• Title/Summary/Keyword: Waste landfill site

Search Result 200, Processing Time 0.028 seconds

Development of Optimal Treatment Process Train of Leachate from Industrial Waste Disposal Site

  • Han Gee Baek;Choi Kwang Soo;Min Man Gi;Han Young Hwan;Im Jung Hoon;Lee Hae Goon;Choi Myung Won;Kim Chang Won;Park Dong Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.2
    • /
    • pp.115-121
    • /
    • 1998
  • Train of chemical and biological processes was investigated to treat leachate from industrial waste landfill. Organics and nitrogen concentrations of landfill leachate studied in this research were high and their BOD/COD ratio was 0.3. Biological process should be combined with chemical process for optimum treatment of leachate. PAC(Polyaluminium chloride) was the best coagulant among three chemicals tested, and the optimum condition of PAC coagulation was pH 6 and 1,250 mg/L of dosage. When SBR was operated for simultaneous removal of organics and nitrogen, removal efficiency of COD and T-N reached over $82\%,\;71\%,$ respectively and time distribution of 2/4/2/1 was most effective for one cycle of anoxic/aerobic/anoxic/aerobic.

  • PDF

The characteristics of leachate migration and corrosivity in municipal wastefills at seaside (해안 도시폐기물 매립지의 침출수 이동 특성 및 부식성)

  • Jang, Yeon-Su;Jeong, Ha-Ik;Kim, Jin-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.12a
    • /
    • pp.33-66
    • /
    • 1992
  • Recently, waste landfills built on seashores have been increased because of the easy availability of broad area near the urban communities. To evaluate the performance of the marine clay landfill liner numerical contaminant transport analyses are performed by selecting the typical section of a waste landfill built on seashores and using hydraulic conductivity data obtained from the site. Also, the laboratory electrical resistivity test and the in-situ corrosion test are performed in order to analyze the influence of the soil and leachates composing the landfills on the construct ion materials. From the results of contaminant transport analyses, it is shown that the leachates can be migrated faster through narrow pervious channels than the wide homogeneous pervious tedium and the importance of good quality barriers to prevent the contaminant migration is recognized. In the laboratory electrical resistivity test all the earth materials except the cover soils saturated with distilled water have small resistivities, which shows a high potential of corrosivity of soils composing landfills. However, the degree of corrosion of specimens buried in the landfills was not so severe except the zinc and carbon steel specimens. This apparently conflict results present the necessity of the investigation of other major factors and the long term in-situ corrosion test.

  • PDF

Remote Sensing and GIS for Waste Disposal Site Selection in the Kathmandu Valley: A Case Study of Taikabu Area

  • Tuladhar, Ganga B.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.933-935
    • /
    • 2003
  • Geo-scientifically viable, environmentally suitable, and socially acceptable sanitary landfill sites are very limited in the Kathmandu Valley and is confronted with the burning problem of safe disposal of urban waste. This paper deal with the evaluation and assessment of its interface, following the major criteria defining suitable geological barrier, Cation Exchange Capacity and other necessary physical parameters with the optimum utilization of remotely sense data along with GIS techniques. The study revealed one of the most viable sites at the flat land of natural depression of Taikabu area and has potential to serve all the municipalities of the Kathmandu Valley.

  • PDF

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.

Studies on the Geological Environment of the Nanjido Waste Disposal Site: Gravity and Magnetic Investigations (난지도 매립지 및 그 주변의 지질환경 연구: 중력 및 자력탐사)

  • Kwon, Byung-Doo;Kim, Cha-Seop;Chung, Ho-Joon;Oh, Seok-Hoon
    • Economic and Environmental Geology
    • /
    • v.28 no.5
    • /
    • pp.469-480
    • /
    • 1995
  • Gravity and magnetic surveys were carried out to investigate the three-dimensional configuration and characteristics of the landfills at Nanjido waste disposal site. For terrain correction and three-dimensional density inversion of gravity data an algorithm, which calculates the gravity effect of a three-dimensional body by using the solid angle method, is developed. This algorithm has been proved to give more accurate terrain correction values for the small survey area having varied topography like Nanjido site as compared with widely used methods such as Hammer's method and multiquadric equation method. Density inversion of gravity anomaly data gives very useful information about the lateral and vertical variation of the landfills, which can be used to discriminate the kinds of wastes. The average density of filled materials appears to be $1.7\;g/cm^3$ which is much higher than the value $(0.8\;g/cm^3)$ estimated by Seoul City. The lateral variation of density shows high correlation with the pattern of ongoing depression of the landfills. The northern region of the landfill no. 1, which shows low density and high depression, is closely associated with the industrial waste and sludge filled area. The magnetic anomaly data provide information about relative concentration of magnetic materials, which is also very useful to investigate characteristics of the fills. Several high positive anomaly regions on the reduced-to-pole magnetic anomaly map are appeared to be associated with the industrial waste fills, but certain industrial waste fills show low negative anomalies. This kind of magnetic information can be used in selecting drilling locations over landfills away from buried metal products during the stabilization process.

