• Title/Summary/Keyword: Wastewater effluent

Search Result 878, Processing Time 0.028 seconds

Recovery and Utilization of Proteins and Lipids from Washing Wastewater in Marine Manufacture by Isoelectric Point Precipitation Method 1. The Coagulation Treatment for Washing Wastewatfr of Minced Mackerel Meat (수산가공공장 폐액의 등전점 침전처리에 의한 유용성분 재회수 이용 1. 고등어 육 고기풀 제조시 발생되는 폐액의 처리장치 개발)

  • 서재수;조순영
    • KSBB Journal
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • A lot of water soluble proteins and lipids are released from minced mackerel meat and lost into the washing waste during the leaching process of Kamaboko or surimi manufacture. The removed proteins and lipids are not only an edible things but also a big burden for treating the wastewater. In order to recover the proteins from the effluent and to use as food stuff, the "pH-shifting" treatment, a modified isoelectric point precipitation method, was tried. This method is based on a myogen-aggregation phenomenon, which occurs when a solution of sarcoplasmic proteins is acidified or alkalified beyond the critical pH zone of 2∼3 or 12∼13 respectively and then neutralized. The maximum amount of precipitation was obtained by shifting the pH of the wastewater from original pH to isoelectric point (pH 4) or alkali pH 12 and then changing to neutral pH. The precipitates were easily collected by filteration or centrifuging at 10,000rpm. The oils which were only floating in the washing wastewater are easily recovered by seperating with oil separator after pouring. The recovered proteins were slightly denaturated during this pH shifting precipitation process, while the composition of amino acids was good balance as a food.

  • PDF

Application of Adsorption Characteristic of Ferrous Iron Waste to Phosphate Removal from Municipal Wastewater (폐산화철의 흡착특성을 이용한 도시하수내 인 처리)

  • Kim, Jin-Hyung;Lim, Chae-Sung;Kim, Keum-Yong;Kim, Dae-Keun;Lee, Sang-Ill;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • This study proposed the method of phosphate recovery from municipal wastewater by using ferrous iron waste, generated from the mechanical process in the steel industry. In the analysis of XRD, ferrous iron waste was composed of $Fe_3O_4$ (magnetite), practically with $Fe^{2+}$ and $Fe^{3+}$. It had inverse spinel structure. In order to identify the adsorption characteristic of phosphate on ferrous iron waste, isotherm adsorption test was designed. Experimental results were well analyzed by Freundlich and Langmuir isotherm theories. Empirical constants of all isotherms applied increased with alkalinity in the samples, ranging from 1.2 to 235 $CaCO_3/L$. In the regeneration test, empirical constants of Langmuir isotherm, i.e., $q_{max}$ (maximum adsorption capacity) and b (energy of adsorption) decreased as the frequency of regeneration was increased. Experiment was further performed to evaluate the performance of the treatment scheme of chemical precipitation by ferrous iron waste followed by biological aerated filter (BAF). The overall removal efficiency in the system increased up to 80% and 90% for total phosphate (TP) and soluble phosphate (SP), respectively, and the corresponding effluent concentrations were detected below 2 mg/L and 1 mg/L for TP and SP, respectively. However, short-circuit problem was still unsolved operational consideration in this system. The practical concept applied in this study will give potential benefits in achieving environmentally sound wastewater treatment as well as environmentally compatible waste disposal in terms of closed substance cycle waste management.

Bacterial Community Shift during the Startup of a Full-Scale Oxidation Ditch Treating Sewage

