• Title/Summary/Keyword: Watch

Search Result 992, Processing Time 0.024 seconds

Healthcare IoT: DNA Watch (헬스케어 IoT: DNA 시계)

  • Kim, Jeong Su;Lee, Moon Ho;Park, Daechul
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.66-75
    • /
    • 2018
  • This paper is the second part of the January 2018 issue of the Korean Society for Engineering Education, The "Equilibrium and Unbalance Analysis of Taegeuk Pattern DNA Matrix Codes," and is an extension of the paper published in the IoT Section of the 2017 Summer Conference in Jeju. In this paper, we have reviewed the history of what is life, and 5G Mobile communication: with IoT followed by recent research on influenza RNA gene mutation and DNA mutation variants, and the insights of Watson and Crick. Inspired by a single Franklin DNA X-ray diffraction photograph, they received the Nobel Prize for the Nature publication of DNA that has three patterns and regular repeatability. Professor MoonHo Lee has solved the three patterns in Diagonal, Left to Right, and Vertical matrices in a 2x2 matrix[CU; AG] and A = T = U = 30% C = G = 20%. We also proposed DNA Watch. This is the Healthcare IoT, which is seen by the DNA Watch on the wrist, the type of Tai Chi pattern of the body, and is immediately connected to the smartphone and delivered to the doctor.

Investigation of Operation and Improvement for Heat Watch Warning System to Provide Health-Weather Information (보건기상정보 제공을 위한 폭염특보 운영현황 및 개선방안 조사)

  • Hwang, Mi-Kyoung;Kang, Yoon-Hee;Kim, Sungmin;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.277-285
    • /
    • 2019
  • Heat watch warning systems are operating in Korea and several other countries (China, the United Kingdom, France, the United States, Germany, Australia, and Japan). The heat wave indices used in this system are the heat index, perceived temperature, the wet bulb globe temperature, and the daily maximum temperature. To improve the heat wave advisory and warning system, some suggestions have been made. The meteorological-health index (i.e., indirect index), has especially been proposed in previous studies. This information should be provided not only to vulnerable groups (seniors, infants, and children), but also to outdoor workers who may be particularly exposed to heat waves. In addition, to have sufficient preemptive response times, the need for an extension of the heat watch warning period was suggested. Finally, the subdivision of administrative units and risk stages was proposed.

A Method for Detecting Movement and Posture During Sleep Using an Acceleration Sensor of a Wearable Device (웨어러블 단말의 가속도 센서를 이용한 수면 중 움직임 및 자세를 감지하는 방법)

  • Jeon, YeongJun;Kim, SangHyeok;Kang, SoonJu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • The number of patients with many complications grows with the increase of aging population. As the elders and severely ill patients spend most of their time in bed, it leads to Pressure Injuries (PI) such as bedsores. Unfortunately, there is no method to automatically detect changes in patient's posture which leads to the need for a caregiver every set of times when the patient needs to be moved. Many studies are conducted to solve this inefficient problem. Yet, these studies require costly devices or use methods that disturb patient's sleeping environment. Those methods are mostly hard to implement in practice due to these reasons. We propose a method to detect posture using a three-axis acceleration sensor from the wrist band. We developed a wearable watch that measures sleep-related data. We analyzed 40 people's sleep data with a wearable module and watch to measure their postures such as supine, left-side, and right-side. Then, we compared the classified posture from the watch with the wearable module and achieved 90% accuracy. Therefore, we concluded that only by using the wearable watch, we can detect the sleeping position without any new equipment or system to diagnose the patients without discomfort during their daily lives.

A Study on the Relationship between Ultraviolet Rays and Skin Color Using a Photoplethysmography Sensor

  • So-Yae Hur;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.1
    • /
    • pp.363-369
    • /
    • 2023
  • In this study, to check the function of managing the severity of ultraviolet rays with a smart watch, a popular health care IT device, It was tested whether measuring heart rate using a PPG(Photoplethysmography) sensor representatively used in a smart watch could tell skin changes caused by ultraviolet rays. Through this experiment, we examined the possibility that the skin color tanned by ultraviolet rays can be determined only by the heart rate measurement function of the PPG sensor. In addition, the possibility of expanding the heart rate measurement function of the PPG sensor to the use of skin condition management was considered. we used an Arduino-based reflective PPG sensor to measure changes in heart rate by selecting body sites with high and low UV rays exposure. A significant value was derived through tests considering factors such as gender, UV exposure, and age. As a result, the study identified the possibility of adding ultraviolet rays and skincare items to future smart watch healthcare items and the possibility of expanding skin measurement methods. It is also possible to suggest the direction of future research.

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part II: Improvement of Criteria (고온건강경보시스템 기준 설정에 관한 연구 ( II ) - 설정 기준 개선 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Kim, Eun-Byul;Song, Jeong-Hui
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.781-796
    • /
    • 2009
  • The current standard level of Heat Health Watch Warning System consider both daily maximum temperature and daily maximum heat index(HI), but current standard could not consider daily maximum HI due to the difficulties in forecasting when we consider both daily maximum temperature and daily maximum HI and no considering HI because relative humidity could not observed for some regions. So, Newly established standard level of Heat Health Watch Warning System is based on daily maximum temperature exceeding $30^{\circ}C$ for two consecutive days or daily minimum temperature exceeding $25^{\circ}C$ and daily maximum temperature exceeding $30^{\circ}C$. These days are called "extreme heat days". On extreme heat days, the standard of extreme heat advisory is based on daily maximum temperature among exceeding $32.7^{\circ}C$ and not exceeding $34.8^{\circ}C$, and extreme heat warning is based on daily maximum temperature exceeding $34.8^{\circ}C$. ANOVA analysis was carried out using the data of Seoul Metropolitan City in 1994 to check the robustness of the new standard level of Heat Health Watch Warning System from this study, in particular for mortality variable. The results reveal that the new standard specifies excess mortality well, showing significance level of 0.05 in the difference of excess mortality for each phase.