  • PDF

Effects of Elutriating Rates for Elutriated Acid Fermentation of Food Waste (음식물쓰레기 세정산발효공정에서 세정율의 영향)

  • Kwon, Koo-Ho;Lee, Sang-Hyub;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.201-205
    • /
    • 2008
  • The korean government started to ban the sanitary landfill of food wastes as of 2005. The radical change of policy is primarily due to the limited landfill site, but aimed to promote not only to reduce the food waste production but also to enhance the reuse and recycle. The performance of elutriated acid fermentation to evaluate the effects of elutriating ratios was investigated. The fermenters were operated with elutriating water to food waste volumetric ratio of 2, 1, 0.5 and 0.25. Initial pH of elutriating water was set for 9 based on the pH effects study. The cumulative amounts of SCOD production rate were $0.34gSCOD/gVS_i$, $0.45gSCOD/gVS_i$, $0.26gSCOD/gVS_i$ and $0.28gSCOD/gVS_i$ with the ratios of 2, 1, 0.5 and 0.25, respectively. The cumulative productions of VFAs were 0.12 gVFAs as $COD/gVS_i$, 0.28 gVFAs as $COD/gVS_i$, 0.21 gVFAs as $COD/gVS_i$ and 0.14 gVFAs as $COD/gVS_i$ with the ratios of 2, 1, 0.5 and 0.25, respectively. The volume reduction were 58%, 52%, 45% and 47% with the ratios of 2, 1, 0.5 and 0.25, respectively.

Sorption Equilibria and Transport of Gaseous Chlorinated Organic Solvent in Wet Solid Waste Layer (도시고형폐기물(都市固形廢棄物) 및 토양층(土壤層)에 있어서 비(非)이온성(性) 유해유기화학물질(有害有機化學物質)의 거동(擧動)에 관한 연구(硏究) (습윤고형물폐기물층(濕潤固形物廢棄物層)에 있어서 기체상(氣體相) 유해유기염소화물질(有害有機鹽素化物質)을 주대상(主對象)으로))

  • Lee, Donghoon;Tanaka, Nobutoshi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.2
    • /
    • pp.9-23
    • /
    • 1993
  • Emission of hazardous and volatile organic chemicals from solid waste landfill site was become to important issue because of environmental pollution and health risk by such chemicals. Laboratory batch and continuous experiments were conducted respectively to elucidate isothermal sorption behaviors and transport phenomena(by gas through unsaturated solid waste layer) in wet solid waste-gas system. Source separated and size reduced refuse(bulky waste) and incinerated ash were used after controlling water content, and trichloroethylene(TCE) was chosen among many such chemicals because of it's generality among those man-created pollutants. Isothermal TCE sorption equilibria wet solid waste-gas system can be described in linear equation and partition coefficient in this system can be estimated approximately by the simple equation derived from schematic structure of the system. Transport equation modified by instantaneous equilibrium sorption fraction and kinetic sorption rate(overall mass transfer capacity coefficient) simulated well the column experiment results.

  • PDF

An Evaluation of Interface Shear Strength between Geosynthetic Clay Liner and Geomembrane (토목섬유 점토 차수재(GCL)와 지오멤브레인(GM)의 접촉 전단강도 평가)

  • 서민우;김동진;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.137-146
    • /
    • 2002
  • Geomembrane, compacted clay liner, and geosynthetic clay liner (GCL) are widely used to prevent leachate from leaking to adjacent geo-environment at a municipal solid waste (MSW) landfill. Interface shear strength between GCL and geomembrane installed at a landfill side slope is important properties for the safe design of side liner or final cover systems. The interface shear strength between two geosynthetics was estimated by a large direct shear test in this study. The shear strength was evaluated by the Mohr-Coulomb failure criterion. The effects of normal stress, hydration or dry condition, and a hydration method were investigated. The test results show that the interface shear strength and shear behavior varied depending up on the level of normal stress, the type of geosynthetic combinations, and a hydration method. When GCLs were sheared after being hydrated under 6kPa loading, the results were consistent with those published by other researchers. Summaries of friction angles, normal stress and hydration condition is presented. These friction angles could be used as a reference value at a site where similar geosynthetics are installed.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Development of DHLT Joint for Vertical Cutoff Walls in Offshore Waste Landfill Site (해상처분장 연직차수공을 위한 DHLT 이음부의 개발)

  • Hong, Young-Ho;Lee, Jong-Sub;Lee, Dongsoo;Chae, Kwang-Seok;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.3
    • /
    • pp.43-56
    • /
    • 2018
  • Vertical cutoff walls such as steel pipe sheet piles (SPSPs) have been commonly applied for the construction of the offshore waste landfill site. Because the SPSPs are sequentially installed by connecting their joints to those of adjacent piles, their mechanical stability should be ensured against the inherent external forces on the sea. The objective of this study is to evaluate the structural performances of the newly developed types of SPSP joint compared with those of other joint types. The problems of the traditional SPSP joints are investigated, and an advanced joint shape of SPSP, which is named double H with L-T (DHLT) joint, are designed for improving the constructability and maintenance. Full-scale models of the DHLT joint are manufactured, and then its joint areas are filled with grout material. After 28 days of curing time, compressive and tensile strength tests were performed on the joint models and the test results were compared with those of the traditional joints. Experimental results show that the structural capacities of the DHLT joint models are lower than those of traditional joints due to the influence of grout and steel members. In the cases of the compressive strength test, especially, bending occurs on steel H-beam with no distinct cracks in grout due to the asymmetrical structure of joint which has no reaction force. This study shows that the performance of the SPSP joint can be improved by considering the influence factors on the structural capacities estimated by the experimental tests.