  • Chen, Yajun;Ye, Lin;Zhao, Fuzheng;Xiao, Lin;Cheng, Shupei;Zhang, Xu-Xiang
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.1
    • /
    • pp.141-148
    • /
    • 2017
  • The oxidation ditch (OD) is one of the most widely used processes for treating municipal wastewater. However, the microbial communities in the OD systems have not been well characterized, and little information about the shift of bacterial community during the startup process of the OD systems is available. In this study, we investigated the bacterial community changes during the startup period (over 100 days) of a full-scale OD. The results showed that the bacterial community dramatically changed during the startup period. Similar to the activated sludge samples in other studies, Proteobacteria (accounting for 26.3%-48.4%) was the most dominant bacterial phylum in the OD system, but its relative abundance declined nearly 40% during the startup process. It was also found that Planctomycetes proliferated greatly (from 4.79% to 13.5%) and finally replaced Bacteroidetes as the second abundant phylum in the OD system. Specifically, some bacteria affiliated with genus Flavobacterium exhibited remarkable decreasing trends, whereas bacterial species belonging to the OD1 candidate division and Saprospiraceae family were found to increase during the startup process. Despite of the bacterial community shift, the organic matter, nitrogen, and phosphorus in the effluent were always in low concentrations, suggesting the functional redundancy of the bacterial community. Moreover, by comparing with the bacterial community in other municipal wastewater treatment bioreactors, some potentially novel bacterial species were found to be present in the OD system. Collectively, this study improved our understandings of the bacterial community structure and microbial ecology during the startup of a full-scale wastewater treatment bioreactor.

Treatment of Refractory Organics in Dyeing Wastewater by Using Cell Immobilized Pellets (고정화담체를 이용한 염색폐수의 난분해성 유기물질 처리)

  • Han, Duk-Gyu;Bae, Woo-Keun;Cho, Young-Jin;Won, Ho-Shik;Lee, Yong-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.917-922
    • /
    • 2005
  • The wastewaters from textile and dyeing industries are difficult to treat due to its high pH, temperature, color intensity and non-biodegradable organic contents. This study investigated the removal of recalcitrant organics in a dyeing wastewater by using a packed bed reactor (PBR) that contained cell-immobilized pellets. The feed, obtained from an effluent of a biological treatment plant, had $SCOD_{Cr}$ of 330 mg/L and $SBOD_5$ of 20 mg/L on average. In immobilizing the cells to a Polyethylene Glycol(PEG) based medium, activated sludges from either a sewage treatment plant or an industrial wastewater treatment plant were used. When the empty bed contact time (EBCT) was above 8 hrs in the PBR, the $COD_{Cr}$ removal efficiency was over 50% and the $COD_{Mn}$ concentration was 72 mg/L or lower on average, which was substantially lower than the discharge standard of 90 mg/L. The results indicated that the optimum EBCT in the PBR was 8 hrs. The PBR with cell-immobilized pellets was effective as an advanced treatment process after an activated sludge process for treating dyeing wastewaters.

Lithoautotrophic Nitrogen Removal from Ammonium-rich Wastewater in Aerobic Upflow Sludge Bed(AUSB) Reactor (호기성 상향류 슬러지상 반응조를 이용한 고농도 암모늄 함유폐수의 독립영양 질소제거)

  • Ahn, Young-Ho;Choi, Hoon-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.852-859
    • /
    • 2006
  • The novel microbial process such as Anammox(anaerobic ammonium oxidation) and Canon(completely autotrophic nitrogen removal over nitrite) processes is promising biotechnology to remove nitrogen from ammonium-rich wastewater like anaerobic sludge digester liquid. In this research, a new Canon-type nitrogen removal process adopting upflow granular sludge bed type configuration was investigated on its feasibility and process performance, using synthetic wastewater and sludge digester liquids. Air as an oxygen source was provided in an external aeration chamber with flow recirculation. In the first experiment using the synthetic wastewater(up to 110 mg $NH_4$-N $L^{-1}$), the ammonium removal was about 95%(92% for T-N) at effective hydraulic retention time(HRT) for 3.8 days. In the second experiment using the sludge digester liquids($438{\pm}26$ mg $NH_4$-N $L^{-1}$), the total nitrogen removal was $94{\pm}1.7%$ at HRT for 5.4 days and $76{\pm}1.5%$ at HRT for 3.8 days, respectively. Little nitrite and nitrate were observed in the effluent of both experiments. The process revealed quite a lower oxygen($0.29{\sim}0.59$ g $O_2$ $g^{-1}N$) and less alkalinity($3.1{\sim}3.4$ g $CaCO_3$ $g^{-1}N$) consumption as compared to other new technology in microbial nitrogen removal. The process also offers the economical compact reactor configuration with excellent biomass retention, resulting in lower cost for investment and maintenance.

