• Title/Summary/Keyword: Waste water treatment facility

Search Result 50, Processing Time 0.023 seconds

Evaluation of Carrying Capacity and Sustainability of Jeju Island using Onishi Model (Onishi Model을 이용한 제주도 기반시설 환경용량 산정 및 지속가능성 평가)

  • Park, Jinseon;Kim, Solhee;Kim, Yooan;Hong, Sewoon;Suh, Kyo
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.2
    • /
    • pp.95-106
    • /
    • 2020
  • The Onishi model is an objective indicator which can be used to evaluate the relevance of city environmental management in regard to the capacities and processing status of existing urban infrastructure. This study is to analyze the facility carrying capacity and processing status of Jeju Island, a famous tourist site in South Korea. General variables covered by the Onishi model are considered, including water supply, wastewater treatment, waste disposal, and air pollution. Furthermore, the facility carrying capacities for transportation, such as airports and ports, as well as accommodations are assessed as variables pertinent to the characteristics of Jeju island. With the annual number of tourists exceeding that of residents on the island, more facilities for sewage treatment and waste disposal are required. Furthermore, transportation and accommodations used by tourists have already exceeded their capacity. For the future sustainability of Jeju Island, a plan will be needed for adjusting the volume of tourists based on the capacity of each relevant facility.

Treatment of residues of excavated carcasses burials (가축매몰지 소멸시 잔존물 처리방안)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.269-277
    • /
    • 2018
  • Burials for the rapid disposal of carcasses have diverse and profound effects on the rural living condition, natural environment, and local economy throughout construction, management and final destruction of burials. In this study, possible residue excavated from standard burials, storage using FRP (Fiberglass Reinforced Plastic) tanks, and microbial-treated burials are characterized as carcasses, contaminated soil by leachate, and wasted plastic film. Treatment technologies for volume reduction of the residue including composting, rendering, and thermal hydrolysis were investigated. If the solid and liquid residues generated during volume reduction treatment are directly transferred to the environmental facilities, it may cause disorder due to high concentrations of organics, antibiotics, and lipid. Benefits and drawbacks of composting as a volume reduction techniques are extensively investigated. We also discussed that proper treatment of excavated soils and the reusing the treated soil as agricultural purpose. For the protection of public health and worker's hygiene, treatment criteria including produced residue qualities, and quality standards for the treated soil as agricultural use are required. In addition, Scientific manual for the proper treatment of residues is required. It is necessary to consider the establishment of a pretreatment facility to the occurrence of large-scale residue treatment.

Characterization of Odorous Elements from Emission Sources in Chungju (충주시 악취발생원으로부터 배출되는 악취원인물질 특성 분석)

  • Cho, Byung-Yeol;Jo, Young-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • The emission characteristics of odorous compounds discharged from the major environmental treatment facilities in Chungju were closely investigated by an ammonia passive sampler and by analyzing a questionnaire of the public complains. Amongst the four major emission sources, the manure treatment facility showed the highest concentration. The major components were sulfur compounds including H$_2$S, tri-methyl amine, and aldehydes. The foodwaste treatment processes releases sulfur compounds and aldehydes. Municipal waste water treatment facility emits a high concentration of acetaldehyde. It was found that the perceived odor level depends on the meteorological condition, and the odor intensity was higher at midnight than daytime.

Development of Ultrasonic Multi-Beam Sludge Meter For Effluent Facilities Automation (정수장에서 배출수 공정 자동화를 위한 초음파 다중빔 슬러지 농도계 개발)

  • Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2313-2321
    • /
    • 2014
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical input. This study has been prepared for improving efficiency of operation on sludge processes and to establish a basic for factory automation by accuracy improvement and problem solution of sludge concentration meter. The concentration meter's accuracy and stability is improved by applying multi-beam sensors and minimum deviation linear average filtering. Furthermore maintenance without cut-off of water in sludge operation is possible by detachable sensors. The performance of multi-beam concentration meter has been variously verified by the pilot plant experiment.

