-chamber PECVD system, doped and intrinsic layers are deposited in one plasma chamber, which inevitably impedes sharp dopant profiles at the interfaces due to the contamination from previous deposition process. The cross-contamination between layers is a serious drawback of a single-chamber PECVD system in spite of the advantage of lower initial investment cost for the equipment. In order to resolve the cross-contamination problem in single-chamber PECVD systems, flushing method of the chamber with NH3 gas or water vapor after doped layer deposition process has been used. In this study, a new plasma process to solve the cross-contamination problem in a single-chamber PECVD system was suggested. A single-chamber VHF-PECVD system was used for superstrate type p-i-n a-Si:H solar cell manufacturing on Asahi-type U FTO glass. A 80 MHz and 20 watts of pulsed RF power was applied to the parallel plate RF cathode at the frequency of 10 kHz and 80% duty ratio. A mixture gas of Ar, H2 and SiH4 was used for i-layer deposition and the deposition pressure was 0.4 Torr. For p and n layer deposition, B2H6 and PH3 was used as doping gas, respectively. The deposition temperature was $250^{\circ}C$ and the total p-i-n layer thickness was about $3500{\AA}$. In order to remove the deposited B inside of the vacuum chamber during p-layer deposition, a high pulsed RF power of about 80 W was applied right after p-layer deposition without SiH4 gas, which is followed by i-layer and n-layer deposition. Finally, Ag was deposited as top electrode. The best initial solar cell efficiency of 9.5 % for test cell area of 0.2 $cm^2$ could be achieved by applying the in-situ plasma cleaning method. The dependence on RF power and treatment time was investigated along with the SIMS analysis of the p-i interface for boron profiles.

  • PDF