Removal of Endocrine Disrupting Chemicals in Wastewater by Nitrifying Sludge (질산화 슬러지에 의한 폐수 중의 내분비계 장애물질 제거)

  • Lim, Kyoung Jo;Hong, Soon Ho;Chung, Jin Suk;Yoo, Ik-Keun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.775-780
    • /
    • 2009
  • The efficacy of nitrifying sludge existed in biological nutrient removal process was examined for possible removal of endocrine disrupting chemical(EDC) in the effluent of wastewater treatment plant. Some of ammonia oxidizing bacteria causes ammonia oxidation mediated by ammonia monooxygenase(AMO) activity, which has low substrate specificity resulting in cometablic degradation of several chemicals. In this study, the removal of three model EDCs such as bisphenol A(BPA), nonylphenol(NP) and dibutyl phthalate(DBP) was studied in batch cultures using nitrifying sludge, BOD-oxidizing sludge with low nitrifying activity, and sterilized sludge. Nitrifying sludge showed higher initial removal rates in all batches of three EDCs when it was fed with ammonium as an energy source. The acclimation time was required for the removal of EDCs in batches using BOD-oxidizing sludge or nitritefed nitrifying sludge. That retardation seemed to attribute to the slow growth of cells using the EDCs while ammonium-fed nitrifying sludge could degrade EDCs through simultaneous cooxidation with ammonia oxidation. Sterilized sludge was also tested under the same conditions in order to find the contribution of physical adsorption to the removal of EDCs. About 10~20% of initial EDCs dose was removed when using sterilized sludge. Thus the biological activity is likely to play major role for the degradation of BPA, NP, and DBP rather than the physical adsorption from wastewater.

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

Eutrophication and Water Pollution Characteristics of the Kyongan Stream to Paltang Reservoir (경안천${\sim}$팔당호의 부영양화와 수질오염 특성)

  • Cho, Joo-Lae;Hwang, Soon-Jin;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.4 s.92
    • /
    • pp.387-394
    • /
    • 2000
  • Water pollution characteristics were investigated in the Kyongan stream and major inlet parts of Paltang Reservoir from April to July, 2000. Water quality in the Kyongan stream was extremly deteriorated by treated wastewater discharge at near sewage wastewater treatment plant (SWTP) located in the upstream, and it is likely to influence eutrophication of the lower part of the stream. Water quality of the Kyongan stream showed a typical hypertrophic condition. Influxed concentrations with $NH_4$ and SRP into the main stream from SWTP were declined precipitously as water flowed toward the lower part of the stream, and chlorophyll- a explosively increased in the midstream. Average concentrations of $NH_4$, SRP and chlorophyll-a in the main stream were $1,343\;{\mu}g\;N/l$, $1,779\;{\mu}g\;P/l$ and $188\;{\mu}g\;l$, respectively. Particularly, phosphorus load was very high, and its influence on the algal growth stimulation was remarkable. In comparison with the water quality inflowing into Paltang Resevoir, pollution status of the Kyongan stream was more worse than that in the Pukhan River and the Namhan River. The results of this study indicate that the management of point source, SWTP effluent, is urgent to mitigate eutrophication of Paltang Reservoir, and requires further necessary controls of inorganic phosphorus loading.

  • PDF

Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric (부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Park, Ji-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

Sampling Survey of Hazardous Water Pollutants in Industrial Wastewater Treatment Plants (산업단지 폐수종말처리장의 특정수질유해물질 유입 및 방류 현황조사)

  • Park, Soo-Hyung;Jung, Jin-Young;Kim, Jaehoon;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.590-595
    • /
    • 2015
  • Sampling campaigns were conducted for hazardous chemicals and heavy metals in influents and effluents of industrial wastewater treatment plants (WWTPs) in Korea for best management practices (BMPs) of those pollutants through the plants and the receiving water bodies. Twenty seven WWTPs, receiving wastewater from industrial complexes and treating more than $2,000m^3/day$, were selected for the sampling campaign. Influents and effluents of each WWTPs were sampled once a month (total three times per plant) between July and September, 2012, and analyzed for 22 hazardous water pollutants among 28 regulated for effluents limits in Korea. Concentrations of mercury, arsenic, 1,1-dichloroethylene, and benzene in the influents were relatively higher; concentrations of mercury and arsenic in effluents were relatively higher than those of other pollutants. Most of the hazardous chemicals and heavy metals were removed (including phase transfer) more than 60% through the treatment processes except for selenium (30% removal) and 1,4-dioxane (18% removal).