• 제목/요약/키워드: Wastewater Reclamation and Reusing System

검색결과 5건 처리시간 0.018초

유가공폐수 처리수의 재이용에 관한 연구 (A study on the Reclamation and Reuse of Milk Manufacturing Wastewater)

  • 곽필재;우달식;남상호
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.111-119
    • /
    • 1997
  • We met the continued population growth, contamination of both surface and groundwaters, deficiency of water resources, and increase of water demand. Wastewater reclamation and reusing system are important facilities in water resources planning aspect. The required water quality for reclamed wastewater varies with each application. This study was conducted to examine the possibilities of the wastewater reclamation and reusing on milk manufacturing wastewater. Biofiltration could reduce the COD$_{Cr}$, NH$_{3}$-N. Turbidty was reduced highly by coagulation. In conclusion, we identified the possibilities of wastewater reclamation and reusing on milk manufacturing wastewater's by biological activated carbon filter.

  • PDF

경제성분석을 이용한 접촉폭기방식 중수도의 설치규모분석에 관한 연구 (Study on Installation Capacities of Wastewater Reclamation and Reusing System Applying to Contact Aeration Process using Cost-benefit Analysis)

  • 남영우;박태욱
    • 대한환경공학회지
    • /
    • 제22권11호
    • /
    • pp.1945-1954
    • /
    • 2000
  • 접촉폭기방식 중수도를 설치할 때 발생하는 비용과 편익의 현재가치를 이용한 경제성분석을 통해 서울특별시와 6개 광역시의 지역별 설치규모분석을 수행하였다. 사적 편익을 고려한 접촉폭기방식 중수도의 설치규모는, 가정용일 경우, 부산은 일일 중수사용량이 $500m^3$, 대구는 $1,000m^3$ 및 광주는 $2,000m^3$ 이상일 때 경제성이 있는 것으로 나타났다. 그러나 서울, 인천, 대전 및 울산은 $3,000m^3$ 이상에서도 경제성이 없어 단독공급 방식보다는 대단지 공동주택의 지역순환방식으로 시설을 설치해야 할 것으로 판단된다. 업무용의 경우 서울, 부산 및 광주는 일일 중수사용량이 $100m^3$ 이상, 대구, 인천, 대전 및 울산은 $300m^3$ 이상일 때 경제성이 있다. 영업용의 경우 서울, 부산, 대구, 광주, 대전 및 울산은 중수사용량이 $100m^3$ 이상이고 인천은 $300m^3$ 이상일 때 경제성이 있는 것으로 나타났다. 사회적 편익을 고려한 접촉폭기방식 중수도의 설치규모는 일일 중수사용량이 $100m^3$ 이상일 때 경제성을 갖는 것으로 나타났다.

  • PDF

C-HMI 기반의 원격지 중수도 설비 실시간 제어와 모니터링 구현 (Implementation of C-HMI based Real-time Control and Monitoring for Remote Wastewater Reclamation and Reusing System)

  • 이운선;박만곤
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.717-722
    • /
    • 2013
  • The wastewater reclamation and reusing system has been rising as an alternative of water resource exhaustion that the whole world is experiencing. In order to be able to bring about improvement of the existing wastewater reclamation and reusing system, this research has developed of Conversion-Human Machine Interaction (C-HMI) based real-time control and monitoring system such as a sensor module and gate module, web monitoring system. This system was communication almost-error-free in various environment and situation. As a result, we have achieved our goal that has to doing work correctly as a sensor and gateway module that communication error is less than 0.2% throughout the embodied system and add that it can be easily controled and configured as an interface equipment to a complex sensor of water quality. According to this, the construction of a database capable of analyzing and assessing collection, storage and various elements of reliable water quality and flow rate data can be possible.

하수처리수를 활용한 중수도의 도입방안 연구 (A study on the device introduction of wastewater reclamation system a treated sewage)

  • 박노삼;박상현
    • 한국산업융합학회 논문집
    • /
    • 제2권2호
    • /
    • pp.23-33
    • /
    • 1999
  • After studying several methods of the application a device of a treated sewage in anticipation of the future shortage of the duty of water, we could have some conclusion as the following : Advanced treatment systems arc essential prerequisites in reusing a treated sewage. And in a short term, the application of reusing a treated sewage should go first to new building areas near the sewage but for the long run, it should cover the whole area of Taegu, it is desirable that the pipe line networks which include dual water systems as well as water supply should be spread throughout the whole city. The city authorities have to make every effort to step up publicity activities on this plan to all the citizens and building owners to steadily carry out this project and encourage private constructors to participate with the help of SOC. And for the long run, it is desirable that the application of reusing a treated sewage should be obligatory.

  • PDF

고정상 담체와 은나노 모래여과를 이용한 이중 공정에서 처리수의 중수도 활용에 관한 연구 (A Study on the Utilization of Effluent Treated by Double Process Using Fixed-media and Sand Filter Coated by Nano Silver for Wastewater Reclamation and Reusing System)

  • 선용호
    • KSBB Journal
    • /
    • 제21권4호
    • /
    • pp.317-323
    • /
    • 2006
  • 본 연구는 다가올 물 부족에 따른 하나의 대안으로서 중수도 시스템에 초점을 맞추어, 생활오수를 이용하여 혐기/무산소/호기조의 $A^2O$ 생물막 공법으로 구성된 상향류식 고정상 담체 반응기로 처리한 오수를 하향류식 은나노 모래여과 반응기에 다시 연속 통과시켜 이중 처리하여 얻은 처리수를 중수도에 활용이 가능하지에 대하여 연구하였다. 이중 공정 후 배출수의 pH는 $7.39{\sim}8.06$(평균 7.84) 범위이었고, $COD_{Mn}$$8{\sim}18mg/L$(평균 12.1 mg/L), $BOD_5$$2.1{\sim}10mg/L$(평균 4.9 mg/L)로 중수도 수질 기준에 적합하였다. SS는 $3{\sim}9mg/L$의 범위로 평균 농도가 4.95 mg/L를 나타내면서 SS 제거율이 94.8%로 대부분 법적 기준치 5 mg/L 이하로 처리되어 가능성을 보여 주었다. 대장균군 수의 평균 제거율이 99.1%이었으며, 배출수의 평균 대장균 군수는 65 MPN/100mL이 검출되었으나 중수도 수질 기준에는 불검출로 되어 있으므로 완벽한 제거를 위해서는 0.2 mg/L 이상의 결합잔류염소의 양을 고려한 염소 처리를 하여야 한다. SEM 사진으로부터 은모래 표면에서는 박테리아가 존재하지 않음을 알 수 있었다. 이 외에 중수도 수질 기준에 포함될 가능성이 있는 총질소 및 총인의 제거율은 각각 50.3%와 27.2%이었다.