Usability Evaluation of the Touch Keys for the Smart Watch (스마트 워치 터치스크린에서의 터치 키에 대한 사용성 연구)

  • Kim, Su Young;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • The smart watch is the most popular wearable computing device because it takes a form of wristwatch. Many smart watches have adopted the touch screen interface due to the limited size of display. This paper focuses on touch key size and spacing that affect the usability about the touch key of smart watch. The experiments were made for four touch key sizes (width${\times}$height; $5{\times}5$, $5{\times}7$, $7{\times}5$, $7{\times}7mm$) and nine touch key spacing (vertical${\times}$horizontal; $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, $3{\times}3mm$). The completion time, error rate, control discomfort and identification discomfort were measured. The touch key size $7{\times}7$, $7{\times}5$ and the touch key spacing $3{\times}3$, $1{\times}3$ provided the best results in terms of the completion time and the control discomfort, while the square touch key ($7{\times}7$, $5{\times}5$) provided the best performance for the error rate measure. The result of this study can help ergonomically design the touch interface of the smart watch.

Distribution Characteristics and Background Air Classification of PM2.5 OC and EC in Summer Monsoon Season at the Anmyeondo Global Atmosphere Watch (GAW) Regional Station (안면도 기후변화감시소의 여름철 PM2.5 OC와 EC 분포 특성 및 배경대기 구분)

  • Ham, Jeeyoung;Lee, Meehye;Ryoo, Sang-Boom;Lee, Young-Gon
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.429-438
    • /
    • 2019
  • Organic carbon (OC) and elemental carbon (EC) in PM2.5 were measured with Sunset Laboratory Model-5 Semi-Continuous OC/EC Field Analyzer by NIOSH/TOT method at Anmyeondo Global Atmosphere Watch (GAW) Regional Station (37°32'N, 127°19'E) in July and August, 2017. The mean values of OC and EC were 3.7 ㎍ m-3 and 0.7 ㎍ m-3, respectively. During the study period, the concentrations of reactive gases and aerosol compositions were evidently lower than those of other seasons. It is mostly due to meteorological setting of the northeast Asia, where the influence of continental outflow is at its minimum during this season under southwesterly wind. While the diurnal variation of OC and EC were not clear, the concentrations of O3, CO, NOx, EC, and OC were evidently enhanced under easterly wind at night from 20:00 to 8:00. However, the high concentration of EC was observed concurrently with CO and NOx under northerly wind during 20:00~24:00. It indicates the influence of thermal power plant and industrial facilities, which was recognized as a major emission source during KORUS-AQ campaign. The diurnal variations of pollutants clearly showed the influence of land-sea breeze, in which OC showed good correlation between EC and O3 in seabreeze. It is estimated to be the recirculation of pollutants in land-sea breeze cycle. This study suggests that in general, Anmyeondo station serves well as a background monitoring station. However, the variation in meteorological condition is so dynamic that it is primary factor to determine the concentrations of secondary species as well as primary pollutants at Anmyeondo station.

IoT model to improve parent-child interaction -Focus on smart watch for kids- (부모-자녀 상호작용을 증진하는 IoT 모델 -유아용 스마트워치를 중심으로-)

  • Yee, Young-Hwan
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.6
    • /
    • pp.209-218
    • /
    • 2017
  • To propose a contents model for children's smart watch, this study interview 15mothers who have a child using smart watches. Most mothers purchase smart watches for children to warrant their security and manage their schedules, and they use them for sending a call or text to their children, tracking or managing children's location and schedule. Mothers were satisfied with a smart watch's function of communication and safety management, but dissatisfied learning-oriented contents and worrried about bad influenced on children development. Through in-depth interviews, this study propose a persona model for children's smart watch for enhancing parent-child interaction and physical cognitive language socioemotional convergence play contents.

Development of a Training Model for Electro-Technical Officers on Ships (선박 전자기관사를 위한 교육모델 개발)

  • RYU, Ki-Tak;LEE, Yun-Hyung
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.767-777
    • /
    • 2017
  • The purpose of this paper is to develope a training model and to make a syllabus for electro-technical officers(ETOs) on ship. In order to complete the purpose, firstly we study on qualification for electro-technical officers and also examine the foreign, domestic cases. Secondly, through the STCW convention and the IMO Model Course 7.08, we have compared the standards of competence for officers in charge of an engineering watch and ETO, and analyze the additional standards of competence to acquire the ETO's licenses. Finally, based on the results of this, we will suggest the development of a training model that officers in charge of an engineering watch must complete in order to obtain an ETO's license. This paper is expected to be useful in the educational institution preparing for training course.

A Study on Certification of Officers in charge of a Navigational Watch on Tug-barges

  • Park, Sung-Hyeon;Lee, Sang-Do
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.711-716
    • /
    • 2008
  • Marine accidents related to the tug-barges are frequent recently, such as oil spill caused by collision between oil tankers and tug-barges. There are many causes of these accidents, but poor working condition of operators takes up a considerable part of most causes. That is, the danger of accidents caused by fatigue accumulation exists in tug-barges of less than 200 gross tonnage engaged on near-coastal voyages or short shipping, because of the long-distance navigational watch by only one master. This paper aims to deduce problems of human element part out of the plan of sqfe navigation, and to propose legal amendments for preventing marine accidents by tug-barges.