The Treatment of Organic Wastewater using Thermophilic Oxic Process (고온호기발효공법을 이용한 유기성폐수의 처리)

  • 유순주;류재근;서윤수;도삼유평
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.13-22
    • /
    • 1995
  • Most of small- scale livestock facility have difficulties to treat organic wastewater by activated sludge process as distinguished feces and urine. The organic wastewater discharged have characteristics of slurry, high concentration of BOD, 55 etc. This study was performed to estimate suitable condition for the application of packing materials, air flow, pollutant load and so on as important parameter to treat organic wastewater by thermopile oxlc process. As a result obtained at this experiments the most suitable condition for BOD load, air flow indicate 3.0kg · m$^{-3}$ day$^{-1}$,50 ∼ 100L· min$^{-1}$ m$^{-3}$, respectively, and we knew that it was necessary to add waste contained high calories to degrade about 80% of pollutant among waste- water. It showed that plastic material can be used as packing media because it can be provided as inhabitation for microorganism owing to intensity of material and characteristic of keeping moisture.

  • PDF

Composting using the Lime Stabilization of Dewatering Sludge from Centralized Swine Wastewater Treatment Facility (석회안정화 방법을 이용한 돈사분뇨공공처리시설에서 발생하는 탈수슬러지의 퇴비화)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.687-694
    • /
    • 2006
  • Dewatering sludge using inorganic chemicals with polymer has been evaded for reuse on account of the risks of high heavy metals contained and soil acidification. Composting feasibility of coagulation & dewatering sludges produced from livestock waste treatment plant was investigated. The results of analysis prove that dewatering sludge is valuable matter with suitable elements for composting if high quality ferric chloride ($FeCl_3$) is used for coagulation & dewatering process. In pot-cultivation of harvestes, using effects of dewatering sludge improved with lime treatment was very effective. The results of pot-cultivation proved that harms of crops according to different acid tolerances were not detected. But it was not applied to crops with weak acid tolerance or greenhouse for free from gas damage. Also, Further studies and monitorings are necessary to use sludges because results of pot-cultivation were generated differently by characteristics of soil, nutrient demand of plants, mature degree of sludge, consecutive cultivation and etc.

Determination of Major Reduced Sulfur Gases Emitted from Wastes Stored in Environmental Facility Using GC/FPD (GC/FPD를 이용한 환경기초시설 폐기물의 대기중 황계열 악취물질 배출특성에 관한 연구)

  • Lee, Taeyoon;Lee, Jeakeun;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • With the economic development of Korea, sewage treatment facilities and waste food treatment facilities have been steadily increased. These facilities have positive effects such as the conservation of the water resources quality and waste food recycling while they also affect the neighborhood life with severe odor problems. Therefore, it was first collected sludge samples from 5 sewage treatment facilities and 5 waste food treatment facilities where the amounts of waste produced from above sites are relatively immense in Busan and estimate the $H_2S$ emission rates. Then it was selected 1 sample which has the highest emission rate of $H_2S$. Using flux chamber and GC/FPD analyses, it was tried to quantify the emitted amount of sulfonic gas concentration under anoxic condition. The sludge sample obtained from Noksan sewage treatment facility has the highest emission rate of $H_2S$. This sample contained 156.18 mg/kg $H_2S$. The odor compounds were analyzed using GC/FPD and the concentrations were converted to odor quotient. Among odor compounds the ratio of $CH_3SH$ (methylmercaptan) for the total odor quotient was 47.3% and considered to be the main odor compound in the sample.

  • PDF

Ecotoxicity Assessment for Livestock Waste Water Treated by a Low Impact Development(LID) Pilot Plant (파일럿 규모의 LID공법을 적용한 축산폐수 처리수에 대한 생태독성 평가)

  • Park, Da Kyung;Chang, Soon-Woong;Choi, Hanna
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.662-669
    • /
    • 2017
  • This study evaluated the ecotoxicological properties of livestock waste water treated by a LID (Low Impact Development) system, using a mixture of bio-reeds and bio-ceramics as suitable bed media for a subsequent treatment process of a livestock wastewater treatment plant. The relationship between the pollutant reduction rate and the ecotoxicity was analyzed with the effluents from the inlet pilot plant, with vegetated swale and wetlands and the batch type of an infiltration trench. Each pilot plant consisted of a bio process using bio-reeds and bio-ceramics as bed media, as well as a general process using general reeds and a bed as a control group. The results indicated that, after applying the HRT 24 hour LID method, the ecotoxicity was considerably lowered and the batch type pilot plant was shown to be effective for toxicity reduction. The LID method is expected to be effective for water quality management, considering ecotoxicity by not only as a nonpoint source pollution abatement facility but also, as a subsequent treatment process linked with a livestock manure purification facility. It is necessary to take the LID technic optimization study further to apply it as a subsequent process for livestock wastewater treatment.

ELECTROCHEMICAL PROCESSING OF USED NUCLEAR FUEL

  • Goff, K.M.;Wass, J.C.;Marsden, K.C.;Teske, G.M.
    • Nuclear Engineering and Technology
    • /
    • v.43 no.4
    • /
    • pp.335-342
    • /
    • 2011
  • As part of the Department of Energy's Fuel Cycle Research and Development Program an electrochemical technology employing molten salts is being developed for recycle of metallic fast reactor fuel and treatment of light water reactor oxide fuel to produce a feed for fast reactors. This technology has been deployed for treatment of used fuel from the Experimental Breeder Reactor II (EBR-II) in the Fuel Conditioning Facility, located at the Materials and Fuel Complex of Idaho National Laboratory. This process is based on dry (non-aqueous) technologies that have been developed and demonstrated since the 1960s. These technologies offer potential advantages compared to traditional aqueous separations including: compactness, resistance to radiation effects, criticality control benefits, compatibility with advanced fuel types, and ability to produce low purity products. This paper will summarize the status of electrochemical development and demonstration activities with used nuclear fuel, including preparation of associated high-level waste forms.

Determination of Self-Disposal date by the Analysis of Radioactive Waste Contamination for 1131I Therapy Ward (131I 치료입원실 폐기물 방사능 오염도 분석 및 자체처분가능일자 산출)

  • Kim, Gi-sub;Jung, Haijo;Park, Min-seok;Jeon, Gjin-seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.3-6
    • /
    • 2013
  • Purpose: The treatment of thyroid cancer patients was continuously increased. According to the increment of thyroid cancer patients, the establishment of iodine therapy site was also increased in each hospital. This treatment involves the administration of radioactive iodine, which will be given in the form of a capsule. Therefore, protections and managements for radioactive source pollution and radiation exposure should be necessary for radiation safety. Among the many problems, the problem of disposing the radioactive wastes was occurred. In this study, The date for self-disposal for radioactive wastes, which were contaminated in clothes, bedclothes and trash, were calculated. Materials and Methods: The number of iodine therapy ward was 15 in Korea Institute of Radiological Medical and Sciences. Recently, 8 therapy wards were operated for iodine therapy patients and others were on standby for emergency treatment ward of any radiation accidents. Radioactive wastes, which were occurred in therapy ward, were clothes, bedclothes, bath cover for patients washing water and food and drink which was leftover by patients. Each sample was hold into the marinelli beaker (clothes, bedclothes, bath covers) and 90 ml beaker (food, drink, and washing water). The activities of collected samples were measured by HpGe MCA device (Multi Channel Analysis, CANBERRA, USA) Results: The storage period for the each kind of radioactive wastes was calculated by equation of storage periods based on the measurement outcomes. The average storage period was 60 days for the case of clothes, and the maximum storage period was 93 days for patient bottoms. The average storage period and the maximum storage period for the trash were 69 days and 97 days, respectively. The leftover foods and drinks had short storage period (the average storage period was 25 days and maximum storage period was 39 days), compared with other wastes. Conclusion: The proper storage period for disposing the radioactive waste (clothes, bedclothes and bath cover) was 100 days by the regulation on self-disposal of radioactive waste. In addition, the storage period for disposing the liquid radioactive waste was 120 days. The current regulation for radioactive waste self-disposing was not suitable for the circumstances of each radioactive therapy facility. Therefore, it was necessary to reduce the leftover food and drinks by adequate table setting for patients, and improve the process and regulation for disposing the short-half life radioactive wastes.

  • PDF